Enter the code USA15 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on July 1 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Ref/frig not cooling
Removed the 4 screws holding the back panel in freezer compartment and then removed panel. Removed the 4 screws holding defrost heater and removed it. The replacement parts fit perfect , plug the new part in and bingo my frig is operating like a new one. Took about 15 minutes to make the repair. Took longer to defrost the ice buildup on the coils ( 1hr ) than to do the repair (15 min). I can't believe i would have been paying an appliance repairman to hold a hair dryer for an hour. Your diagrams showing where the various parts are located on the appliance are invaluable. Would recommend PartsSelect to anyone and I am sure that I will be ordering parts for my other appliances as needed. Thanks
First I turned the refrigerator and water line off. Then moved to the freezer section, followed the directions, removed the two screws. Directions state to not remove them but I had to in this case. Unplugged the ice maker and removed it from the freezer. I installed the two mounting screws then tried to plug the electrical connection back in but had to use the adaptor cord furnished in the kit. The cord was a little long but I tucked it in and mounted the ice maker. Turned it on then turned the refrigerator and water back on and in a few hours had ice! Very easy to do!
Twice I ordered the oven light bulb & each time the light bulb was defected
I had to call for a appointment for repair with GE Appliance because I thought then it . .was something electrical. The technician came out & checked everything out, turned out it was not electrical, The technician went out to his truck got a light bulb from his truck, put it in & it worked. It cost me $121.00 for trip charge from GE appliance for a light bulb that worked, your light bulbs were defective twice. Very disappointed with your products, cost me alot of money for a good light bulb thru GE appliance
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapped the new switch into place.
First turn off the power, remove the ice tray, remove the two screws holding the ice maker to the side of the freezer, use the screw driver to gently open the electrical clip for the power cord inside the freezer, remove the complete unit from freezer, bend the old stripper from the holding pin- it is flexible- it will bend, replace the new stripper on the holding pin and bend into the slot to hold it firmly, no water will come out from the fill cup into the freezer, plug in the power cord, mount back to side of freezer, you are done.
Freezer would not auto defrost. Food side would be warm.
Your customer installation comments were very helpful. After unplugging the unit, I took out all the freezer shelfs and the back panel (4 screws). I hadn't realized the coils were also covered in solid ice. It took awhile to defrost with a hair dryer, and I needed to use more than one towel to soak up the melting ice. Locating and splicing in the new thermostat was very easy. I used "cold weather" electrical tape to splice the wires back together. After reassembling the back panel and shelfs, I snapped in a new light shield that had been broken for awhile. It's been over a week now, and I do not see any problems. Overall, it was a easy fix. Just took a little time to defrost the coils.
remove lower back cover - disconnect wires to fan motor - place 6" fan to blow on condenser - fridge began cooling & freezing again - ordered part - part arrived - removed fan motor & bracket - cleaned brackets & fan blade - cleaned lint & dust from condenser compartment (took longer to clean than anything else) - replaced fan motor - replaced cover - was hero with wife ... :-)
Simple. UNPLUG THE FRIDGE. Remove set screw holding valve to frame, switch hoses one at a time into new valve, switch wires one set at a time from old to new, re-attach the new valve, turn on water , plug in fridge, check for leaks. 2-minute job.
I weged a block of wood under the door to hold the weight then used a nutdriver to removed the two screws attaching the bottom hinge to the refrigerator. The plastic closing cam was broken and preventing the door from closing. I found some plastic washers in my junk drawer to install on the lower hinge as a temporary fix to keep the appliance operational until the correct replacement parts could be tracked down. I then called local appliance stores in search of the closing cam and learned that none of them had the part in stock. I then hit the internet and within minutes found a picture of exactly what I needed at PartsSelect.com and had it on order a couple minutes later. A couple days after that, the new hinge was delivered, Again, I proped up the door, removed the lower hinge and replaced it with the new the new one that included the new closing cam. I was very happy to have saved lots of time and money and my wife was even happier to have the refrigerator working properly again. :)
Unplugged the refrigerator. I took all the food items out of the freezer, took out the ice bin and shelves. Then I unscrewed the back panel and removed it. The freezer coils were frozen over with ice. Then I used a large fan to thaw the ice and cleaned up the water with towels. I unscrewed the old defrost heater at the bottom of the coil section, removed it and screwed the new defrost heater part in. I ended up using some dikes to cut the wiring midway up . ( I was going to use the new plastic plug that came with the new part, but it wasn't correct ). I spliced the wires together ( the color scheme was the same - pink to pink, blue to blue, etc), capped them , taped them with electrical tape, and I covered them with a corner from a sandwich bag and taped them a bit more to keep moisture out. Then I tucked the wiring up away from the coil section. I also spliced this little cylindrical part into the existing wiring harness and clipped it onto the copper tubing. ( I suspect this is the defrost timer, but I'm not sure ). After I removed the the old cylindrical little part, I noticed the cap was popped out of it. (it looked like it was damaged a bit ). Once I got all wiring tucked away and back in place, I put the back panel back on, plugged it back in. Voila'. Easy as pie. It's been running fine ( about a week now) ever since. I replaced the thermostat sensor first since that was the cheapest part, but it wasn't the problem. So I moved on to the defrost heater and that ended up being the bad part. I repaired my refrigerator for less than $100.00. Thanks PartSelect. You rock!
Ice Maker was leaking all over freezer compartment
Pulled out the fridge, took off the cardboard back. Get a nut driver instead of screwdriver (easier). TURN OFF WATER NOW. UNPLUG FRIDGE NOW. Removed one screw holding valve. Pulled off electrical connectors. Use two small adjustable wrenches to remove water lines. Tag the plastic tubes (I marked RED and BLUE). Grab the new valve and try to stuff it into the same space. Whoops ! Dang plastic housing protecting the electrical from the water is in the way. Have to cut most of it out to make it fit. By the way, DONT follow the instructions about take the bracket off the OLD solenoid. You don't need it. Just throw it away. Connect the wires (remember to use the adapters sent with the new solenoid) Mount the new solenoid (now that the plastic is out of the way) with the one screw (nut driver). Hook up the supply water line (wrenches). Hook up the plastic tubes (aren't you glad you marked them ?). The tubes just push into the new solenoid, no more threads. I just left the plastic nuts on the tubing. TURN ON THE WATER. Check your connections for leaking. Do this before plugging in the fridge. If OK, plug in the fridge. Run some water on the door, look in about an hour to see if cubes are making now. Put cardboard back on fridge. Push fridge back against wall. CONGRATULATE YOURSELF ON A JOB WELL DONE.
Ice buildup. The Ice Machine was frosting over. Ice (due to frosting) would block the drop chute.
Unfortunately, the replacement part didn't come with instructions. The repair, nevertheless, was fairly straightforward. After removing the plastic parts that guide the ice through the door (by removing a few screws that attach the parts to the inside of the door), I was able to slip my hand into the ice maker dispenser and remove the old part. The part clips on. It is a tight fit through the funnel (from the outside of the freezer), however, and requires that the gasket first be "flipped" open wherein it unfolds 180 degrees. Doing this will make it easier to clip the new gasket onto the assembly.