Enter the code USA15 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on July 1 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
freezer cold and frosting up but refrigerator warm
inside the freezer compartment, remove four hex head screws from rear panel,lift panel forward and unplug wire assembly from panel. find old defrost thermostat attached to copper tube by clip on back of thermostat, unclip, snip two wires to thermostat, take new thermostat, strip 1/4"of wire from wires in freezer (thermostat is prestripped),insert light blue wire from thermostat and light blue wire from freezer into opposite ends of crimp connector and crimp securely. repeat with dark blue wires. set panel back in freezer,connect plug to back of panel, refasten screws and you are go to go! save yourself the price of a new refrigerator or $300 repair by repairman!
After unplugging the fridge, I took a small flat headed screwdriver and carefully pried off the light switch from the inside, right side of the refrigerator. I disconnected the 2 wires from the switch and replaced it with the new switch and pushed it back into the frame of the fridge. Done !! Very very easy !! Thank you
Freeze would not re-start after temp rose above 23 degrees.
Unplugged the freezer. Located the Run Capacitor (next to the compressor). Removed the wire holding bracket, removed the Run Capacitor from the Start Relay. Installed the NEW Capacitor, re-installed the holding bracket. Plugged the unit in, looking at the display for the proper start-up sequence data. All is good - freezer operating for another 10+ yrs. NOTE: When removing the Run Capacitor, beware the COMPRESSOR could be HOT to the touch.
Light Switch too loose so no longer triggered by the door.
Googled it on Youtube - unplugged the fridge, used a paint scraper to loosen the old light switch, unplugged it from the electrical source, connected the new switch, replaced the whole unit into the proper location and pushed it firmly into place.
Broken drawer support rail (left side), broken door shelf retainer bar
Followed instructions given on web site. My husband is not much of a handy-man, but he did these replacements in a matter of mere minutes. So happy to have the broken pieces replaced and all is working well again!
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker. 2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,. 3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket. 4.Now take out 8 screws that hold the back panel in place and remove the back panel. 5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.