wasn't making ice. The ice bin actually filled up with water.
Removed old valve first, found part # on it.
Entered part # into search box on computer.
It came up with the right replacement part the first time!!!
Ordered part, it came in sooner than I thought it would.
I attached the supply line, pushed in the plastic outlet hose, connected the power line, and attached it to the refrigerator frame. We had a full container of ice the next morning.It couldn't of had been easier.
Parts Used:
Single Outlet Water Valve Kit
  • Bob from Middlefield, CT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
shelf bracket broken and gone
I tried to pull out the wire that was sticking out of the side of the 'fridge with the pliers, however I could not get it to come out so I just pushed it in. I then put the new shelf bracket in the opening and set the shelf on it. It was easy.
Parts Used:
Shelf Stud/Support
  • Deborah from Phoenix, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker Quit Making Ice
Ice make was still working but no water coming in to make ice . Pulled refrigerator back and found water valve at bottom of refrig close to the floor. I disconnected water line and electric plug - went to whirlpool web site - no help at all to confusing - found partselect and compaired picture of old valve with picture of new valve . When I got it in mail it took 30 min to install - working fine now hint - mark top of electric plug so you install correctly
Parts Used:
Single Outlet Water Valve Kit
  • WILLIAM from Altamonte Springs, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench (Adjustable)
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer would periodically allow things to partially thaw out
First, I removed the two thermostat knobs, then the snap-on plastic cover. Then, I removed the 4 screws holding the housing for the timer, thermostats, etc., and dropped it down enough to remove the timer and the wiring harness going into it. Installing the new one was the same process, in reverse. Quite simple!
Parts Used:
Defrost Timer
  • Dana from Canyon Lake, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken kickplate
just snapped it on,
Parts Used:
Kickplate Grille
  • Patricia from Ypsilanti, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
8 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer was dripping water into refrigerator below
Removed the old timer from the housing. The replacement came with good instructions. I followed the instructions corresponding to the color wires in my unit. The first time it was installed, the fridge did not come on and the temperature rose after a couple hours. Looked at the part and realized the defrost cycle must have kicked in. Needed to slightly turn the gray slotted part to initiate the timer so it would stop the defrost and start the fridge. That did it! It must have advanced the timer so it could accumulate run time. Whole repair saved us $3000 in a new fridge.
Parts Used:
Defrost Timer
  • John from Redmond, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The door light socket was broken and hanging down
The refrigerator light in our Kenmore fridge has been flaky for a number of years. The slightest bump would knock it out of the hole it fits into leaving the bulb dangling. Usually since we were used to it, we could avoid bumping it so it was no real problem, but a recent visitor bumped it and it once again was hanging. I decided this time, to take a serious look at it and fix the problem for real. I had options, duct tape, hot glue gun, goop...or a new part! A quick search on the internet, and I found www.PartSelect.com I entered my model # , quickly found the correct part number. The part came 1 1/2 days after I ordered it. The repair was very simple, I unplugged the fridge, removed the wires from the spade connectors on the old light socket, and attached them to the new socket. I then pushed the socket into the hole, and with new spring clips, it snapped snuggly into place. The socket came with extra wire connectors which I didn't need, the socket fits multiple brands of appliances. It also came with a bulb protector, but that wasn't needed for my fridge either. I was very pleased with the speed and ease of the repair. No more dangling light bulbs!
Parts Used:
Light Socket Kit
  • David from Roanoke, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water Fill Cup Broke
The Ice maker unit had to be removed and the shaft had to also be removed, which required dis-assembling the motor drive. The thickness of the shaft and the bearing fill cup prevents it from simply pushing it in place. Other than that I have Ice.
Parts Used:
Water Fill Cup and Bearing
  • Sam from Las Vegas, NV
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator light would not stay on
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced.
reassembled the pieces.
Parts Used:
Refrigerator Door Switch
  • Dave from Manchester Center, VT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Socket set
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My U-line ice maker quit filling.
I used this part on a little, under-counter U-line ice maker that is the best little ice maker in the world. The single solenoid part from U-line cost more than twice as much as the generic GE one I ordered from you. It arrived in only 2 days and I was able to just remove the inlet and outlet line from the old solenoid and unscrew the bracket to remove it. I used the included bracket and one screw affix the new one to the ice maker, then just pushed on the inlet and outlet lines, tightened them on, plugged it back in and In about 20 minutes from start to finish, it was back in business, cranking out ice really quick as it was before. Could not imagine summertime in Texas without my U-line,,,Thank you!!!
Parts Used:
Single Outlet Water Valve Kit
  • Anne from Arlington, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
frig stopped running and everything ruined
The frig was already empty....removed the plastic control knobs and loosened the hex head screws to remove the cover . The wires were the same at each contact point, so, it took about 15 minuets to adjust the control knob to match the old one and reinstall the thermostat and place the cover...The other 15 minuets I spent finding my wife to show her the frig was back to work...Just a walk in the park...
Parts Used:
Cold Control Thermostat
  • allen from Dickson, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
7 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The icemaker in my freezer stopped producing ice
1. Removed the icemaker door
2. Removed the two screws from the underside of the icemaker unit
3. Removed the slide-on plastic cover that protects the power cable connector
4. Removed the icemaker unit
5. Removed the two screws from the control unit
6. Pulled the control unit from the icemaker unit
7. Installed the new control unit and reinstalled the icemaker assembly

A repairman wanted to charge me $250 to do what I did in about 20 minutes for about $120.
Parts Used:
Icemaker Control Assembly
  • Edward from Annapolis, MD
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
3 inches of frost in Fridge, 72 degrees in Fridgerator
First defrosted it to makes sure all Air flow was opened. Tested the Defroster heater with omh meter, it was OK. Found the location of the defrost timer on the online diagrams. Used nut driver to remove cover.
Replaced timer. The hardest part was decieding how to wire it up, tis was a universal kit and depending on how it was wired as to how often the defrost ran. The firt choice was every 8 hours. Since this was going to be opened often, I picked that one.
Plugged it with in 24 hrs freezer wall mesured -5 and the fridge was at 30, so had to warm it up a bit.
Now all complaints gone, Ice making has been doing better also.
Parts Used:
Defrost Timer
  • Gerald from Orangeburg, SC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
6 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken filler tube at threaded connection
After discovering that the water noise was coming from the rear of the refridgerator upon pulling it foward I discivered the connection line had broken. So i got a phillips screw driver and removed the the two mounting screws and saw it was one piece. I easliy found the part on PartSelect website and once I got I merely swaped them out and it works good as new!
Parts Used:
Ice Maker Water Fill Tube Kit
  • Matthew from Phoenix, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Filler tube broken and old tube frozen over
this is a snap! 2 screws an a nut to tighten and it works like a charm. the filler tube in my Kenmore refer had broken off in the back. ( really bad location to put this in the beginning) if you push the refer to close to the wall you can break it off easily. remove the water line by loosing the nut and remove the hose from the fill tube ( This assumes you have already turned of the water supply or you are standing in a large puddle)remove the 2 screws that hold the filler tube in place. pull out the old filler tube in and slightly upright motion. replace the new fill tube into the same hole and replace the screws. replace the hose and tighten the nut, turn the water back on and check for leaks your done !!
doesn't that feel great?
Parts Used:
Ice Maker Water Fill Tube Kit
  • Alan from Chino, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 1069702610
91 - 105 of 644