The Freezer defrosted and everything on the top and the bottom spoiled
i had used your web site before and i read several problems that your readers had. i went to the back of the unit, removed the bottom cover and right there the i found the run capacitor and i chaged it. since i had only ordered this part to save money i went back and ordered the Start Device which when i took it off it was completely burned. the replacement part came labeled with 2 different compressor #, so i picked the one that i had and unpluged each wire. the part may differ from the one that it's in the unit but it worked when i pluged everything back on. it also helps to take a picture of everything before removing the wires in case you have to leave it and come back later. i hope to use this refrigerator another 10 years. thank you all for your help.
Parts Used:
Capacitor
  • Jorge from Miami, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
9 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no power to the ice maker
The wiring harness was a straightfoward plug in replacement after depressing the securing tabs, and did provide power to the icemaker. However, the icemaker would continually cycle, with the mold heater on at all times. I suspect this is what caused the thermal fuse to blow in the first place. Rather than spend more time replacing individual components, I eneded up replacing the full ice maker assy. The new ice maker works properly.
Parts Used:
Ice Maker Wire Harness
  • Thomas from Indianapolis, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
10 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water dispensed, but no ice.
We have a side-by-side and the tutorial was different than what we have. Had trouble getting cover off, but finally repaired and WE HAVE ICE! Also took longer than expected.
Saved a lot!
Parts Used:
Icemaker Control Assembly
  • NANCY from VALLEY VIEW, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer will not freeze or cool the ice box
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not working correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
Parts Used:
Condenser Fan Motor Kit
  • David from Choctaw, OK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set
8 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Parts Used:
Refrigerator Door Switch
  • Antonio from San Antonio, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
7 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condenser Fan Motor seized up
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!

Service and shipping were fantastic! I would definitely use Partselect again!
Parts Used:
Condenser Fan Motor Kit
  • Peter from Herndon, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker Quit Making Ice
Removed the two screws that hold flaping door. Removed the single screw that covers the connecting wires. Disconnected the wiring plug. I wiggled out the ice maker. Took off the motor cover. Swapped out one motor for the other. Reinstalled the icemaker in the resverse order of removal. Note the wiring plug in the freeze is very from. It makine s the reconnection differcult.
Parts Used:
Icemaker Control Assembly
  • JOSEPH from LINDENHURST, NY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No tempersture control, it was either onand freezing or off and hot.
A simple job to remove the plastic cover held by two screws. Then one screw which held the old controller frame. Then remove two screws which held controller. Putting it back was just the reverse.
I did not have to adjust the new control position but with the wrench in the kit it would have been no trouble to do that either.
The instructions were just fine and anyone with a little mechanical knowledge could do it
Parts Used:
Cold Control Thermostat
  • loy from Pahrump, NV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
7 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
In the ice storm in bootheel of Mo the power spiked a few times before it went off. When power came back on, my frige wouldn't stay working. I would have to touch the thermostat to make it cycle back on. Found exact parts on line at partselect needed to repair the fridge. thanks guys!
First I unplugged the appliance, then I took the two screws out that hold the cover over the temp. control knobs,then I removed the cover from the fan and thermocouple probe end. Then I unplugged the two hot wires from the thermostat,and then the ground wire. Then removed the two screws holding the thermostat in place and removed old thermostat. Installed new thermostat following steps in reverse order.
Parts Used:
Cold Control Thermostat
  • George from Gideon, MO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker slowed down, then stopped producing
First pull out frig and unplug. Shut off water valve. I just had to remove two screws to disconnect unit from bottom rear corner of frig. Pull element out just a few inches and disconnect the plug that feeds it electric. Disconnect water hose and reattach to new unit. Reconnect electric plug and reinstall in back of frig, securing with two screws. I have an older appliance, so I had to jury rig a bit when reattaching new unit by drilling two new holes for mounting. Also, I had to buy a new water hose because the old part would not accept the standard female end of the hose to connect to. Home Depot has the standard icemaker hoses with two female ends. These two glitches would probably not apply to a newer appliance, but anyway, it's cranking out the ice just fine now! Sure I saved alot of money, even with the extra $10 investment for the hose.
Parts Used:
Single Outlet Water Valve Kit
  • Paul from Sharpsburg, GA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set, Wrench set
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Switch Broke...Absolutely Fell Apart.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Parts Used:
Refrigerator Door Switch
  • Duncan from Metairie, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator had shut down
Went on line ,ordered part on Friday afternoon ,Fedex was at my house Saturday Morning,,THIS SERVICE IS GREAT ,,THANK YOU VERY MUCH FOR BEING SO FAST
Parts Used:
Defrost Timer
  • Ronald from Martinsville, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
7 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water leaked when the paddel was pushed
Followed the video on parts page. I was worried I would brake the cover but learned from the video the right way to remove the front plate. I found the video very informing. Thank you for saving me a service call and the part cost was minimal compared to a new refrigerator .
Parts Used:
Water Tube Kit
  • Monica from EDMOND, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Had to bang on the Thermostat to get the compressor to kick in.
1.unplugged the refrigerator.and took off 2 knobs, and 2 screws to remove the cover from the back wall of the refrigerator.Next I unhooked 3 wires,and removed the mounting bracket by removing 1 screw. I had to use a file to slightly modify the bracket, since the thermostat was not the exact same model as the original,due to the age of the refrigerator.(40+years) I reassembled in the reverse order, and it works great
Parts Used:
Cold Control Thermostat
  • Richard from O FALLON, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator not cooling properly
Replaced refrigerator cooling control. No luck. Replaced freezer cooling control. No luck. Coils were icing up. Unplugged frig and allowed coils to defrost. After more poking around, found that condenser fan was not spinning. Touch it and it'd start. That was definitely in need of replacement. Replacement was easy. Refrigerator is now running as it should.
Parts Used:
Condenser Fan Motor Kit
  • Ernie from Windsor, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    1- 2 hours
6 of 9 people found this instruction helpful.