Enter the code USA15 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on July 1 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
broken fan with vacumme cleaner
I remembered to unplug first. took the little cover off on the bottom, unscrewed the 3 screws. then just held the base that the fan is on and pulled rite off, pushed the other one rite on. it took me five min, i want to say thanks to parts select, had the part, fast shipping, great job, thank you.
Lightning struct the house and fried the evap thermostat
Noticed the evap fan wasn't working, so trying to disconnect the wire broke the connection so had to order a new motor. Installed the motor but it still didn't work. Had a technician look at it and he said it was the control board. Ordered and installed control board and still didn't work. The only element left is the evap thermostat. Jumped the thermostat and it worked so ordered and installed a thermostat. It works now
it was very simple, my husband did it. had to take the top shelf out and screw in the support rail and that was it. couldn't have been any easier. this was the easiest process from start to finish that we ever had. looked up on line, found your website, ordered the part and it arrived in a couple of days. So easy and your company was most efficient in having the part and in processing. Couldn't have been mored pleased.
Followed video instructions which were to unplug refrigerator, on lower back use screwdriver, loosen 4 screws, take off plastic cover, pull out fan, replace with new fan, replace cover and 4 holding screws, plug in refrigerator. I am female, 77 years old and if I can do it, anyone can.
Evaporator fan motor quit and would not circulate cold air from coils.
Remove shelves and rear panels to get to motor. Motor is held in place on shroud by simple strap. Remove fan blade, then un hook strap, remove and save rubber spacers on old motor to reuse to remount new motor. New motor Mew motor has wiring harness that is universal. Cut out the three wires that go to the new motor leaving long as possible, cut wires from old motor as long as possible, strip ends of all wires 1/2 inch, connect wires by color,slip into provided wire connectors and crimp. Pull on wires to insure connection. Tie wires together so they don't touch the coils. Plug in and check operation. If all is working unplug and replace all covers and shelves. Plug back in and it will take few hours to reach operating temperature. Video of side by side repair shows easy removal of panels and motor.
The repair was a simple replacement. The problem was that after waiting three weeks for the new drawer to arrive I had to call the company and ask what the delay was?? They said the first order was lost in the mail?? Second order arrived within a week. But we didn't enjoy having to wait this long.
removed ice maker,,and screws holding back of freezer cover,unplugged wires and removed the cover and fan.wow,only wire to element had come unplugged!went ahead and replaced thermostat,and defrost timer,both were easy to do
I easily removed the shelf, cleaned it, removed one screw, adjusted a tab that was bent, then installed new side rail with the screw that was removed and put back the shelf and storage bin. Everything worked perfectly. I must have saved $100 by doing it myself.