freezer was freezing, refrig was not cold
Unplugged fridge, removed all screws from inside freezer panel. Removed bracket, fan blade and wires from evaporator motor and swapped motor with new one. Very easy. Professional repairman wanted almost $200 to fix it. Total cost for me was $35 and 25 minutes on a Saturday afternoon. Thanks PartSelect for the quick delivery, low price and tips on the replacement.
bottom of frezzer cold...top warm...refrigerator warm
I first located the wiring diagram under right frt. of fridge. Using it I troubleshot the problem to be the ADC module. I ordered the ADC module and blower motor that it controls(as a precaution since that is the device that the ADC drives)After removing the icemaker and all the back panels in the freezer you can access the blower motor. The ADC module is accessible after removing the plastic panels in the top of the fridge. Look for a burn spot on the module. Be sure to order the parts using the fridge model # and not the parts # on the wiring diagram(they will have changed since the model was built). Mine needed an updated wiring harness and deleted one of the dampner motors. Be sure to replace one wire at a time so not to get confused of wire location. Pretty straight forward repair if you have some mechanical ability. I have never repaired a fridge before, but have done car electronic work.
After unsuccessfully trying to change the blown light bulb I discovered that the plastic light socket had gotten so hot that it melted and permanently fused with the blown bulb. After my new socket arrived in the mail I just popped the temp control assembly out with a screw driver and removed the old socket and placed the new one in. Whole operation to 5 minutes.
The repair for this was very simple, although it was a tight squeeze. The model I replaced the ice maker on was a side by side. First I removed the ice bucket so I could have more room to work with. Then I unscrewed 2 screws on the left side wall holding the ice maker in place. These screws had a 1/4" nut top on them so I used my socket driver for this. Then a quick disconnect of the wiring harness. Very Simple. I did the reverse to install the new unit. Total time was around 5 minutes or so. I now have ice again.
The 2 year old used the 2 bottom trays as a step stool
Repair was pretty straight forward. The Plastic around the glass cover of the crisper pan all broke where the stud holds it up. Replaced both of the plastic covers.
The broken support stud was a bit of a pain, you have to use a long nose pliers to try and pull the middle stud that locks everything in place. Forcing the entire support stud out will crack the plastic body of the fridge, so you have to truly find a way to get that middle stud out first to lose the clamps. Look at the new one you have and figure out how it works to give you an idea of how you can pull out the broken one.
All in all, was a pretty simple install. More annoying as you have a small space to work in.
Pulled the fridge from encloser, removed rear cardboard cover and found compressor in rear. The compressor, being very accessable, was easy to find the bad starter/capacitor. I removed the spring retainer, pulled the capacitor off the starter, removed the starter by pulling outward and replaced with new. All went well when the unit started and cooled as new. Some noise at times, but traced to icemaker. As time went by, that noise was gone.
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires. Then I took the new icemaker out of the box and reversed the procedure.
Brand new refrigerator, but evaporator fan blade broken, causing considerable vibration and noise.
Really, really, really easy: 1.Unplug refrigerator (electrical safety). 2.Remove cardboard cover at bottom of refrigerator (two short self-tapping bolts) with a wrench. 3.Pull old fan blade off fan motor shaft (just held on by a compression fitting--no tools needed). 4.Push new fan blade on shaft. 5. Replace cardboard cover. 6. Plug in refrigerator, write nasty letter to Frigidaire.
Removed 4 screws holding face plate onto ice bucket. Removed the 3 screws holding the ice crusher housing. Noted postion and rotation of teh s;ring loaded ice selecting rod. Removed broken crusher housing. Reveresed process for installion. Took for test drive. Operational...
The old ice maker had stopped working properly. The cycle was inconsistent, and inlet water would run over existing cubes in the tray, before they were dumped into the dispenser box.
This was really simple, much like changing a light bulb. Two bolts loosened beneath the old unit to allow it to be lifted off and free. The power supply plug was easily disconnected. The new unit was then placed onto the loosened bolts, power supply reconnected and secured with the supplied wire tie. A small angled bracket was removed from the old and reattached to the new as a support toward the from of the unit. The cycle adjuster was backed off a 1/2 turn as per the instructions....and the next morning....new automatic ice. Life is good!
I followed a gentleman's directions on your website, very useful I might add. It helped me replace all the broken parts with ease. I am a 33 year old mom of two. Anyone could do these repairs that I did. Thank you.