Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Bottom drawer broken from too many beer cans.
Unloaded the drawer, pulled it out, took off the front panel, put the panel in the new drawer, reloaded the drawer, and put it back into the fridge. I had the new drawer back in the fridge before the wife even knew I had taken it out of the box. I have been banished from storing my beer in the bottom drawer sincs I broke the old one. This should be the last drawer repair that I have to make.
I pulled out the old pieces and poped what I couldn't into the foam insulation behind the support. Then I placed the new piece in the hole and popped the plastic pin to seat the support. bang. the only problem I had was knowing if it was the right part by the picture. The little pin that had to be pushed through kinda threw me.
upper storage drawer broke at the edges on the rail slide
Pulled the upper drawer out, slid the faceplate/handle up and out of the channel in the drawer. Took the new drawer and slid the faceplate/handle down into the channels and it was done.
Frequent dripping on floor and no cycling of compressor
After posting the specific symptoms and getting feedback, I had narrowed the cause to two linked parts. I ordered both intending to replace first one, then the other as needed. With parts in hand, I pulled off the freezer control knob, used a nut driver to remove the two panel securing screws (behind the face, against the inner ceiling) and gently dropped the cover down. The control (temp sensor and cold control) is easily accessible as it sits wedged into two slots in the plastic cover. The control must be slightly lifted in order to extract the long sensor that attaches to the control and runs under it and into a plastic sleeve behind the panel (the new control comes with the sensor wrapped in a tight coil and it must be unwound for the install). Removed the three wires noting which color goes where. Used needle-nose pliers to remove the small push-on tabs and removed the control. After starting the new sensor probe into the sleeve re-attached the 3 wires to the new control. Used the original as a model for how to pre-bend the probe for the first 2 inches as it was mildly frustrating to position the unit back correctly. Pushed everything back into place, re-installed the screws and plugged the fridge back in...(you DID unplug it first, right?). Still haven't used the second part (defrost timer), but I expect it to go soon...it is a 17 year old refrigerator, after all.
Wasn't sure if it was the derost timer or the heating element. Since the timer was much cheaper, I bought it and crossed my fingers. My story is like the others. Unplug the refrigerator, snip the old wires, strip back the wire insulation, use the supplied connectors to attach the new defrost timer to the existing wiring. Success! My coils no longer freeze up. Only difficulty is I am a large guy, and fitting my upper body into the freezer was challenging.
The defrost timer is located under the freezer side behind the lower plastic cover. Very simple, just 2 screws and a plug, and your done.
The thermostat requires removing the lower drawers in the freezer and unscrew the back side of the rails and let them hang over to get access to the lower cover on the back of the freezer. Once the panel is off you will be able to see the thermostat. From there you just remove the thermostat from the clip, cut the 2 wires, splice in the new thermostat and re install using the new clip and your done!!
This was my first time and it was really simple. I had a local repair shop quote me $375.00 . I did it myself for under 50.00 shipped to my door..
Freezer was getting a build up of frost on the condenser and wasn't cooling.
First I remove the back panel which had 4 screws. Then I removed the ice maker. The icemaker is held in place by the 2 screws that requires backing the screws out just a litter, than lift up and remove the electrical connector. Used a volt ohm meter to check the resisitant in the heater element and the defrost timing switch. Both tested good and that left only the thermostat. Removed and replaced the thermastat swich. I cut the ends of the old switch and crimp the ends of wire with the crimps that came with the swict i purchased from parts select. My refrigerator is working properly and making ice like normal.
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the wiring harness plug, replaced the old timer with the new one, re-connected the wiring harness and reinstalled the mount in position. Hardest thing about it was lying on the floor.
tested defrost timer and heater. And then tested defrost timer with ohm test($6 at hard ware store) Closed and would not open replace and tested freezer take 30mins to get switch cold and retest.
i removed rhe old storage drawer from the refrigator. removed the front face and slid it on to the new drawer i received from Part Select. put the drawer into the refrigator and it fit perfectly. Part Select web site worked perfectly on selecting the right part. the part was delivered in three days. i would recommend this company for your appliance replacement parts and would not hesitate ordering from them in the future.excellant service.