Enter the code USA15 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on July 1 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
No heat, would not light because igniter burnt out
Unplug dryer. Remove the front bottom panel of dryer 2 screws, then unplug wire connector to the old igniter then unscrew one screw holding ignitor then wiggle out. Open new igniter wiggle back in place insert screw tighten, (getting this screw back in is a little hard) replug wire connector to new igniter replace front panel with two screws. Plug in dryer and there you go drying clothes again. Wife all happy again.
Thermal fuse was blown so I replaced it. Still no heat. Hi-Limit thermostat and Cycling Thermo. had continuity as did flame sensor. Igniter tested 66ohms. I placed a wire jumper across the Hi-Limit and the igniter glowed, solenoids opened and gas came on. I orderd the Hi-Limit and since both "overheating" limiters were defective I decided to order the cycling thermo just in case. The Hi-Limit was received in 2 days but the Cycling Thermo was backordered. In the meantime my wife got antsy so I went ahead and installed the Hi-Limit and put her back in service... ...for one load. I wasn't certain if I had fried the "limiters" again but since they had continuity and I could measure continuity all the way to the Igniter I decided that it HAD to be the cause. I ignored the flame sensor since it never came into play without the igniter glowing... The igniter arrived and measured 56ohms. Hmmm... After installing the problem was solved. Word of advice: If the thermal fuse is blown and even if all else in the circuit SEEMS ok, go ahead and order the Fuse, Hi-Limit and Cycling Thermos, and the Igniter. It will take you about 30 minutes to install and you'll reduce your out-of-service time! Good luck!
First I pulled the dryer away from the wall and unplugged it. Next I removed the dryer vent hose and threw it away and replaced it with a more rigid metal vent hose. Next, I used a socket wrench to removed the screws holding on the back cover of the dryer. Once the back cover was off it was just a matter of using the socket wrench to removed the bolt holding the sensor in place. After the part was removed I made sure the replacement was orientated in the same way as the original part and then I unplugged the wires from the bad sensor and placed them in the same order on the new part and then I bolted the new sensor back in place. Since the new part has been installed the dryer is working flawlessly and is not turning off mid-cycle like it was. ***Oh, and an important reminder. When you have the back cover pulled off the dryer use a shop vacuum to suck out any dirt and lint in the back of the dryer and make sure you unbolt the metal chute that the dryer lint screen goes into and clean inside the area near the exhaust blower. This is a VERY IMPORTANT part of servicing your dryer and should be done every few months to help avoid the risk of a fire.****
Needed to repair and replace dryer motor pulley and pully
this was very was very easy. But I deviated from the You Tube instructions. One to release the motor pulley. I needed to use 2 adjustable wrenches for a longer lever. I needed to use a hammer to help release pulley. Second to remove the dryer cable I needed to use a small screw driver to aid in the release. ---- the part from the company was a perfect fit.
Dryer would not heat up properly. It would heat initially but once the heat was off it would not come on again.
I followed the advice posted by other customers. I took the front off the dryer, put the door back in place and ran a cycle. I could see that the igniter was heating properly, but no gas was flowing. Based on what I read I concluded that it was a problem with one of the gas valve coils. It was relatively inexpensive to replace both (and the dry is 10 years old), so I didn't go to the trouble of determining the bad one. I replaced them both. Obviously I unplugged the dryer (no need to turn off gas). There were 2 screws that held the bracket in place which holds the coils. I disconnected the coils, removed the bracket screws, replaced the coils, reattached the bracket screws and reconnected the coils. I then reattached the front plate to the dryer. It was very easy and took about 20 minutes and I had never worked on a dryer before.
First and Foremost i was told that my problem was with the Thermal Fuse (Fix Ya.com), Then with the little Electrical knowledge I have thought Fuses don't turn on and off,If the fuse was bad i would get No Heat. (Even for a second) Fuses just don't turn on and turn off intermittently,when they go there done! So after a little research i decided to order the gas coil valve. I tilted the top up, two screws on the front panel, took that off and the valves were exposed,(bottom left) two screws too remove bracket then installed new coils on bracket,put back together and I Have Heat Again! NO problems what so ever since new install. I would say having not been for cleaning lint build up inside the machine (been 6 years) the Whole project took me Ten Minutes.
Removed two screws from lint trap and pried front of top up gently. Top hinges backwards which is convienent. Two more screws take the front off. Removed drum and old parts. Removed rollers etc. Per the instructions. Cleaned inside of unit with a shop vac.
Reassemble unit and test. Nice and quiet again and working well. Great service fro. Partselect.com.
Gas dryer would not heat - pilot lit briefly then went off
Same as others. 1. Unplug dryer from power source 2. Use nut driver to remove two front screws at bottom of dryer 3. Disconnect cable connected to Secondary Coil (this is the coil towards the rear of the dryer) 4. Use angled phillips screw driver to loosen screws holding cap on top of the two coils. (Angled tool not required but seemed easiest to me) 5. Slide top cap back towards lock screw to allow coil to be lifted out 6. Remove and replace secondary coil 7. Replace cap, tighten screws to lock in place, reconnect cable to coil 8. Restore power to dryer, test and confirm gas flame stays lit 9. Replace lower front panel on unit
PartsSelect a great resource to use for home repairs like these. My first time using site and doing this type of work, now PartsSelect my first source to go to on such items.
I replaced both the thermal fuse and the thermistor at the same time. That seemed to fix the problem; but after a couple of days the dryer would not start. When pushing the Hold to Start button, the dryer just gave one beep and would not start. I did a resistance test on the old thermal fuse, and it was OK; so I put the old thermal fuse back in and the dryer works. Evidently, it was just the thermistor (thermostat, internal bias) that was broken. Both are very easy to change.
Dryer had no heat at all. This is an older gas dryer.
Cleaned out years of fuzz behind lower access panel and noticed where the igniter sits there is a metal tube about 1 inch in diameter. It had rust on the end and was starting to flake away. Found some helpful hints about how to test the igniter. Very easy, just used an ohmeter. Unplugged the 2 pin wire connector and checked for continuity. 1 lead on 1 pin and the other on the other pin., igniter side not the harness side from the dryer. A good igniter should read less than 5 ohms. I don't know the spec. exacttly, but it should not read open or infinite resistance. My meter read an open circuit. Removed the tube and igniter assembly, mine only 2 small bolts. I found the igniter element cracked. Ordered and installed igniter and tube assembly. This was a very easy install. 20 year old dryer works great and it's better than spending $500.00+ on a new one.
Gas would not turn on after around 10 minutes of "normal" operation.
I've nothing to add to the techniques already described in the other narratives except that the dryer operated normally at first, but then after around 10 minutes the flame no longer cycled. I suspected a bad high limit thermostat since the valves seemed to be working. I ordered the replacement coils only because they were listed as the most common thing to fail. After replacing the T-Stat there was no change; I started checking things w/ a multimeter and found that all the T-Stats were closed. I should have done that at first. Anyway, since I had the new coils I decided to put them in. The dryer has workd perfectly ever since. Lesson to be learned: the coils may check ok when cold, but become inoperable after heating up a bit.
I did what any novice would have done. I took the entire thing apart to get to the gas jet. I did not know about the thermal fuse until I got to the schematic behind the timer and controls. I was a tech back in the 70's and 80's and only worked on electric dryers. Back then I would remove the heater core and twist the coils together to save money. So I had no idea how a gas dryer heating unit worked. So now any one that reads this. You do not have to take the dryer completely apart, I did that for all of you. Just replace the thermal fuse on the back of the unit by unplugging that wires and removing the screws! It looks like a long white piece of plastic with 2 wires to it. You will find this under the full metal shield on the back of the unit. This should be about a 1 hour repair at the most!