The refrigerator was leaking water from the freezer section.
First remove all food from the freezer section, disconnect the power to the refrigerator and then remove all the shelves in the freezer.

Then remove the back panel inside the freezer by taking out the screws holding it in and then simply lifting it out. A Philips screwdriver and 1/4" driver was needed.

After the panel is removed, you can see the defrost heater screwed to the refrigerator coils. It's in two sections wired together. One section is screwed to the bottom of the coil and the top section is screwed half way up the coils.

Unplug the wires and thermostat (coming from the defrost heater) from the wire assembly located above the coils.

Next, remove the screws holding the old defrost heater (there are two screws for each element of the defroster)and lift the heater out. Pay close attention as to how the old heater is situated in the freezer in order to put the new one in the same way.

Attach the new heater by putting the bottom element on first and replacing the two screws to secure it. Be careful to keep the wires from tangling and attach the top element the same way.

Next, carefully connect the wires and thermostat from the heater back to the wire assembly the same way they were connected from the old defrost heater.

Place the panel back in place in the back of the freezer section, replace the shelves, and connect the power. You're finished!!

P.S. Don't forget to put the food back in the freezer.
Parts Used:
Defrost Heater with Thermostat
  • Joe from Summerton, SC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
14 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Existing light switch was hard to remove.
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
Parts Used:
Light Switch
  • Stephen from Jupiter, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
14 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
icemaker developed a leak and froze over
My husband did the repair, and even though our refrigerator is roughly 20+ years old, he was able to adapt it to work in all the right spots and we now have ice cubes! I'm very happy we did not have to spend $2000 on a comparable refrigerator.
Parts Used:
Ice Maker
  • debbie from chino hills, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
18 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
de light flasing on freezer door electronic disply
I removed the back wall panel inside the freezer compartment(approx. 6 screws). The coils were very iced up. I manually defrosted the the coils with a hand hair dryer. I then removed the 2 screws from each heater element and the clip-on thermostat from the coil. I pulled the elements, thermostat and wiring harness(item 230 on parts diagram) out of the freezer compartment and installed the new assembly. Electronic self-check of the defroster indicated normal. Further checks indicated the lower heating element was open.
Parts Used:
Defrost Heater with Thermostat
  • Sherri from Atlanta, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
12 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker ot making ice
First I replaced the double valve because the ice maker was not filling with water. It still did not work. Then I replaced the ice maker itself. This worked and was relatively easy to replace. I had to use the water fill "slide" from the old ice maker. The new one was too narrow and it leaked water into the freezer.
Parts Used:
Ice Maker
  • Barry from Phoenix, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
18 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice would not dispense
I removed 6 screws, unplugged assembly that had motor attached,removed from fridg,replaced motor and reinstalled assembly, putting back 6 screws.works like new.
thanks.
Parts Used:
Dispenser Crusher Motor
  • john from montgomery, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
14 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
This replacement of the light shield was fast and easy. I wish they all good go this smooth.
I repaired as follows. 1) Open freezer door. 2)Removed ice maker bin. 3) removed screw with broken tab on it. 4) install new shield slide to side.
5) Reinstall screw. 6) Grab TAB (tasty adult beverage) and enjoy on back deck while talking about how good you are at repairing stuff.... HA!
Parts Used:
Freezer Light Shield
  • Stephen from Northglenn, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
11 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker Timing was off
The Ice maker would not run through a cycle. It would fill with water and produce ice but would need a little help by pressing up on the ejector to run through its cycle. Otherwise, it would not bring the ice to the holding bend. Sometimes the water would not fill. The icemaker was making ice it just was not letting the ice maker run through its cycle so I figured it had to be the circuit board. I bought the circut board which was easy to install.
1) Turn off water line and unplug power.
2) Pop off front panel plate at ice cube select switch area.
3) Unscrew 4 screws that holds control panel housing in place.
4) Remove panel assembly by disconnecting two different wiring plugs.
5) Unscrew 2 screws that allows access to control circuit board at end cap.
6) Remove circuit board by sliding it out of the assembly housing.
7) Install new circuit control board in assemble housing and screw on end cap retainer.
8) Attach two electrical wiring plugs.
9) Install control board assemble housing into frig opening and secure with 4 screws.
10) Install front panel plate (pops on).
11) Plug in power and turn on water line.
Parts Used:
Dispenser Control Board - 2 Slide Switches
  • Mark from Antelope, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
11 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light switch broken/door handle worn
To repair the light switch you need to replace the control board since the switch is not replaceable. The control board is easily gotten to by removing the outer cover, which snaps out, the removing the screws that hold the housing for the control board, make sure you disconnect the power and turn off the water supply before you remove the outer cover.. The board is held in place by a bracket which has two screws, make sure you disconnect the two wiring harnesses before the bracket. Once you get the bracket off the control board slides right out. To install the new board, just reverse the process.

Changing the handle is accomplished by remove popping out the top and bottom trim pieces, then remove the upper and lower screws from the handle. Reverse the process to install the handles.
Parts Used:
Dispenser Control Board - 2 Slide Switches Door Handle Kit
  • Gene from Anaheim Hills, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
This part on refrigerator went out, wouldn't dispense water.
I removed the back cover on the refrigerator. Unbolted the unit. First of all I unpluged the refrigerator. Took off the two electrical connections and removed the input and output water lines. I then reversed this process when I installed the new part. It was real easy.
Parts Used:
Dual Inlet Water Valve
  • Glen from Harrisburg, OR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
13 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replace Dual Inlet Water Valve
Unplug the electrical power to the refridgerator, remove old valve, marking which electrical wire set goes to which solenoid valve. Cut the nut fasteners from the ice maker and front door water tubes. Leave the nut fastener on the supply line.

New valve - remove plastic shipping protection guard, remove rubber cap from supply connection, bend mounting bracket to a 90 degree bend, attach electrical wire reducers to the small wattage solenoid wires then to the solenoid, attach large wattage solenoid wires to the large solenoid, push ice maker tube into the small quick-connection(no nut fastener needed), push the front door water into the large quick-connection, finally mount valve asembly using same holes in frame as held the old valve assembly. Plug in the power. Solenoid valves may take an hour or so to operate.
Parts Used:
Dual Inlet Water Valve
  • Timothy from West Windsor, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers, Wrench set
16 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Flapper was stuck open. Old and warped.
Replaced flapper
Parts Used:
Dispenser Door Assembly or Flapper
  • James from Virginia Beach, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
16 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Moving the refrigerator into my new (very old) house we had to remove the doors which resulted in a crimped hose and union
Remove lower front panel, disconnect damaged union from water hose under freezer door, replace with new union, tighten and reattach front panel. No more water coming from under the unit. Ice maker and dispenser features returned to working order!
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch
  • Laura from Manchester, NH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
16 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Frost was accumulating in freezer section.
Loosened screws holding old gasket to door. Removed old gasket. Fit new gasket around strips holding gasket in place---this was not easy. Tightened screws.

New gasket corrected problem.
Parts Used:
Freezer Door Gasket
  • Jack from Copperopolis, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
12 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator warm / Freezer iced over
I began by turning off the refridgerator and then removing all of the drawers/bins and icemaker from the freezer.

I removed the three phillips-head screws across the top of the rear access panel. (same height as the light bulb) I then removed the two phillips-head screws from the bottom of the access panel.

I removed the access panel by swinging the left side forward to clear the drawer slides, while keeping the right side back against itsattaching points. (Like a door swinging on its hinges.)

I followed the wire harness from the upper heating element up to its connector and unplugged the defrosting heaters from the plug. I then gently removed the little (just smaller than a tea light candle) thermostat from the top of the coils. (Not far from where the wire connector was.)

I removed two phillips head screws for each heater unit and removed the whole thing as on big assembly.

I installed the new parts from the bottom up, careful not to damage anything. I installed the new thermostat carefully and then reconnected the wire harness. Next I reinstalled the access panel, starting twith the top center screw to hold it in place during the installation of the other 4 screws in the corners.

Lastly, I put the drawers / bins and icemaker back in and turned the refrigerator back on. DONE.

It corrected the problem. THANKS for the Great Customer Service, too!
Parts Used:
Defrost Heater with Thermostat
  • David from Lynnwood, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
10 of 10 people found this instruction helpful.