Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Existing light switch was hard to remove.
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
First I replaced the double valve because the ice maker was not filling with water. It still did not work. Then I replaced the ice maker itself. This worked and was relatively easy to replace. I had to use the water fill "slide" from the old ice maker. The new one was too narrow and it leaked water into the freezer.
Get 2 "door closing cams" yep. Same as some others here. Found some black plastic pieces on the floor, when door wasn't closing right. I took the door off by taking off the top bracket. Very easy. Bottom bracket has the broken cam riveted to it. Need hacksaw to get this off then punch it through with hammer and a screwdriver. This is the only part that took a little while. Replace the closing cam and find a small nut & bolt or screw to replace the rivet you just sawed in half. Replace the closing cam that is on the bottom the the door as well. Even if yours isn't broken. Replace it anyway. Put door back on and done. Not a diffucult project if you know about the rivet and needing 2 closing cams beforehand. Good luck
Turned off power, removed cover from Ice maker, checked resistance across thermostat for zero (read open), all other switches read proper value (when activated). Ordered and received thermostat. Removed Ice Maker from freezer, removed two screws holding ice tray to Control Assembly. Removed Thermostat and replaced with new one. Applied Silicone Sealant to face of Thermostat for adhesion to ice tray when assembled. Remounted Ice Tray to Control Assembly and remounted in freezer. Works Great...
Moving the refrigerator into my new (very old) house we had to remove the doors which resulted in a crimped hose and union
Remove lower front panel, disconnect damaged union from water hose under freezer door, replace with new union, tighten and reattach front panel. No more water coming from under the unit. Ice maker and dispenser features returned to working order!
The auger was chromed steel. It rusted causing rust to get on ice.
It's a good idea to take closeup pictures, that will eliminate guessing when you put it back together. There was no instructions. I was happy to see GE knew there was a problem with the chrome auger. The replacement is STAINLESS STEEL.
It took me about 15 minutes to complete the repair, 1st I emptied the ice maker, then I removed 4 screws from the rear of the ice maker tray and took the plastic piece off of the auger. I reversed the steps and put it back together.
First I turned the refrigerator and water line off. Then moved to the freezer section, followed the directions, removed the two screws. Directions state to not remove them but I had to in this case. Unplugged the ice maker and removed it from the freezer. I installed the two mounting screws then tried to plug the electrical connection back in but had to use the adaptor cord furnished in the kit. The cord was a little long but I tucked it in and mounted the ice maker. Turned it on then turned the refrigerator and water back on and in a few hours had ice! Very easy to do!
Moving the frig out and cleaning was the hardest part of this job - lots of dust collected over the 17 years the frig was in place. Once all the cleaning was done, with the frig out and back cover off (10 -12 screws taken off with nutdriver),I plugged the frig in and observed the the problem was a noisy fan motor. The motor is at the very back of the frig with easy access to the 3 brackets holding it in place. Pull off the electrical clip. Remove the screw holding the bracket to the frame on the front bracket, leaving the bracket attacked to the fan. The other two screws remove from the fan, leaving the brackets in place. Reverse the procedure when you receive the new part from PartSelect(great company to deal with)!
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapped the new switch into place.
First turn off the power, remove the ice tray, remove the two screws holding the ice maker to the side of the freezer, use the screw driver to gently open the electrical clip for the power cord inside the freezer, remove the complete unit from freezer, bend the old stripper from the holding pin- it is flexible- it will bend, replace the new stripper on the holding pin and bend into the slot to hold it firmly, no water will come out from the fill cup into the freezer, plug in the power cord, mount back to side of freezer, you are done.
I weged a block of wood under the door to hold the weight then used a nutdriver to removed the two screws attaching the bottom hinge to the refrigerator. The plastic closing cam was broken and preventing the door from closing. I found some plastic washers in my junk drawer to install on the lower hinge as a temporary fix to keep the appliance operational until the correct replacement parts could be tracked down. I then called local appliance stores in search of the closing cam and learned that none of them had the part in stock. I then hit the internet and within minutes found a picture of exactly what I needed at PartsSelect.com and had it on order a couple minutes later. A couple days after that, the new hinge was delivered, Again, I proped up the door, removed the lower hinge and replaced it with the new the new one that included the new closing cam. I was very happy to have saved lots of time and money and my wife was even happier to have the refrigerator working properly again. :)