Models > TFF24RA > Instructions

TFF24RA General Electric Refrigerator - Instructions

All Instructions for the TFF24RA
16 - 30 of 160
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Switchlight was broken on tennant's refridge
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapped the new switch into place.

10 minutes total.
Parts Used:
Light Switch
  • Mark from Somers Point, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator door wouldn't close
I weged a block of wood under the door to hold the weight then used a nutdriver to removed the two screws attaching the bottom hinge to the refrigerator. The plastic closing cam was broken and preventing the door from closing. I found some plastic washers in my junk drawer to install on the lower hinge as a temporary fix to keep the appliance operational until the correct replacement parts could be tracked down. I then called local appliance stores in search of the closing cam and learned that none of them had the part in stock. I then hit the internet and within minutes found a picture of exactly what I needed at PartsSelect.com and had it on order a couple minutes later. A couple days after that, the new hinge was delivered, Again, I proped up the door, removed the lower hinge and replaced it with the new the new one that included the new closing cam. I was very happy to have saved lots of time and money and my wife was even happier to have the refrigerator working properly again. :)
Parts Used:
Door Closing Cam
  • Allen from Paso Robles, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator did not cool
i put a new evaporator motor in and now it works fine
Parts Used:
EVAPORATOR FAN MOTOR KIT
  • Carl from Kent City, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
10 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refridgerator was running constantly and condesor would get very hot, condesor fan would only turn on if I spun it.
Unplugged fridge removed the three screws that held fan on to fan frame unplugged condensor fan removed brackets from old fan and put them on new fan installed new fan plugged in fridge and now it works great!
Parts Used:
Condenser Fan Motor
  • Raymond from Los Lunas, NM
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Socket set
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door Would Not Close Properoy
Door cam disintegrated after 20 years. This was a terrific site for suggested repairs. My problem was not paying attention to how the door shim, cam and spacer were placed on the hinge. Most of the site's instructions did not forewarn the obvious...pay attention when doing repairs!!

Instructions from others were generally pretty good but as adept as I am at D-I-Y I still did not pay attention to how I took something apart so it could be assembled properly.

I don't think that ordering an entire door hinge set is necessary. It does not appear that shims and/or spacer come with the hinge assembly. Door cam was all that was needed. I thought about replacing the cam on the freezer side but won't do it until absolutely necessary.

This is a very good website and my thanks to all of the posts for the instructions!!
Parts Used:
Door Closing Cam
  • Mike from Lake Sherwood, MO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisy freezer evaporator fan, bearings worn out
UNPLUG UNIT. Open freezer compartment, top door. You may want to let it warm up a bit before beginning work. Next remove single screw from small square plastic grate at top left back of freezer compartment with phillips screw driver. Remove green ground wire connection behind removed grate with nut driver. Next remove 2 screws at top of freezer compartment holding plastic air diffuser bracket in place and holding back panel. Remove metal back panel of freezer by pulling top towards you, then angle out of compartment. Evap. fan is now exposed. I inspected and removed fan by removing two screws with nutdriver on bracket behind fan blade. I inserted nutdriver (with long socket driver)between fan blades to screws on bracket behind blade - 1 each side. After these two screws are removed, pull fan and bracket assembly out from plenum. Remove wiring from motor and remove motor to workbench. Remove round metal clamp from fan hub with needle nose pliers and slide off fan blade from motor. Also remove bracket and rubber bushing. Disgard old motor. Inspect and clean blade. Replace if necessary. Reattach rubber bushing, bracket THEN fan blade to new motor. New fan has atleast one terminal in new location and I had to use one wire extension that came with kit. Route wire behind motor and plug in new wires to back of motor. Insert fan and bracket to plenum, hold in place with one hand while reattaching screws with nutdriver between fan blades. Once fan is in place and nuts secure, I tested operation by plugging unit back in to make sure new motor ran and fan spun freely. Reattach back panel, top diffuser bracket and small grate with 3 screws. Shut door, set temp. and wait 24 hours before loading freezer. Unit good as new!
Parts Used:
EVAPORATOR FAN MOTOR KIT
  • Todd from Saint Paul, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door Closing Cam Disintegrated
The door closing cam on the refrigerator door was a snap to replace. However, I'm still baffled on how to replace the freezer door side. The condensation tube from the door runs through the door pivot and joins to a compression fitting behind the bottom trim piece. The compression ring is behind a formed lip on the tube and won't slide off. I could cut the tube but I really didn't want to do that. If anyone has done this and knows the trick to replace it, I would appreciate it.

Ed. Please post your question at our repair forums, forums.partselect.com.
Parts Used:
Door Closing Cam
  • Charles from Hubbardston, MA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Socket set, Wrench (Adjustable)
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door would not close properly
I stacked three 2x4's that were approximately as wide as the door in length. This required lifting the door about 1/4" but it also got the weight of the door off the cam so the bracket assembly that the cam was attached to could be removed. I drilled out the rivet that held the old cam in place and like previous DIY's had to use a small bolt and nut to secure the new cam in place. Reattached the bracket with the new cam and that was it. The only problem was that the head of the bolt I used was not flat enough to allow proper clearance for the door to swing freely without feeling some drag and the wife noticed that immediately. I told her to wait until the weekend and I would again remove the door and file down the head of the bolt to allow the required clearance. After a few days of use, the door itself ground enough material off the head of the bolt so that the door began to open and close properly. So now she's happy, I'm happy and the dog is happy.
Parts Used:
Door Closing Cam
  • Dan from New Braunfels, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
stopped making ice
First I turned off the water supply. Then I removed the ice bin and the ice maker by removing 4 screws and 3 electrical connections. This allowed access to the evaporator fan which was not moving. To remove the evap fan I removed two screws that hold the fan bracket. The fan assembly now had to be pushed back and rotated to remove from hole. There are 3 electrical connections that have to be disconnected from the fan, one ground wire that also is connected to the fan bracket and 2 power connections. Installing the new fan was the reverse of the above except the power connections were in a different location and i had to use the extension wires provided with the new fan to have the length needed to make the connection.
Parts Used:
EVAPORATOR FAN MOTOR KIT
  • Timothy from Orange Park, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door wouldn't stay closed & was out of alignment
This repair replaced two riser cams - one attached to the bottom fridge hinge and one attached to the bottom of the door. The two cams
mate together. So, don't just buy one cam, buy two.
1. Removed all contents off the inside of the door as well as the bins.
2. Unscrewed single screw holding plastic cover over top hinge.
3. Unscrewed 2 screws holding top hinge to the top of the door and removed the top hinge.
4. Pulled door up and off bottom hinge and layed
on floor.
5. Removed plastic grill on bottom of fridge.
6. Removed 2 screws holding bottom hinge in place.
7. Using a vice to hold the hinge, I used a hacksw to cut through the rivet holding the riser cam to the hinge plate.
8. Used a small bolt & nut to secure the new riser cam to the hinge plate.
9. Reattached hinge plate to the bottom of the fridge.
10. On bottom of the door remove two screws holding riser cam to door.
11. Position new riser cam in place and reattach to bottom of door.
NOTE: on my door, the metal SHIM that goes between the cam riser & door was also broken. I ordered the replacement SHIM but it turned out to be made of PAPER. So, I didn't bother putting it on. If the riser cam wears out again, I'll just replace it again.
12. Put door back on and secure the top hinge to the top of the fridge and you're done.
Parts Used:
Door Closing Cam
  • Rod from Nashville, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set, Wrench set
8 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Started to see a little sweat in freezer and ice cream not getting hard frig staying on longer.
Pulled frig out. Removed back cover. Unplugged frig, unplugged motor. Removed fan from old motor first then 3 screws from bracket that holds motor and removed motor. Reattached motor back on bracket, reattached fan on motor. Plugged fan back in and then frig. Everything worked fine no more soupy ice cream !!
Parts Used:
Condenser Fan Motor
  • Frank from Philadelphia, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set, Wrench set
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Not cooling - cond fan did not turn
Unplug refrig! Removed back cardboard covering (~5 screws)
(1) Cleaned all the dust out (hardest part!)
(2) Removed power wire to motor
(3) Removed 3 bolts holding motor to frame
(4) Removed motor/fan blade to the left
(5) Moveded fan blade to new motor (clean it!)
(6) Replaced motor, reinstalled 3 bolts
(7) Plugged power wire to new motor
(8) Tested it - worked fine, failed safe, drained to bilge!
Replaced back cover (had to tape it since I horked it up removing it)
Parts Used:
Condenser Fan Motor
  • Daniel from Great Falls, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Socket set
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Unit would not terminate defrost cycle resulting in melted frozen food
Turn of power to fridge. Removed all shelving in freezer section. Unscrewed back panel from freezer area. Removed old defrost term t-stat from top of evaporator coil assembly. Cut existing two wire leads, spliced in new T stat wires. sealed wire splices from water egress and clipped new t-stat in same position as old one. Reassembled rear panel, installed shelves. Turned power back on.That's it.
Parts Used:
Defrost Thermostat Kit
  • Gary from CONCORD, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fresh Food section door made a click noise on closing
Since the cam riser was obviously broken I obtained a replacement.
It also broke. The door hinge cam needed to be replaced also.
To repair Remove the hinge cover using a #2 phillips driver. Than remove the Hinge using an 8mm socket. Turn the door upside down and, using an 8mm socket remoge the cam riser and the door hinge cam.
Replace in reverse order.
Be sure to inspect all parts and order all required.
Parts Used:
Door Closing Cam
  • Charles from Renton, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
unusually noisy
Removed the three screws from old motor body-bracket assembly , pulled off 1/4'' spade terminals and removed shield from terminal block for re-use.
Removed fan from old unit and installed on new,
screwed new motor in place, replaced terminal wires, plugged back in refrigerator.
Now my old rerfrigerator is whisper quiet
Parts Used:
Condenser Fan Motor
  • Anthony from South Plainfield, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the TFF24RA