Magnitron failed
Over the stove microwave installed in top cabinet row. 1. Unplug device. 2. Two people to remove from wall/cabinet (remove two, large, top mounting screws and rotate entire microwave down and off the wall mount). Should be some wood spacers between top of device and bottom of cabinet. 3. Remove screws from sheet metal cover. 4. Remove one screw holding blowers in place and rotate out of the way, in order to gain access to 2 of 5 screws that hold the magnetron in place. 5. Unplug magnetron and remove the 5 screws. 6. Drop in new magnetron and re-assemble microwave in reverse order (steps 5-3). 7. Two people restore micro to wall/cabinet. Replace wood spacers, re-install two, large mounting screws (finger-tight). Test device. Secure the two large screws.
The bottom latch of the latch/spring assembly had broken off
First I removed the inside of the door using a putty knife and loosening the edges. I removed the old latch by- (1) lifting up and sliding both the top and the bottom out of the door (2) pulling out the bottom part and (3) using a small plastic fork to push the spring off of the top part (paying close attention to how it was already sitting in the microwave). It required a little twisting (not much) and it came out.
I put the new spring on the new piece on the hook part. Then I put the new spring on the oven (where the old spring had been). I stretched the latch up and put the top slot back in and then with a little (very little) pressure I popped the bottom back in.
First remove all screws holding on outer metal casing of microwave. Next remove the back and bottom metal pieces. You will then be able to pull aside the outer casing so you can access the door switches. Check each switch with an ohm meter in both the open position and with the switch closed. If the ohm meter reads the same in both the open and closed position, the switch is bad. Check the top switch first. Replace switch and reassemble. Cheap fix for a costly microwave. Great customer service at Parts Select!
I needed to acquire and install a mounting plate for an over the range microwave
I attached the mounting plate to the wall as directed in the installation instructions which I had downloaded from GE. This procedure took 45 minutes to complete. I was then able to mount the microwave.
Disassembled the front cover, found slow blow fuses, then replaced with microwave fuses 250V-20Amp. Utilized a few fuses to pin point the problem, Microwave functions all worked except the express feature, made an assumption after using a tester that it was the high voltage capacitor and the diode that attaches. Replaced both, plugged in and tested. Worked! reinstalled the unit. Sucessfull for the past month.
This was easier than I had expected. Many of the instructions involved removing the door. I decided to skip this when I found a Youtube video showing that the latch replacement required little disassembly. Here are my steps #1 Open door completely and, if needed, have someone steady it. #2 Using a thin plastic putty knife, gently pry off the plastic fascia from the inside of the door. Try to break as few of the plastic retaining tabs as possible (my total was about 10). #3 Slide the old latch upward and outward towards the outside edge of the door with your putty knife. #4 Remove the old latch and spring. #5 Attach the new spring to the latch and hook it to the retainer on the door. #6 Lift the new latch into place, it will drop into the slots with no or little persuasion. #7 reinstall fascia. #8 "nuke" last night's pizza ;)
Opened door to get food put more food in closed door it wouldnt work
Everything worked on the display light inside worked but when you closed the door and set time it would start counting down but not heating nor would the turntable turn. Started reading troubleshooting chart and first thing I did was removed the cover and checked door switches and found primary door switch wasn't working so I ordered a new one installed it and it worked. Anyone doing this has to be very careful because of the stored energy in the capacitor is strong enough to kill. My micro is only 2 years old so I was hoping it wasn't anything major.
Would not heat and made a buzzing or popping sound
Unplug the microwave. Remove the Philips head and safety Torx head screws along the bottom of the sides and rear of the microwave which hold the black cover on. Lift the cover up at the rear and slide it backwards to disengage the tabs on the front top. Remove the cover. Discharge the capacitor by shorting the terminals to each other and then ground. Do this with a well insulated object and be aware there may be a pop when you do this. Keep hands, etc. on the insulated part of the object (screwdriver handle, etc). There's a lot of stored energy in that capacitor. I'd advise first checking the diode to make sure its not bad. Replace it if it is. The Magnatron is held in with a couple of screws on the top and sides. Unplug the connector and remove the screws. Remove the Magnatron. Installation is the reverse of removal.
I REMOVED THE TOP PANEL OF THE MICR0WAVE AND THEN REMOVED ONE SCREW TO REMOVE THE CONTROL PANEL. rEMOVED OLD SWITCH. SNAPPED IN NEW SWITCH AND CONNECTED WIRE. REPLACED CONTROL PANEL AND UPPER PANEL.
the glass circular tray inside had cracked in half.It was of no use. I reordered another
The tray came within 5 days and I simply took it out of its well-packaged box and slipped it into my microwave. It is working just like new. I can't thank you all for being so punctual and reliable. better than having to buy a brand new microwave.
Removed one phillips head screw, removed old cover, then replaced new cover and screw. Very easy and Parts Select made it happen. Will deal with them again. Thanks Parts Select.