Fan motor stopped working.
I first unplugged the unit.
Secondly I unscrewed the back panel and removed it.
Third, I unplugged the fan, unscrewed it, removed it, and replaced it with the new fan motor.
I then plugged it to confirm that it worked and then put everything back together.
Parts Used:
Evaporator Fan Motor Kit
  • John from Clifton Heights, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
nosiy fan operation
most of the time spent on repair was removing the food from freezer compartment other than that removal of a couple screws and disconnecting and reconnecting wires not a huge ordeal
Parts Used:
Evaporator Fan Motor Kit
  • TOM from GRANVILLE, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken filler tube at threaded connection
After discovering that the water noise was coming from the rear of the refridgerator upon pulling it foward I discivered the connection line had broken. So i got a phillips screw driver and removed the the two mounting screws and saw it was one piece. I easliy found the part on PartSelect website and once I got I merely swaped them out and it works good as new!
Parts Used:
Ice Maker Water Fill Tube Kit
  • Matthew from Phoenix, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Filler tube broken and old tube frozen over
this is a snap! 2 screws an a nut to tighten and it works like a charm. the filler tube in my Kenmore refer had broken off in the back. ( really bad location to put this in the beginning) if you push the refer to close to the wall you can break it off easily. remove the water line by loosing the nut and remove the hose from the fill tube ( This assumes you have already turned of the water supply or you are standing in a large puddle)remove the 2 screws that hold the filler tube in place. pull out the old filler tube in and slightly upright motion. replace the new fill tube into the same hole and replace the screws. replace the hose and tighten the nut, turn the water back on and check for leaks your done !!
doesn't that feel great?
Parts Used:
Ice Maker Water Fill Tube Kit
  • Alan from Chino, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken Door Shelf Suport
Our trusty fridge is so old that I couldn't find any replacement parts on the manufacturer's website. Thanks to PartSelect, I was able to keep narrowing down my request until I found an illustration of a part that matched my dimensions exactly. Delivery was FAST. Within 10 minutes I had the old duct-taped shelf support gone and a perfect replacement part installed. Looks like new! I may be a 67-year old grandmother, but a pro couldn't have done it any faster or better. Thanks so much for your excellent website and prompt delivery!
Parts Used:
Door Shelf End Cap Set
  • Charlie Jeanne from Lafayette, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
botrailer with frig without a icemaker
got the icemaker kit and started to add it to the frig found problems with the adaption to the frig in back for water filler tube but was able to make it fit. had to make a connection outside to water line with copper pipe added to hose with claps and saddle valve, turned it on and had leaks due to the schedule copper was the thin wall type, got thicker type and installed it, no leaks, started making ice. it was nice to get the right kit to make things work out. thanks
Parts Used:
Add-On Icemaker Assembly
  • rich from racine, WI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers, Wrench (Adjustable)
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisy freezer evaporator fan motor
Removed the shelves from the freezer and the brackets holding it along with the covers for the light and plate for the ice maker (we don't have one). Pulled the ground wire from the tab off the port for the ice maker. Removed back plate exposing the fan motor and then the 4 hex screws holding on part #23 of the diagram which the fan motor is mounted to. Flipped it over, unscrewed the 2 hex screws from the fan motor mounting and removed it. Removed and replaced 3 wire connectors on new fan motor. Installed new fan motor and new grommets but used the old screws because the provided screws were larger. Pushed the new fan on to the motor shaft. Reassembled. Half hour most.
Parts Used:
Evaporator Fan Motor Kit
  • Lloyd from Long Beach, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the light socket broke apart
I took out the old socket by moving a clip. Reattached the electrical wires, clicked in the socket and that was it.
Parts Used:
Light Socket Kit
  • Elyse from Skokie, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fan was making alot of noise
I removed all the shelves and the back shelf hanger. Removed two screws on the back plate.Pulled it out.Removed the screws that hold the fan housing. Pulled it out so I could write down the three wires color and location.Unpluged them.Removed the old fan and installed the new one.and put everthing back together.
Parts Used:
Evaporator Fan Motor Kit
  • JERRY from ALBION, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Socket set
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Removed the old parts then connected the new parts.
The compressor immediately started when I plugged the refrigerator back in. Around 24 hours later the freezer compartment was at 0 degrees, and the refrigerator was at 35 degrees.
Parts Used:
Compressor Relay and Overload Kit
  • Jonathan from OLIVE BRANCH, MS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Shelf End Cap broke
This Job is a brease - less than 5 minutes.

Be carelful not to bend metal shelf rail -
Remove broken end cap and slide out metal rail.
You can clean parts before reinstalling.
I recommend slightly squeezing rail before reinstalling to tighten the contact points with plastic end caps.
slide metal rail into end caps (they should snap if contact is right) and secure with sticky tape (sticky tape is supplied with pair of end caps).
Reinstall rail with endcaps attached.
I even have one extra end cap left for another repair if neccessary!
Parts Used:
Door Shelf End Cap Set
  • Thomas from Danvers, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Installing old ice maker in new freezer
I was able to transfer my old ice maker from my old Roper Refrigerator/Freezer into my new Whirlpool Sidekick Freezer. Everything transferred directly except for the water fill tube. I ordered one on line and simply cut it to the right length, removed the cover plate inside the freezer compartment and the little sticker from the outside. Inserted tube and fastened in place with two screws (not provided but was able to use the screws that were in the holes inside the freezer before the ice maker went in. Works great. By not buying the ice maker with the freezer I saved a hundred bucks or so.
Parts Used:
Ice Maker Water Fill Tube Kit
  • Harry from Ten Mile, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replaced broken shelf supports
Took out old pieces and popped new ones in, just like that!
Parts Used:
Shelf Support Kit
  • Cheryl from Los Angeles, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fill tube on the icemaker was leaking.Looked at sears repair parts list and part was $62. I found the same part here for $4.99. Very easy to just remove the old part and replace it with the new. I also received the part in two days. Amazing!!!!
Simlpy removed two screws to remove the old part. replaced the new part and put the two screws in. Job finished.
Parts Used:
Ice Maker Water Fill Tube Kit
  • Walton from Woodland, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker motor excessive slip (essentially worn out) & contacts were worn
1 removed bottom off old ice maker (3 hex screws) and ice drop shield (white plastic ice flips over into ice holder, old unit had different drop angle, see how described below, but I just musled it off the old unit) 2 removed "ice sensing bar off new ice maker and rotated mechanical sensor to on (leatherman tiny flat head) 3 removed end cap from new ice maker, then loosened to large screws (Phillips, leatherman) for motor unit cover. This allowed removal of ice drop shield on new unit (two tabs, one at each end). 4 removed ice drop shield and installed old ice dropshield on new unit 5 tightened two endcap screws (Phillips/leatherman) and reinstalled end cap 6 installed old bottom unit/tray on new ice maker (3 screws) 7 ensured wiring matched and routed plug properly 8 installed unit slides in 9 plugged unit to existing plug 10 installed old wiring shield (1 hex screw). Waited two hours to verify water valve worked properly, although IR codes did indicate "okay". Machine has been making ice and IR sensor shuts it off properly. So far a success. I have many spare parts if I need to do further repairs including a new water solenoid. Only saying it was a bit difficult because of the parts exchange, in actuality for me it was really easy.
Parts Used:
Add-On Icemaker Assembly
  • Richard from Blue Ridge, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the RT20CKXAW00