Old plastic ring was damaged due to leaking icemaker causing door to open when ice dispensed.
No tool required! Pulled out tray, emptied ice into large bowl for reuse. Pushed in and pulled from inside the coil springed auger until could get old plastic ring off and put new one on. Useing care not to apply too much pressure to ice dispensing end so as not to break housing. Have to turn auger assembly at an angle to compress enough and get old ring off. Needs a little physical strenth & care not to force plastic housing to breaking point. Worked great reused saved ice. Took less than 10 minutes
I unboxed the new drawers, measured and cut some 1/8 plexiglass strips to fit. I then glued the strips on the inside of both drawers to strenghten. The original and replacement drawers lack strength at the corners and crack. This was the third set I have replaced. Should not happen again.
Water / Ice dispenser would not stop flowing / running
Our 20+ year old Maytag refrigerator suddenly started dispensing water one day without anyone near the refrigerator. Thankfully, my wife was nearby; my son temporarily solved the problem by shutting off water to the house. The ice dispenser unit has a "Lock" switch which turns off power to the ice & water dispenser. With the switch in the "lock" position, we were able to continue using the refrigerator (and turn the water back on) until I was able to get a replacement part.
The biggest hurdle that I encountered was removing the trim; I spent perhaps an hour and a half trying to figure it out. In the end it turned out to be easy and would have been perhaps half an hour job total had I known the trick. So... to remove the trim on a Maytag RSW2400, you remove a single Phillips head screw on the bottom of the trim. The trim then slides to the left and can be removed.
The next mistake I made was removing the entire dispenser unit. Instead, if you look closely, there are screws which may be used to disassemble part of it, leaving the ice/water dispenser housing mounted to the refrigerator door. This provides access to the ice/water actuator switch. Perform this disassembly and access to the switch becomes obvious.
The switch is held in place with a single Phillips screw. Make sure that you've disconnected the power to the fridge well before this point because, AFAICT, 120VAC flows through this switch! The switch that I replaced didn't appear to be in bad shape and, once removed, the switch seemed to work correctly when I tested it with an ohmmeter. I replaced it anyway.
Reassembly was straightforward and easy. Better still, ice and water are now dispensed correctly again.
Refrig began to trip the GFI circuit in the garage. When plugged into a house interior circuit the lights and fan ran but no cooling in either the freezer or frig.
First of all I want to thank Michael from Carlisle,PA and this site for publishing Michael's info on the wiring specifics on the new 3 connector Start Relay ( WP2262185 ). The original relay only has 2 connectors The 2 orange wires which are combined to one female connector need to be clipped and separated each to its own connector. Refer to Michael's blog as to which wire goes to which connector on the Start Relay. I replaced the Run Capacitor, Start Relay and Overload just to be safe. The Start Relay was the actual culprit.Thank you for an excellent website!
Refrigerator quit cooling and the freezer wasn't freezing anything
Order the part from the Internet on Sunday, it mailed out on Monday and I received it on Tuesday. I unplugged the fan then undone 3 screws that held the fan bracket to the refrigerator pulled it out unscrewed 3 more nuts and replaced the fan on the bracket and I cut the old wire plug off the old fan and with 2 wire nuts put it on my new fan. Replaced the fan and bracket back on the refrigerator plugged it in and it works like a new refrigerator.
I was told to order the run capacitor and the technician thought it would repair the refrigerator; but it did not. The appliance technician had to take the run capacitor off and install what he called a "hard start" and the refrigerator is operating right now.
Ice-maker tray wouldn't empty properly, so water spilled out of it and froze pieces of ice together, making a big glob of ice in the holding vessel for ice pieces.
Removed and replaced the old tray, which had lost its elasticity and wasn't emptying properly. This couldn't have been easier. Several years ago, we had the same problem, so I called a repair service and paid a dude about $85 to diagnose the cause and correct it. This time, based on observing that prior repairman, I ordered the replacement part for about $25, from this outfit, and repaired the fridge in less time (including time online) than previously spent finding a repair service and dealing with it.
After going to manufacturer's web site and customer service phone, was unable to locate the correct switch in the dispenser area on the door. Your web site had the picture of the switch and it was right on and in stock. Shipping was quick and inexpensive. Repair went quick and all is well.
took nut driver and removed screw holding valve to refrigerator removed valve. Swapped water lines from old valve to new valve,plugged in selonoid wire harness to new valve reattached the water valve to referigerator and turned water on and forgot it. No leaks,ice and water in 24 hrs.
Removed power, removed the ice maker being held with three screws. Replaced with old unit. This box was so old that I robbed parts from the old and placed them on the new unit. Mkes ice very good.