Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
freezer and refrigerator compartments not cold enough
Used the suggested problem list here to narrow down that the repair was most likely the run capacitor. Poped the new one in and I now have better control of my compartment ranges. I have a temperature gauge in each compartment. Check them every opening of the doors.
replaced relay switch when I finally got started to do the repair it took 15 minutes my biggest delay was no instructions were sent with the part and it took time to get some
Shelf studs broke several years ago and I had a problem locating them. Finally wised up and checked Part Direct and found them, ordered the kit w/ 12 pieces. Then quickly watched the installation video. Took less than 30 minutes to replace two different studs. Wife is very happy.
Simply took broken pieces of old stud out and replaced with the new ones. Used pliers to adjust them. Replace a freezer stud and a fridge stud.
I slid the bar into the end caps, then slid the end caps into the slots on the door. No tools were required. My fridge is old, and I was very pleased that I was able to find the part.
Not so good that was not the problem. Fan is not seized and all the lights work and display is not on but lights up as well. No start once plugged back in after 15 minutes of being unplugged. Nothing same no change.
inst said,"50 pct of the time this calls for new capacitor," so we changed the capacitor. Same prob. It also said,"25 pct of the time it's the bi-metal thermostat" So we ordered it. We removed the plastic rear panel from inside the freezer comp. using small nut driver. Here we found much ICE surrounding the defrost unit, three inches thick. We thawed the whole mess. and the freezer has worked fine ever since. I think my habit of getting ice cubes from the inside container rather than from the ice cube dispenser, had kep t the freezer door open too much, interfering with the normal defrost cycle and allowing ice to build up over time so that it finally defeated the system. My new rule, "get ice cubes only from the front."
Reviewed Youtube video as a reference. Unplugged refrigerator. Removed old defrost timer. Matched the color of the wiring harness to the diagram that came with the part. Attach new part to wiring harness.
Very easy. Left the front of the refrigerator so it is approx. 4 inches of the floor. (used a two by four. Removed the screws (one for each roller). Removed the rollers and replaced with new rollers. Reinstalled the screws with secures the rollers to the refrigerator. Done
refrigerator stopped cooling due to condenser over-heating
Pull refrigerator out to access back, unplug unit and remove the 3 .25" screws cut the power leads to motor and install new with easy to understand instructions provided with new motor. Plug refrigerator back in and enjoy your cold beverages once more. EASIEST REPAIR EVER.
Removed the access panel on back of unit located the Run Capacitor on the compressor and removed the bad one and put the new one on and pugged refrigerator back in and it started up and works fine now
Freezer made lots of Ice and Refrigerator didn't cool
The Defrost Timer is located in Refrigerator section (not the freezer) where your temperture guages are. Move panel and replace the non working Defrost Timer with the new one. It took my husband about 30-40 mins to fix. This was about 2 weeks ago and my Freezer and Refrigerator are working like new. I bought this Kenmore Reftigerator brand new in 1996 and I lost the manuel to it. Thanks to my daughter who found the Defrost Timer on the Internet, I thought I was going to have to buy a new one. This was real easy to fix. The instructions that came with the part was easy to understand and very self explanatory. It also had very good diagrams to follow.
After searching online to diagnose the issue with my refrigerator being warm and the freezer being cold and not shutting off to defrost I decided to get the defrost timer kit. The kit arrived within 2 day. With the directions included, after unplugging the appliance for safety, I installed it relatively quickly with only a screwdriver . I then plugged it back in and it immediately went to defrost. I thought, wow I have it fixed. Well unbeknownst to me it still didn't cool in the fridge area. After doing more internet research I found a suggestion to unplug the fridge for 24 hours to unthaw ice that may be lodged between the freezer and fridge that is blocking the distribution of cold air into the fridge. After doing this, it now works like a charm.