Door did not close by self the last 1/4 inch.
First I removed the top hinge cover plate. Then removed the three screws in the top hinge. I lifted the door off the lower hinge and laid the door on the kitchen counter. I removed the one screw holding the natural door closer part from the bottom of the door and installed the new part with the same screw. I then replaced the lower hinge pin with the new one. It just sets in place. I then repositioned the door and reinstalled the top hinge. the whole job took about 15 minutes after the refrig door had been emptied. The door works like new.
Removed shelf, removed 2 screws, pulled off face plate. Removed electrical connection to circuit board. Removed 3 screws holding part in place and pulled forward. Replaced door flap easily. Hardest part was getting dispenser mechanism back in place with the water tube routed through the right spot.
Defrost did not happen, expansion unit iced up, cooling was minimal.
Only had to remove 2 screws and slide the fan cover panel down and out, then lift out the coil cover panel. Then used a space heater to thaw the coils (block of ice) so that I could get to the defrost heating element (OK, so I was in a hurry. Could have just unplugged for a day an let it thaw on its own). Defrost heating element has just one connector (snaps in place), one thermo-switch (snaps onto coil) and one supporting retainer clip to disconnect. Literally under a minute at this point to remove the old one and replace it with the new one. I recommend two retainer clips to hold the new element in place, since the old element had sagged a lot with only one clip and that could have contributed to its demise. Reinstall the two panels, secure with the two screws, plug it back in, done deal. Works like new again. I was very impressed with these parts - they were exact and obviously factory replacements. It doesn't get any easier than this.
The Basket stops were crack and the freezer basket would fall out when the freezer dooor was opened.
First I compared the old parts and new parts to see if I had ordered the right thing then I inserted the new stop into the door. Since the stop has a lip that needs to fit into the slot I the door, I used a hammer to push the part up so it would lock into the hole. Very Simple
The Ice maker unit had to be removed and the shaft had to also be removed, which required dis-assembling the motor drive. The thickness of the shaft and the bearing fill cup prevents it from simply pushing it in place. Other than that I have Ice.
Used socket set to remove screws. Removed the wire harness, then removed lift arm from old ice maker and then put lift arm on the new ice maker. Reinstall wire harness then installed back in freeze with the screws. Video was very helpful. I will do business with Partselect in the future. Shipping was very fast. Thanks Partselect
This is an easy repair. It took me longer to remove the bins off the inside of the door and clean then up, then the actual repair. Remove the top hinge trim 1 Phillips screw. After the hinge trim is removed you'll see 3 hex screws. Remove the 3 screws. Hold and open the door half way, and lift up on the door. The door is not heavy. Use your kitchen table as a work bench. Place the door flat on the kitchen table . On the bottom of the door you'll see the "CLOSER" One screw removes it. Reverse operations and reassemble. Note: Put a little Vaseline grease on the pivot point. Thats it ... 15 minutes and your done plus you saved a $65.00 service call.
Watched video. Unplugged refrigerator and popped out switch. In plugged connector and pushed switch in place. Plugged in refrigerator and the light worked
Took a putty knife and Removed the old switch removed the spade terminals from the old switch and replaced them on the new switch and just pushed the new switch back in place
Removed the 3 screws that hold the ice maker in place and remove the cover and level wire. Put the cover and wire on new part and install the 3 screws. Had ice within 1 hour. A very easy job for the do it yourselfer. Suspect the heat coil that melts the cubes was not working in the old unit and cubes stayed in the tray.
This was the third icemaker replaced since January 1999. Improvement need to be made in the design of the icemaker so that more than 2-3 years of life is available. The most difficult part was disconnecting the power plug in the back of the icemaker. You must squeeze the upper and lower tabs together and pull out at the same time to disconnect. Once this is done, take out one nut head screw, lift up on the icemaker and remove from the hanger. Be careful that you don't break the plastic tabs on the hangers. Replace new icemaker in reverse, feed water supply where it must go in the back, resnap onto hangers, replace the nut head screw and snap in the power plug. It took about 2 hours before the icemaker began making ice. It has been working fine ever since. PS. I saved about $200.00 over having a repairman come in and replace the unit.
leaking ice maker,big chunks ot ice were forming and had to remove them 2-3 times a day
removed old ice maker by taking out a couple of screws in the back of freezer,when new ice maker arrived i saw that it didn't have the same hose apparatus as old one so I easily took apart old one then took apart new one and switched them out-very-- easily done for a 61 yr old lady I might add-- also had to reinstall ice maker arm off old ice maker as new one does not come with one Then installed new ice maker in freezer I am very very pleased,sure saved a lot of money doing it my self