Ice maker not making Ice
Unscrewed (loosen) screws lifted unit out unplugged electrical connection. plugged in unit hung on screws tightened screws and had ice in less then 1 hour. Rick
Parts Used:
Refrigerator Ice Maker Assembly
  • Colline from PENDLETON, OR
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light blub blew
unplug power from ref removed old light socket only difference wired a little different checked new socket compaired to old checked terminal ends small big looked at wires big,little plugged up put in new light blub plugged ref power back on work power off pushed socket bac in power on works
Parts Used:
Light Socket
  • earl a from GIRDLER, KY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
4 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
made lots of noise
Loosen two screws, unplug power, lift it off, put new one on and make sure water chute is correct place, tighten screws!
Parts Used:
Refrigerator Ice Maker Assembly
  • Kelly from GILBERT, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator shelf guard kept falling off, causing everything to come crashing down
Simply popped the new end caps into place with the old guard and now it is tight and secure. Easy Peasy. Of course all this is after the operator at PartSelect ordered the right part for me; I had ordered the freezer door end cap, not what I wanted. I received the correct part the very next morning. Returning the wrong part was a breeze too.
Parts Used:
Door Shelf End Cap - Left or Right Side
  • Kathryn from Anadarko, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the freezer would stick in defrost and not come out
Removed the vent cover at the bottom. Removed the screws. disconected the harnes and put the new timer in. This was a very easy fix. Thank You!
Parts Used:
Defrost Timer - 60Hz 120V
  • carol from woodland, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
gasket needed replaced
took off the old one installed the new one
Parts Used:
Fresh Food Door Gasket
  • toney from poplar bluff, MO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
end piece broken that held bar on freezer door shelf
attached the bar to the end piece and slipped it into the proper opening. Easy I ordered the piece one morning and received it the next morning. Great service.
Parts Used:
Door Shelf End Cap - Left or Right Side
  • Betty from Seal Beach, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator was not cooling and the motor was running constantly
Having tried PartSelect.com before, I was very comfortable with the process. Input my symptoms and the feed back I received was that one of the 2 things (Defrost Timer or Defrost Thermostat)might need replacement. Since the cost was not much and over night shipping would cost more than the product, I decided to order both the parts. Changing parts was a breeze. The instructions posted by others on your web site were very easy to follow. You guys save me a bundle every time I have any thing going worng with any of my appliances.
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Anil from Somerset, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evaporator In Freezer Freezing Up, Fridge Warm
Removed shelf brackets to allow the removal of the evaporator sheetmetal cover. Unpluged wires to thermostat ,removed defrost timer and plugged in new timer,(front left lower kick panel). Cut and resoldered wires to new thermostat reinstalled thermostat and cover in reverse order. I knew what parts I needed and how to repair the unit,however your customer comments were spot on and would help anyone perform a successful repair (you provide a helpful service for the public)
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • DONALD from MECHANICSVILLE, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
first fresh food too hot, then freezer too hot
Based on the website I decided it was most probably the defrost timer, and that was correct. I ordered it, watched the video, and two days later the part was at my door. Took the nut driver, removed 4 screws, then removed the old defrost timer, installed the new one, re-installed the whole plastic assembly with the four screws, and done!!! Couldn't have been easier.
Parts Used:
Defrost Timer - 60Hz 120V
  • Rita from Lake Luzerne, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice machine was now working correctly
watched the video (VERY helpful) and then removed the old icemaker and replaced it with the new one. Difficult only because of the small working space in the side by side freezer plus you can't see what you're doing when you tighten the screws. Working like a charm now.
Parts Used:
Replacement Ice Maker
  • colleen from salt lake city, UT
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set, Wrench (Adjustable)
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Frost in freezer, fridge not cold
From most posts I've read, the defrost timer was the culprit so I blindly ordered one. Easy install but did not fix the problem so I broke out the ohm meter. The only other 2 items it could be all tested good with my meter so I bypassed the defrost thermostat (per forum help...actually quite easy)and it defrosted fine, which told me I needed a new defrost thermostat. Installed fairly easy and problem gone.
Parts Used:
Defrost Timer - 60Hz 120V
  • Bob from Pinole, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker wasn't making ice
Occasionally, we'd get one batch of ice cubes and a frozen lake of water in the bottom of the ice tray.

The installation was easy and I won't bother duplicating the comments of others who have installed this part.

One word of caution: The ice maker contains a heating element on the bottom. That element is apparently live even when the ice bar is in the upper (off) position. When I unscrewed the old ice maker and went to lift it off the bolts, I severely burned my finger on the bottom of the old ice maker because apparently I started the repair in the middle of the heating cycle.

I highly recommend that you unplug the ice maker entirely before doing the replacement and gingerly ensure that the unit isn't hot before touching it. You'll save yourself a nasty burn.
Parts Used:
Replacement Ice Maker
  • Scott from Grayson, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Retaining bar for bottle shelf in door missing
Placed end cap on one end of rack and attached to one side of the door by applying hand pressure.
Inserted the other end of the rack into the end cap'
and again applied hand pressure to insert into slot, Repairs completed.
Parts Used:
Door Shelf Retainer Bar - Cut to Fit Door Shelf End Cap - Left or Right Side
  • Oliver from Garden Grove, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the refrig was in storage for about a year, the freezer door warped
removed freezer door and installed the new one. This was a pretty easy thing to do, although putting the old handle on the new door was a challenge. No knowing that there is a plastic piece holding the top of the handle i broke the that piece and had to order another one. Mean while the freezer was making alot of frost inside, so that had to be cleaned after the new part came.
Parts Used:
Handle Mounting Block
  • Jeffery from Phillipsburg, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!