Needed to repair and replace dryer motor pulley and pully
this was very was very easy. But I deviated from the You Tube instructions. One to release the motor pulley. I needed to use 2 adjustable wrenches for a longer lever. I needed to use a hammer to help release pulley. Second to remove the dryer cable I needed to use a small screw driver to aid in the release. ---- the part from the company was a perfect fit.
*as with all electrical repairs I unplugged dryer from the outlet*
I disconnected the wires to the heating element, removed the 2 nut screws holding the heating element in place and removed the defective heating element. It looked like the heating element had darkened on the lower end and the wire terminals definitely looked like they had built some resistance that lead to the connection wire melting.
I slid the new heating element in and replaced the 2 screws. I cut the melted portion of the connection wire about 1/2" beyond the melted area and stripped the wire jacket exposing clean wire. I took the connection kit & clean wire lead, divided the wires into 2 groups on each end and braided them together and twisted them to a hand tight grouping. I then took the lead cap and twisted into onto the braided wire connection until it was also hand tight and snug.
I then reconnected the heating element connection wire back to the terminal end of the heating element and made sure all connections were snug.
I plugged the dryer back in, reset the dryer by turning the dial to a timed setting then back to off. I set the heat to low turned the dial to a time dry and turned on the dryer to ensure the element heated up and that the wired connection was secure. After 20 - 30 seconds, the element maintained heat and no issues were found with the fixed wire.
I replaced the dryer back and all screws and reconnected the vent hose. Dryer has worked great for the last few weeks with no issues. I was really surprised it was that easy to fix.
I removed the hex head screws from the back of the dryer and removed the back panel, after unplugging the dryer. I tested the various electrical components until I found that the upper limit temp fuse had gone out. Came to partselect.com and found the kit I needed and ordered it. When it came in, I replaced the upper temp limit fuse, and the other parts that came with the kit. I also, since the back was open, used the opportunity to vacuum out the blower fan and as much of the lint as I could get to. Dryer works great now!
Poor drying and took excessive amount of time to complete partially dried loads
Took back cover off. Cleaned out the lint that had built up inside the dryer. Replaced the lint trap housing and lint chute seals. Also replaced the drying vent hose. Works great now.
Dryer was not heating and sometimes would not start at all
Unplugged dryer Removed back Removed knob and screw from front and 2 screws from the timer in the back unplugged one wire at a time and replaced one at a time. Dryer working great.
My dryer was running way too hot and the temperature settings didn't make any difference. Clothes were shrinking and coming out almost scalding hot. I followed simple directions posted on you tube for troubleshooting this problem. I checked that there were no lint blockages, visually inspected all connections and hardware. All seemed good. Metered out all thermostats and fuses. Everything checked good for continuity. For the reset-able thermostats, I heated them on a hot plate to verify that the normally closed switches opened near their specified temperatures. Dont do this for the non-resetable fuses and thermostats. If you're not sure, avoid this step. Only the hi-limit thermostat seemed to open a little higher than expected but I couldn't with 100% accuracy determine the exact temp it opened. Made sure the heating element wasn't shorted in its housing or that too might give the dryer the same symptoms. That checked good too. Only thing left I could think of was to change that hi-limit thermostat. Ordered part, removed and replaced. Perfect fit. Op-checked good. All heat settings now operate normally. No more shrunken clothes that are too hot to touch even on the lowest setting lol. Hope this helps, happy hunting.
The dryer stopped heating, it would only blow cold air. I removed the back panel and tested the thermal fuse with a dmm. The fuse was open, so it was bad and I needed a new one. I tested the thermostat and the dmm measured continuity across the terminals, so I thought it was good, bad assumption. I ordered a thermal fuse from partsselect and it came with a thermostat. Like a dummy, I only installed the fuse. The 1st time I ran the dryer the fuse blew again, because the thermostat was bad. So, moral of the story, install both parts.
Two Phillips screws, and 2 5/16 bolts and the dryer is open for this repair. Remove the drum and note the placement of the drive belt. Then using a pipe wrench grab the rear plastic fan housing, at the rear of the motor shaft, and turn the front of the motor shaft CLOCKWISE. If the Fan is ceased (as it was in my case) you will need to use locking vice grips (at least 3 or 4 between the fan blades to stop the fan blades from turning on the rear shaft.) while your turning the front of the motor's shaft. If done properly, you should have about 25-30 turns before the motor is free for replacement. Once this is accomplished, mounting the new motor back into the dryer is a simple matter of reversing your steps. But keep note of the belt placement and the motor wiring placement before starting.
I did my repair alone by myself after viewing a short video online at partselect.com The man in the video showed every step slowly and professionally. I took some extra time to clean the dust off behind the back of Dryer while I had it open for fixing.....thanks for your help and it saved me over $190 plus which I was quoted by technician for estimate and parts. I paid $43.00 for my parts...both High limit and Cycling thermostats were replaced. My wife told me good job honey ! You can do it too.
Dryer ran with no heat. Replaced the Thermal Fuse and when that didn't fix the problem discovered the element was burned. Easy fix except the F-disconnect fitting broke when I tried to remove it and male fitting on the heating element is 0.375 and all I could find were 0.250 F-disconnect fittings. I finally found a supplier who had a 0.375 fitting and the repair took 10 minutes after that. The online videos at PartSelect are excellent.