Enter the code USA15 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on July 1 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Dryer kept throwing the E1 error indicating the thermistor needed replacement
Unplugged the Dryer first. Removed the two screws from the bottom panel using a 1/4 socket and removed the panel by pulling down and out. Reached behind the blower and removed the connectors from the old thermistor and then the thermistor itself by removing the two 1/4 inch hex head screws. Replaced with new part and after screwing back in, reconnected the wires and replaced the panel. From start to finish, it took me about 20 minutes.
(Always unplug dryer before making any repairs) I opened the dryer and checked the heating element. Making sure that the connection was good and nothing was damaged, I determined the problem was overheated wires. They melted and lots connection. I replaced them with the heating element wire connection kit. Easy to install and simple to get right. I cleaned the dryer again with a vaccum cleaner, removing all the lint, and checked the vents, making sure they were clear...I turned the breaker on (it was tripped when the dryer overheated)and everything worked great.
The door catch on our Whirlpool Dryer had given out.
The repair cost us less than $9.00 and about 1 minute to repair. You can only imagine how much a tech would have charged us!! We are so very happy that we discovered this site . The instruction video they offered, the customer service via their website AND quick delivery of the part, has insured them that we will be repeat customers. Thanks so much !!!!! Bravo! Annie & Peter in , Nevada
I googled the problem and determined that the thermistor was faulty. I found your web site from which I ordered the replacement part. The part arrived within a week. The replacement was not particularly difficult, but the space was very tight (without removing more panels and covers). I just kept at it and got it installed and the dryer works fine now. There are several pertinent videos on you tube, none of which were my particular model, but the combination of them led me to a successful installation.
Door catch on dryer stopped catching (meaning the door would not stay closed)
I placed the putty knife on the top part of the door catch and when that came loose I placed the putty knife on the bottom of the door catch and pushed on the putty knife and the door catch came out of its place. I then just popped the new door catch in place. Total repair time 45 seconds. The door now closes.
Took a screwdriver and bent wings out a little and then was able to get hold of it with a pair of pliers. Then just put the new unit in the opening and tapped it in. If I had a good pair of needle pliers, it would not have been necessary for the screwdriver.
Used screwdriver to remove old catch as shown via video from manufacture and snapped in new catch. Very easy to do and saved big bucks by doing myself.
Pretty easy repair and I am not very handy. I believe they engineer these machines so you hire someone to do the job. They could place that part in an area where it is easier to get to, like a door on the side or something
Message indicated something amiss in the motor circuit. Followed Instructions in the on-board manual. Turned out to be the internal-bias thermostat, and the exhaust air thermistor both. Changed faulty parts, cleaned lint from the system and we are off and running again. Thank You. DW Pranger