Models > M8RXEGMAB00 > Instructions

M8RXEGMAB00 Maytag Refrigerator - Instructions

All Instructions for the M8RXEGMAB00
106 - 120 of 553
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
the light socket broke apart
I took out the old socket by moving a clip. Reattached the electrical wires, clicked in the socket and that was it.
Parts Used:
Light Socket Kit
  • Elyse from Skokie, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker quit
i noticed that no water was getting to the ice maker. rather than messing around with parts, i bought the entire unit. easy to remove old one and install new one. thanks...ice started again in about an hour. unit cost less than a service call!
Parts Used:
Replacement Ice Maker
  • Tim from Ewing, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
replaced non-functional ice maker
After first unplugging the refrigerator from it's electrical power source,I removed the lower screw of the ice making unit with a nut driver. I then loosened the upper two screws which hold the retainer clips that secure the unit tight to the freezer wall. I then lifted the unit upward and outward a few inches to allow access to the wire harness. I unplugged the haness from rear of the freezer and removed the unit completely.
To install just reverse the procedure.
Parts Used:
Replacement Ice Maker
  • Richard from Troy, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker stopped making ice.
Unplug power to refridg/freezer. Removed the screw in rt. rear bottom of ice maker to remove. After removing slightly, unplug pigtail. Remove ice maker completely. Remove large square cover from left side to expose motor. Remove screws to remove motor. Replce with new. Replace ice maker to freezer, plug pigtail back in, put screw back in rt rear bottom, plug refridg/freezer back into power source. Ice was making in about 2 1/2 hours.
Parts Used:
Icemaker Motor Kit
  • Martin from Palm Coast, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice tray leaking
Super! It was so fast and easy to fix. Receive my kit in three days and save a lot of money not having to have a repairman come and do it!
Parts Used:
Replacement Ice Maker
  • Linda from Santa Maria, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
9 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker motor quit
This was a snap. Loosened 3 screws, removed
old ice maker. Made cutout for water chute. Plugged in
wiring harness plug. Installed new ice maker. Tightened 3 screws.

These brain surgeons that charge $80.00 just to show up at my house to repair an appliance are history.
Parts Used:
Replacement Ice Maker
  • David from Selma, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer work perfectly, Refrigerator Stopped getting cold, water line froze, there was ice Forming around the condenser in the bottom of the refrigerator behind the drawers
Freezer worked great, refrigerator stopped getting cold and lots of ice formed around the condenser on the bottom of the refrigerator.
First I had a serious ice issue, ice build up around the bottom of the refrigerator and all through the cold air vents, condenser and cooling fan. I unplugged of the fridg and let defrost over night. I also took all the cold air vents out and cleaned them.
Then I followed the switch install video very simple switch install. Now the Refrigerator works Great nice and cold.
Parts Used:
Bi-Metal Defrost Thermostat
  • Richard from STATEN ISLAND, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator freezer stopped cooling
Prior to ordering I removed freezer panel and checked for ice build up and fan functionality. Then removed rear panel cleaned lint from everything pulled front panel vacuumed out the condenser. Plugged back in and all seems to work with the exception of compressor. I have a little experience so googled in model number and your site popped up. I looked up part and the site gave me a percentage loved that. I ordered wish I would have rushed shipping as took about 10 days. Installed in less than 30 minutes and all runs great ??
Parts Used:
Capacitor Refrigerator Compressor Start Relay
  • Robert from COALINGA, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Clicking & popping for about 30 sec. when compressor starts
As shown on the YouTube link sent with email receipt.
Removed back panel. Removed the clip securing the parts with long nose pliers. Unplugged the old, replugged the new. Replaced the clip to secure.

Unfortunately, the capacitor and relay did not fix the loud clicking issue.
Parts Used:
Capacitor Refrigerator Compressor Start Relay
  • Michael from SCOTTSDALE, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer was working fine but refrigerator would not go below 45 degrees
Removed back panel inside freezer replaced fan motor reinstalled panel and was done in about 40 minutes the video on part select explains the repair very accurately
Parts Used:
Evaporator Fan Motor
  • Christopher from CASTAIC, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
intermittent clicking noise; otherwise fridge seemed to be working fine
Googled "intermittent clicking noise" or something similar and consensus was it was either the capacitor or compressor start relay. You-tubed videos on how to replace these. Looked easy. Just unplug them from the condenser and replace. Contacted Part Select and staff said 50% of the the time it was the capacitor, 50% of the time it was the relay. I was in a time crunch so I ordered both and they came in a couple of days. I replaced the capacitor but the clicking noise continued. I replaced the relay and problem solved! Maybe I could have gotten away with just replacing the relay, but I had them both by then and figured with a 10 year old fridge, better replace them both at the same time and be done with the problem. So far, so good.
Parts Used:
Capacitor Refrigerator Compressor Start Relay
  • Peter from EUGENE, OR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Random clicking noise
The toughest part was pulling the refrigerator from the wall....After removing the back-bottom access panel the compressor is right there with the Start-Dev and Cap..Took a few min to remove and install new parts....Very Simple and works great...no more clicking..
Parts Used:
Capacitor Refrigerator Compressor Start Relay
  • Mark from SAN DIEGO, CA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Temp was -20 to -30 degrees F. and did not defrost because of the extreme low temperatures.
The Video on U tube was helpful. I have a side by side model and it was difficult to work in such tight quarters to attach the new part . I found that by removing the cable assembly it was much easier to attach (cut and crimp) the new part on the outside , then reinsert the assembly. The new part resolved my problem. Don't panic when you try and remove the cable assembly. Hope this is helpful.
Parts Used:
Bi-Metal Defrost Thermostat
  • George from ENDWELL, NY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Not getting cold
Followed instructions on your website
Parts Used:
Evaporator Fan Motor
  • John from PHILADELPHIA, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker was leaking and had metal in the ice
Removed the screws and disconnected the electric. I put the proper electric harness on and went to fit the unit in but it didn't fit. Until I figured out that you have to use the clips from the old unit that hold the unit in place. The actually hang on them. Once I figured it out it was easy.
Parts Used:
Replacement Ice Maker
  • Charles from Newark, DE
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the M8RXEGMAB00