washer stopped spinng
I replace the belts - 5 min I tried to replace the glides...I couldn't figure out how to do that..I took out the motor and and the glide mechanism...but I could not get glide braket separate from the motor mount..so i did not do this I replace the springs and added 1 extra sping...3 instead of 2..it worked
The dryer would start to heat then the heat would stop
I changed out the cycling thermostat and the high limit thermostat. Mainly because that was what my research indicated was the problem. I then found some more information online that indicated the gas solenoid valves were bad. I ordered them from you and replaced them. The problem was fixed.
In order to replace the valves you need to remove the top panel. Two screws at the top of the front door assembly hold it on. Remove the screws, lift up on the front panel door assembly and move it to the side. The drum will rest in place. In the lower left corner, under the drum, you will see the solenoids. Two screws attach a plate that holds down the solenoids. Take the hold down plate off, disconnect the control wires attached to the solenoids and lift out the solenoid/control valves. To assemble everything, work backwards to the start. Good Luck
Loosened the hose clamp, removed the injector valve and injector nozzle assembly, replaced both and tightened with new hose clamp. Fixed the problem for less than $20!! Washing machine is 20 years old and this was the first problem--hopefully it is now good for another 20 years!
dryer would get hot for a while, then quit heating
After reading about other people with this same problem I took a chance that this would be what was wrong with my dryer.I took off the front cover of the dryer by removing two screws. I located the faulty coils and simply plugged in the 2 new coils Tah-dah Probably coud have been done without even removing the front panel, but since it was off I vacuumed out the lint ( actually my husband did all of the above, but I tell a better tale than he does and I diagnosed the problem and ordered theparts)
First I removed the screws that held the side panels on at the bottom, then I removed the screws that held the front panel on and removed the panel. I removed the agitator, loosened the retaining nut with a hammer and a punch, removed the bolts holding the tub springs, removed the bolts for the top panel and flipped it out of the way. Then I removed the clamp for the inner tub and pulled it out, then I pulled the outer tub out. Then I removed the seal and scrubbed the rust off the seal mating area, then installed the new seal and re-assembled the washer. It works perfectly now and no longer leaks and it is over 20 years old. This is the first bit of problem we have had out of this machine, the lonely Maytag repairman commercials are true.
Water was not being removed from the wash tub after the spin cycle
I loosened three screws to relieve the belt tension and removed the belt from the pump drive pulley. After removing the water from the wash tub I removed the intake and output hoses from the pump. I next removed the mounting screws and removed the pump. I attached the new pump loosely and re-attached the belt. I moved the pump to tighten the belt tension and tightened the mounting screws. I re-attached the hoses, filled with water, checked for leaks and replaced the front panel.
I used my screw driver to pry the old female end of the latch from the dryer unit. I forced the new female part of the latch into the hole and bang...45 seconds later the door closed securely --like new!
This was a pretty simple repair. In this case, the part purchased here was not the actual problem, but had to be disturbed to fix another problem. After many years, corrosion and exhaustion of grease caused the bushing on the agitator shaft to seize, and the belts to slip. In this model machine, the bushing is accessed by first removing the agitator, which is held on by a single 1/4 inch set screw, and then removing the agitator seal, which is held in by a little spring clip on top of a washer. It's soft rubber, and you will probably need a small screwdriver or pocket knife to pry it out. In this case, the bushing was not too bad, so I was able to clean the hardened grease out and free it up with a little oil, using vise grips to rotate the agitator shaft, until the oil worked in enough.
Since seals don't like to be disturbed and reinstalled, and this one requires some prying to get out, I bought a new seal, even though the old one did not leak when I temporarily reinstalled it. There is a spring inside the seal, and it is packed with grease. The new seal comes with the spring and the grease already in it, so all that is needed is to slip it over the shaft (the top has some print embossed on it, making it easy to remember which is the top), press the washer down on top of it, and replace the spring clip.Slip the agitator back on its shaft and retighten the set screw, and you're back in business.
Run the machine, and check the area where the transmission enters the bottom of the tub. There's a little weep hole there, and if the seal leaks, you'll see water coming out there.
Intermittent or no gas ignition, HSI ignightor working
Removed front of gas dryer and cleaned all lint out. Checked HSI, and cleaned flame sensor. Split (3 terminal) gas coil terminals were intermittent. Read about 700 ohms across outer two terminals, but center terminal to either outer terminal was open (Infiniti on meter) 2 terminal coil measured about 550 ohms. 3 terminal coil should read about 700 ohms across outer terminals, and about 1.5K ohms center to outer terminals. Unscrewed index cover plate and replaced coil, 2 terminal coil was okay. Reassembled and finished 12 loads of laundry no problems at all.
Washer was leaking water onto the floor underneath
Pryed the front cover off and set it aside. I pulled the top cover off by removing the 1/2" hex screws under the front cover and hinged it back. Removed the agitator set screw with a 1/4" hex nut driver and pulled out the agitator assembly. Had to remove the nut that holds the hub assembly in by using a hammer and punch. There is not much room in the tub so be careful you don't hit the sides. It goes off by turning it clockwise. Then the splash guard comes off and then the inner tub with the top gasket and ring can be lifted out of the washer. The tapered cork covered hub was exposed and it also had to be removed with a hammer and punch clockwise after removing the torx set screw on the side of the hub. The rubber seal was now able to be removed under the hub and on top of the bearing on the outer tub. I had to clean all the accumulated scale off seal and bearing surfaces before putting new parts in (rubber seal, hub assembly, and new locking nut). Everything went back easily. Should be good for another 5-10 years...
First it was a process of alimination to find out why it was dropping out. After the problem was found it was just a matter of replacing the holding coil on the gas valve. Thank you fred kenney sr
1 Disconnect dryer from electrical outlet 2 remove vent pipe 3 Tilt dryer backwards and remove front cover bottom 2 philips screws. 4 remove lint assembly and then the fan blower housing with nut driver. 5 with pliers remove retainer clip from fan 6 remove snap ring with pliers or a flat blade screw driver will also work. 7 remove fan at the same time I replaced the front glides if you do not want to do this then reinstall in reverse order and job is complete.
for glide replacement 1 remove the 4 screws holding the outer ring to the frame of the dryer. 2 drill out old rivits from the back side and then knock out. be careful to only drill rivit and not into metal frame 3 install new new glides makesure you install in correct direction. 4 install pop rivets with stud end on top side of glide. pushing rivet through glide and into the frame ring. 5 pop rivits and make sure they are secure. 6 reinstall ring making sure seal is around ring correctly 7 reintal 4 screws. 8 follow reassembly of blower and lint housing if you changed the fan. if not then just the lint assembly.
good luck the job is really easy and you will save yourself some money
(I knew the gas coils were bad, since the gas ignitor would glow brightly as the burner attempted to ignite. So I knew everything except the gas valve was operating normally.)
Unplug the electrical cord to the dryer. Remove the front access panel. Remove the retainer clip for the gas coils (2 screws). Remove the coils and unplug the electrical connections. Connect the new coils to their respective electricl connections. Slide the nes coils back onto their respective posts on the gas valve. Replace the retainer clip, and 2 screws to hold it in place. (I then plugged the dryer back into the wall outlet to visually check the burner operation) Everything worked fine so I then replaced the front panel.