Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
washer stopped spinng
I replace the belts - 5 min I tried to replace the glides...I couldn't figure out how to do that..I took out the motor and and the glide mechanism...but I could not get glide braket separate from the motor mount..so i did not do this I replace the springs and added 1 extra sping...3 instead of 2..it worked
The dryer would start to heat then the heat would stop
I changed out the cycling thermostat and the high limit thermostat. Mainly because that was what my research indicated was the problem. I then found some more information online that indicated the gas solenoid valves were bad. I ordered them from you and replaced them. The problem was fixed.
In order to replace the valves you need to remove the top panel. Two screws at the top of the front door assembly hold it on. Remove the screws, lift up on the front panel door assembly and move it to the side. The drum will rest in place. In the lower left corner, under the drum, you will see the solenoids. Two screws attach a plate that holds down the solenoids. Take the hold down plate off, disconnect the control wires attached to the solenoids and lift out the solenoid/control valves. To assemble everything, work backwards to the start. Good Luck
dryer would get hot for a while, then quit heating
After reading about other people with this same problem I took a chance that this would be what was wrong with my dryer.I took off the front cover of the dryer by removing two screws. I located the faulty coils and simply plugged in the 2 new coils Tah-dah Probably coud have been done without even removing the front panel, but since it was off I vacuumed out the lint ( actually my husband did all of the above, but I tell a better tale than he does and I diagnosed the problem and ordered theparts)
First I removed the screws that held the side panels on at the bottom, then I removed the screws that held the front panel on and removed the panel. I removed the agitator, loosened the retaining nut with a hammer and a punch, removed the bolts holding the tub springs, removed the bolts for the top panel and flipped it out of the way. Then I removed the clamp for the inner tub and pulled it out, then I pulled the outer tub out. Then I removed the seal and scrubbed the rust off the seal mating area, then installed the new seal and re-assembled the washer. It works perfectly now and no longer leaks and it is over 20 years old. This is the first bit of problem we have had out of this machine, the lonely Maytag repairman commercials are true.
Water was not being removed from the wash tub after the spin cycle
I loosened three screws to relieve the belt tension and removed the belt from the pump drive pulley. After removing the water from the wash tub I removed the intake and output hoses from the pump. I next removed the mounting screws and removed the pump. I attached the new pump loosely and re-attached the belt. I moved the pump to tighten the belt tension and tightened the mounting screws. I re-attached the hoses, filled with water, checked for leaks and replaced the front panel.
The washing machine would only fill with cold water. This could be a problem with the controls, the wiring or the valve where the external hoses connect. Various tests, which only those with the proper skills & equipment should perform, revealed that the water valve hot side was not opening. UNPLUG the washing machine before doing any work and especially before opening any access panels. NOTE: Label all fasteners & other connections you remove so you know where they should go back. WITH the Washing Machine UNPLUGGED from the wall outlet, I unscrewed the external hot & cold hoses (make sure the water is turned off first!). I unscrewed the panel that holds the valve in a recess in the back of the machine. On this machine, the panel pulls out of the back with the valve attached to it. So I pulled the panel/valve assembly out of the recess and disconnected its electrical connectors (double-check the washing machine is unplugged before doing this). I also disconnected the internal hose that leads from the valve. Finally, I detached the valve from the panel. Installation is the reverse of removal, although it is a good idea to use a new spring clip or hose clamp, whichever you have, to attach the internal hose to your new valve. Once the valve assembly is properly installed, connect your external hoses, double-checking for hot & cold sides carefully, turn the water on and check for leaks. When all that is ok, plug the washer in and test it.
Intermittent or no gas ignition, HSI ignightor working
Removed front of gas dryer and cleaned all lint out. Checked HSI, and cleaned flame sensor. Split (3 terminal) gas coil terminals were intermittent. Read about 700 ohms across outer two terminals, but center terminal to either outer terminal was open (Infiniti on meter) 2 terminal coil measured about 550 ohms. 3 terminal coil should read about 700 ohms across outer terminals, and about 1.5K ohms center to outer terminals. Unscrewed index cover plate and replaced coil, 2 terminal coil was okay. Reassembled and finished 12 loads of laundry no problems at all.
Washer was leaking water onto the floor underneath
Pryed the front cover off and set it aside. I pulled the top cover off by removing the 1/2" hex screws under the front cover and hinged it back. Removed the agitator set screw with a 1/4" hex nut driver and pulled out the agitator assembly. Had to remove the nut that holds the hub assembly in by using a hammer and punch. There is not much room in the tub so be careful you don't hit the sides. It goes off by turning it clockwise. Then the splash guard comes off and then the inner tub with the top gasket and ring can be lifted out of the washer. The tapered cork covered hub was exposed and it also had to be removed with a hammer and punch clockwise after removing the torx set screw on the side of the hub. The rubber seal was now able to be removed under the hub and on top of the bearing on the outer tub. I had to clean all the accumulated scale off seal and bearing surfaces before putting new parts in (rubber seal, hub assembly, and new locking nut). Everything went back easily. Should be good for another 5-10 years...
After making sure the lines and screens are clean, and there is good water flow thru the hoses to the valves, and there is power to the valve solenoids, (which can be detected by setting to fill and pulling out on the start knob), and hearing a "click" at the valve, you can summize that the valve is weak, or partially blocked internally. Replace the valve by unpluging the power cord to the machine. Remove the hoses. Remove the screw that attaches the valve mounting plate. Pull the plate and valve out and remove the screw that attaches the valve to the plate. Unplug the wires from the solenoides,[IMPORTANT] noting which wires go to each valve. Remove the rubber hose on top of the valve by squeezing the hose clamp with a pair of pliers, and sliding the clamp up the hose. Now you can pull the hose off. Install the new valve in the reverse order.
shaft lock was damaged and agitator would not stay down in proper location
Made a 4 prong wrench from a 2" pipe coupling to remove retaining nut. Had to tap retaining washer a few times with hammer and after that it came off very easy. All other work was very easy. parts went together with ease. Saved company several $'s as we were told it was not recomended to repair and should replace washer. Under $100 for parts and a couple hours labor.
First it was a process of alimination to find out why it was dropping out. After the problem was found it was just a matter of replacing the holding coil on the gas valve. Thank you fred kenney sr
1 Disconnect dryer from electrical outlet 2 remove vent pipe 3 Tilt dryer backwards and remove front cover bottom 2 philips screws. 4 remove lint assembly and then the fan blower housing with nut driver. 5 with pliers remove retainer clip from fan 6 remove snap ring with pliers or a flat blade screw driver will also work. 7 remove fan at the same time I replaced the front glides if you do not want to do this then reinstall in reverse order and job is complete.
for glide replacement 1 remove the 4 screws holding the outer ring to the frame of the dryer. 2 drill out old rivits from the back side and then knock out. be careful to only drill rivit and not into metal frame 3 install new new glides makesure you install in correct direction. 4 install pop rivets with stud end on top side of glide. pushing rivet through glide and into the frame ring. 5 pop rivits and make sure they are secure. 6 reinstall ring making sure seal is around ring correctly 7 reintal 4 screws. 8 follow reassembly of blower and lint housing if you changed the fan. if not then just the lint assembly.
good luck the job is really easy and you will save yourself some money
(I knew the gas coils were bad, since the gas ignitor would glow brightly as the burner attempted to ignite. So I knew everything except the gas valve was operating normally.)
Unplug the electrical cord to the dryer. Remove the front access panel. Remove the retainer clip for the gas coils (2 screws). Remove the coils and unplug the electrical connections. Connect the new coils to their respective electricl connections. Slide the nes coils back onto their respective posts on the gas valve. Replace the retainer clip, and 2 screws to hold it in place. (I then plugged the dryer back into the wall outlet to visually check the burner operation) Everything worked fine so I then replaced the front panel.
I removed the discharge duct from the back of the dryer. Then, I removed the screws on the back of the dryer and the back itself. This exposed the cycling thermostat. I removed the screw holding the thermostat. I took the wires off the defective thermostat and reinstalled them on the new thermostat. Then, I reassembled in reverse order.