Enter the code USA15 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on July 1 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Gas dryer would not heat - pilot lit briefly then went off
Same as others. 1. Unplug dryer from power source 2. Use nut driver to remove two front screws at bottom of dryer 3. Disconnect cable connected to Secondary Coil (this is the coil towards the rear of the dryer) 4. Use angled phillips screw driver to loosen screws holding cap on top of the two coils. (Angled tool not required but seemed easiest to me) 5. Slide top cap back towards lock screw to allow coil to be lifted out 6. Remove and replace secondary coil 7. Replace cap, tighten screws to lock in place, reconnect cable to coil 8. Restore power to dryer, test and confirm gas flame stays lit 9. Replace lower front panel on unit
PartsSelect a great resource to use for home repairs like these. My first time using site and doing this type of work, now PartsSelect my first source to go to on such items.
Just take the old parts with my tools and fix it, i did take the pulley bearing with care and put the new one, and adjust the screw on the motor base, the belt just was a little difficult but I did it, it's easy.
At the end of the drying cycle, the clothes had a bunt smell. I checked the lower compartment of the dryer and found the limit thermostat in two pieces and realized this could be the culprit. I was able to snap them together, but this did not work, therefore a new stat
First I unpluged the dryer, removed the two screws from the bottom access panel. I used a small socket to remove the screws securing the limit stat to the burner chamber, nut driver was too long. I installed the new limit stat with the two screws and attached the two leads. Plugged in the dryer and conducted a test run, burner ignited. I turned the dryer off and replaced the access panel.
Had to figure out how to open the dryer - bottom screws in front and work up, removed the drum and found the fan blade was broken. Had some difficulty removing the fanblade from the motor shaft but after that the new one was easy to install. I did need help to place the belt and drum back into place. as one person has to hold the belts on the pulley while the other adjusts the belt while putting the drum back into place.
Nutdriver, Pliers, Socket set, Wrench (Adjustable), Wrench set
4 of 5 peoplefound this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
dryer stoped working
At first i thought i had to buy new dryer, because i did not know what to do.I said, i never done this kind of repair before, well i put everything apart and notice that the idler pulley was worn out, then i said this is something that i can fix it if i get the part. I made several calls and couldn't find it. so went in internet and found it with you.
popped up top of dryer -- With pliers squeezed clips on inside of latch - - with screw driver pryed latch out -- just pused new latch in.......... Thanks to parts select for sending part sooo fast.. wife was happy.. Thanks, Dale
I removed the Drier Door and removed the Front Drier Panel exposing the Gas Valve & associated parts. I removed two (2) screws holding the Gas Valve Coils in place & replaced the 2 terminal coil, then replaced the screws, Front Cover & Drier Door. I liked the results so much, I ordered the other Gas Valve Coil and will replace it also when it arrives.
I followed the instructions found on this site. The hardest part was figuring out how to release the clamps at the front of the dryer so I could remove the top.
The key was to unbolt the clamps at the back of the dryer first, then to use a putty knife to release the two clamps at the front of the dryer that hold the top to the front.
The rest was easy by following the steps already listed on this site and removing the two front pieces, then the drum and replacing the parts. Putting it back together was simple since I placed things in order and had taken pictures with my cell phone as I went through the process.
The time I took, included vacuuming the inside of the dryer thoroughly. Now it runs like new.
My drier would start create heat,than stop heating after 8-10minutes.
After reading the many different common stories,I replaced both coils (m series).Very simply lifted up the top of driver,held by 2 snap springs and 2 lint vent screws.Removed front cover,2 screws and 2 bottom snaps,coils down on bottom left.r/r both coils,reinstalled covers and let there be heat!This website is a blessing!!
Squeaking motor, over heating, thermal switch kicking out.
Unpluged dryer from outlet, disconnected vent, positioned dryer on side, removed screws from bottom panel, pulled pannel away from dryer body to gain access to motor. Disconnected drum belt from motor pulley, disconnected wire harness from motor. Removed motor mounting bracket assembly and placed entire assembly on floor. Removed clamps and blower assembly from old motor, installed new motor and reassembled. Very easy project, hardest part requires some trouble shooting knowledge to determine the exact cause of problem.
ignitor failed to ignite gas or would fail to after first ignition.
Watched youtube video to problem shoot. Cause determined to be coils bad. Searched web found Parts Select to be easiest site to deal with and had coils for best price. Followed instructions supplied with parts. Dryer works like new.
Changed, got in aimed wrong direction-best to take a digital photo before you disassemble. Overtightened bolt and nut in assembly, it seized. Attempted to drill/grind it off, should have removed motor. Drill skipped up into motor windings. Could have replaced dryer, decided not, fixed by ordering motor, mount, nut and bolt and new belt idler. Reassembly was a snap till the gremlins hit again and I lost one of the drum glides. After a trip across town, I reassembled and it was good to go. Disassembly, use a screw driver to pry up the top, use the nut driver to remove upper front left and right screws, lift front forward and off bottom hooks. You have to release the wiring harness, it has four connectors. Use a sharpy marker and write the wire colors next to the plug-ins connectors you pull gently off and set the door aside. The second wires are two wires for the inner assembly which again need to be marked for color and then pulled loose. Pull them through the plastic hold down so they're out of the way. Use nut driver to remove four screws from inner drum holder, pry gently off dryer blower. Reaching around both sides of the blower housing find the belt tensioner, pull it to the right, push the belt out of it. Lift the drum out, up slightly over the back rollers. Set aside. Use the nut driver to remove the screws into the base holding the motor mount down, now lift the motor/blower assembly forward and pull gently loose from the dryer vent pipe. Set it up where you can work on it. Using the nut driver, take the screws off the blower housing, use a vise grip to secure the motor and use a 7/8 inch turning counter clockwise to remove the turbine. Use the nut driver to remove the screws holding the turbine housing in place, pop the motor clips off. Pull the motor off and remove the nut and bolt of the belt idler assembly using a wrench on the back and a socket wrench on the other side. Reverse order to reassemble, when tightening the idler arm tighten it to where you feel it stop but not any further. Put the belt around the drum again, get it in the previous location on the drum, feel around the drum to make sure belt isn't twisted, bring belt in from the back between the idler wheel and the vent pipe in a loop (Make sure the belt is behind the tension spring rather than in front), Tip the idler arm upward, use the other hand to slide the belt loop up over the motor pulley. One final note is this being a Maytag you might write these direction on the inside of the front panel for next time.