Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
I knockedoff the door light sensor when I dropped a frozen jug of ice
I removed the plate (recommend using a magnetic phillips head screw driver to remmove screws which are recessed). I removed the old part and pushed the new part through the hole and carefully reached in behindto attach the wires to the new part.
removed the screws/nuts; pulled the back panel off, removed the old thermostat (wires just popped apart) replaced the new thermostat (wires just popped back on) replaced the back panel and the nuts and TaDa!!
My Freezer Was Frosting Up, My Ice Maker Was Not Working ,And My Fridge Was Warm.
Had to remove all screws on rear back cover of freezer inside, unplugged refridgerator, uncliped thermostat, unpluged thermostat. Replaced thermostat with new one in the same location, and let defrost fulley. Reassembled, pluged in, and tested. All was good. But I did also replace timer at first part of the repair so I suggest you replace both at the same time.
Cooling coils would ice up and fridge would warm up
I removed the shelves in the freezer, took out the five 1/4" screws and lifted off the cover. It was a simple matter of using a blow drier to remove all the ice, then unplugging the two wires and unclipping the thermostat from the upper cooling tube. Then clipped the new one on and reconnecting the two wires.
Removed the back panel in freezer compartment with the nut-driver. Then I cut off old thermostat connections, and spliced in new thermostat connections (repairman had already replaced defrost timer, and said not to trust connectors included on wires-they failed often). Then I snapped thermostat itself onto cooler coil. So far so good, fridge is running at 35-40 degrees a week later. Thanks Parts-Select!!!
Loosened the screws all around the door. easier if you take the door off the unit and lay it on a table. Cover the table with a blanket to protect the door finish. Old gasket just pulls loose. Press the raised bead on the new gasket under the plastic strip. Corners were the most difficult. Retighten the the screws and rehang the door. It took some practice to get the bead under the plastic strip.
freezer section remove ice trays ,shelves,unplug ice tray.use 1/4 nut driver remove back panel,use hair dryer thaw ice from evap coil ,unplug tstat remove install new one.plug in ice maker,put back panel back on ,ice maker and shelves plug refridgerator back in
This did not fix the problem. Call a repairman and he cannot come until 9/11. Food is staying frozen. Alarm sounds for awhile and then shuts off for a bit.
Removed the inside evaporator coil to do inside solder job, use torch to heat solder joints on the outside drier in order to remove it and install new drier. Soldered Heat exchanger line to drier and 1/4” copper line to compressor. Wrapped with new insulation wrap. Pulled a vacuum on system and then charged with 4.4 ounces of 134a freon. Works like a champ again!