Enter the code USA15 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on July 1 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Freezer compartment iced over, food thawing,
I deenergized the refigerator, removed the storage tray, three screws that hold the ice maker, two screws that hold the lower portion of the freezer, two screws tjhat hold the back portion of the freezer. Removed the ice maker and disconnected the wire connector and ground, Removed lower portion of the freezer which allowed the back portion to be lifted out. Once the back was out the bimetal defrost thermostat was located in the upper right corner clipped to a copper line. Using an ohm meter, I found the bimetal defrost thermostat to be electrically open, ordered part from information found on part, Once part arrived I deenergized the refrigerator and replaced bimetal thermostat by cutting the old thermostat wires (pink and brown), stripping the wires back about 5/8 inch and wire nutting the replacement parts like colored wires, clipped the bimetal part on the copper tube, replaced the covers in reverse order, and reenergized the refrigerator. Testing and replacing the part took about 15 minutes, waiting for the ice build up to thaw took considerably longer.
Water leaking from under refrigerator. Initially believed leak was from filter assembly. Removed filter and shut off water supply but leak appeared at different intervals again. Large puddle of water coming out from under refrigerator. Removed back lower panel and checked for leak, but didn't find any. My wife was also checking for leak and found a crack in drip tray. Only way we could get the drip tray out was to first remove front lower panel, disconnect and remove wiring harness in front of drip tray, unbolt water filter assembly, and unbolt water solenoid unit at rear of refrigerator. Their water lines connect to filter assembly. My wife controlled the water solenoid unit to give me play as I pulled the filter assembly out as much as I could from the front. I could now wiggle the cracked drip tray out from under the filter unit. Replaced drip tray and reinstalled wiring harness, water filter unit w/new filter, and re-bolted water solenoid unit at back of refrigerator. Replaced back lower panel after turning water back on and checking for leaks. Replaced front lower panel.
The reason still had leak after initially turning off water supply was because the drip tray is used to catch the water when refrigerator goes into the defrost cycle. Since the original drip tray had cracked, water only appeared on floor after defrost cycle.
First I unplugged appliance then I remove two screws from the thermostat/light cover. I then remove two defrost timer mounting screws and all electrical connectors. Then utilizing instructions recieved with new defrost timer I ascertained which wires should go where. When I was sure I had the wires ready I connected them to the others in the appliance and plugged the appliance in to ensure that the noise was no longer heard and made sure timer was working. Everything seemed fine so I unplugged appliance and secured two defrost timer mounting screws and thermostat/light cover mounting screws and that was that.
My refrigerator ran constantly and never got cold!
On a whim I looked into what it would take to fix my garage older 2nd fridge. I was thinking I needed a new seal, but when I checked the website there was a great troubleshooter. I would have never guessed that the defrost timer was what would cause it not to ever get cold. After a fairly simple repair the freezer is colder than ever and I actually had to turn it down. The only complication was the fridge was stuck in a defrost cycle so I had to reset the timer to get the refrigerator running. Thanks so much for a super helpful site for a do-it-yourselfer like me.
At age 65 I have never attempted to repair a refrigerator, until now. It took longer than needed because I did not read these articles carefully. Please note that when you open the door and the light blinks twice, waits a second and blinks again, the optics are working fine. I ordered an emitter and receiver when I didn't need to. I sent it back, the money was refunded, and ordered the ice maker. I replaced the old icemaker by removing three screws and slipping it out of its holder.
Here is how I found out I needed the new ice maker. I took the supply line apart that runs down the back of the refrigerator. I blew through it without any trouble. This told me that the line was not frozen within the refrigerator. I put the supply line back together, and jumped the solenoid that was connected to the supply line at the bottom right of the refrigerator. My model is the side by side, so it has two solenoids. The solenoid that runs the water to the dispenser in the door was always running, so I knew if there was a problem it would be with the ice maker solenoid. So, how did I jump the solenoid. Kids, don't try this at home. I disconnected the wiring harness to the solenoid by pulling it straight out. Then I took the female end of an extension chord and placed a twelve two electrical wire with the ends stripped into the positive and negative slots. I then jumped the solenoid. Water ran to the ice maker, but there still wasn't any ice made. Since the optics and the solenoid were working it seemed to me that the ice maker wasn't doing it's part. There are easier ways to check the solenoid in this forum, but this worked for me. I saved a lot of money and the parts got here quickly.
The gooseneck on the icemaker fill tube extends out beyond the back cabinet of the refrigerator, and is easily broken. Luckily, this part is a piece of cake to replace. You'll literally spend more time pulling out your fridge and cleaning out behind it then you will replacing this part.
Shut off water supply line, and turn off ice maker (lift the metal bar in the ice bucket all the way up). Loosen the hose fitting, and remove two screws. Pull out the old tube, and slide the new one in. You may have to wiggle the tube around from the inside to get the alignment correct. Replace screws and fitting. Turn water and ice maker back on, and check for leaks. It really is that easy! It took me longer to type this than to actually replace the part.
Only one potential catch. The instructions warn that you may have to cut the new tube to match the length of the old tube, so make sure you compare the length of the old and new tube. I didn't have to to do anything - the replacement part was the exact same length of the original. If by chance you do need to cut the tube, you'll need small saw of some sort, such as a coping or hack saw.
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one. But Parts Select is a great place to order from. Thank you.
1. Removed the cardboard cover. 2. Removed the terminal block and unplugged the old motor. 3. Removed three screws that held old motor to the bracket. 4. Removed the fan blade from the old motor. 5. Installed the fan blade (after cleaning) to the new motor. 6. Crimped on new wire terminals onto the leads on the new motor. 7. Installed the new motor using the fasteners provided. 8. Plugged the new motor wires onto the proper terminals in the terminal block. 9. remounted the terminal block. 10. reinstalled the cardboard cover.
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation. I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill. Done Total time of ice maker water leak repair and fan replacement about 1 hour.
Parts went right into place as the pictures showed and was working again in about 30 minutes. The only thing that wasn't working was the ice took forever to make, but solved that problem by turning up the temp in the freezer.
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
Unplug Remove entire back panel (both chipboard and metal fan grill) Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black) Unplug both fan wire connects from circuit block to release the fan power cable. Remove the fan mounting plate Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades Unscrew motor from brackets - note alignment of motor on brackets Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire) Connect new plug wire to the circuit block keeping wires connected to the proper terminals Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser Plug wire harness into motor and re-mount fan mount plate Reattach fan blade and secure using blade mount kit Replace back panels
The refrigerator leaked water every time the ice maker filled.
The problem was discovered to be a cracked fill tube head, This part extends behind the refigerator and is VERY vulnerable to breakage when the box is pushed backagainst a wall space! Placing a shim under the vertical part of the fill tube fixed the problem even without replacing it with the new part. So, now I have a spare!
I wasn't sure the kit included the part I needed from the pictures, but it did. The part slipped over the flat plastic bracket attached to the right freezer wall and the shelf fit over it. No tools required.