Fridge Air On, Not Cooling
Previous issue with this refrigerator and I figure after the Hot summer we've had in TX that it overworked itself this summer in the garage! Caught this one before all was lost as it started it's not cooling cycle on a Sunday. Ordered the identical Relay&Overload from Parts Select, 2 days later I'm back to chilling the beer again! Super service with diagrams and specs. Very glad parts select is around!
Parts Used:
Compressor Relay and Overload
  • Robert from Austin, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
75 of 180 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noticed fridge not cooling as it should
Removed the lower back panel (10 small screws)Found the condenser motor froze up and not moving air across the cooling coils.So I got a small table fan and set it behind the fridge and it kept the fridge cooling for 3 days till the new fan motor arrived. Removed 3 small screws holding the fan motor in the bracket and unpluged the wiring harness.Removed the fan from old motor and used it on the new motor.Replaced the fan in the bracket and plugged the wiring harness back in. Worked great. Very easy.Did not have to empty fridge because table fan kept coils cool. Ordering part was easy and shipping fast.Great job guys!!
Parts Used:
Condenser Fan Motor
  • Robert from Franklin, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
21 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
compressor didnt turn on
changed the starter connected to the compressor
Parts Used:
Capacitor
  • gerardo from el monte, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
24 of 41 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light inside fridge was flickering and clicking
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok
Parts Used:
Refrigerator Door Switch
  • bill from escondido, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
20 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
front roller wheel broke
its not that hard to replace. may need help to tilt fridge on one side so you can get to the bottom to remove wheel.Had to undo all four corner screws/bolts to loosen bottom section and slowly pull out base frame which holds the 4 wheels. this frame is also holding the compressor and fan so be careful.replace wheel and slowly put frame back to position and screw back bolts. pull back fridge to upright position. leave unplugged for a day or two to allow gas to come back to normal level as we had tilted it.plug it back and it works.
thanks
Anoop
Parts Used:
Front Roller
  • Anoop from Diamond Bar, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
19 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water was leaking down from freezer section to bottom part of unit
First, unplugged the refrigerator. Then removed bottom plastic liner of the freezer, 2 screws with 5/16 nut driver. At this point the ice maker had to be removed 3 screws, two on the upper part and the other under the ice maker. Now the back wall of the freezer section was removed by unscrewing 2 screws with the nut driver. This gave me access to remove the defective clip-on Bimetal defrost thermostat. It was located in the upper right corner on the back wall of the freezer. Cut off the 2 wires from the bad part( one pink the other brown)then used wire nut to replace with the new part and matched wires from freezer to new part( pink to pink and brown to brown) and clipped the part in one section of the coil. ( where the bad part was located) Put all back in place. And so far no more water leak inside the fridge.
Parts Used:
Bimetal Defrost Thermostat
  • Eric from miami, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
13 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer compartment iced over, food thawing,
I deenergized the refigerator, removed the storage tray, three screws that hold the ice maker, two screws that hold the lower portion of the freezer, two screws tjhat hold the back portion of the freezer. Removed the ice maker and disconnected the wire connector and ground, Removed lower portion of the freezer which allowed the back portion to be lifted out. Once the back was out the bimetal defrost thermostat was located in the upper right corner clipped to a copper line. Using an ohm meter, I found the bimetal defrost thermostat to be electrically open, ordered part from information found on part, Once part arrived I deenergized the refrigerator and replaced bimetal thermostat by cutting the old thermostat wires (pink and brown), stripping the wires back about 5/8 inch and wire nutting the replacement parts like colored wires, clipped the bimetal part on the copper tube, replaced the covers in reverse order, and reenergized the refrigerator. Testing and replacing the part took about 15 minutes, waiting for the ice build up to thaw took considerably longer.
Parts Used:
Bimetal Defrost Thermostat
  • Lawrence from New Bern, NC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
12 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Suspected fan failure
I pulled the refer from the wall, disconnected the power and removed the cardboard cover at the base. Using a vacuum and compressed air, I cleaned it thoroughly.
I used a screwdriver to lift the locking tab on the 3-wire connector and removed it. The best way to get the three bolts off was with a 1/4" drive ratchet and go to the std nutdriver handle when they were loose. The fan came out carefully with the blade. I removed the blade nut with flat nosed pliers, cleaned it and placed it on the new motor. I replaced the motor and installed the screws. On a do-over I would install onew screw in each hole at least halfway to get the threads started/ threaded. After that the connector slipped in and I spun the blade to check for interference. The blades can be slightly bent, but use of nut tension can also slightly adjust fan alignment as it's tight to the housing.
That's it
Parts Used:
Condenser Fan Motor
  • Don from Oregon City, OR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The fan wouldn't run as needed. The top of the refrigerator was really hot.
My husband took the old motor out by taking the screws out. Then, he unplugged the fan. We searched your site for the part. With the pictures on the site, we were able to match the motor exactly. The delivery was really fast. When we received the part, he installed the fan and plugged in the power connector. We have replaced refrigerator fans before but anyone can do this with no experience. Just follow the instructions and you're all set.
Parts Used:
Condenser Fan Motor
  • Teresa from Moneta, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
12 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
There was no light on in refrig area
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
Parts Used:
Refrigerator Door Switch
  • Lori from Chuluota, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
socket melted with bulb in it.
plastic warped in ,spaced out and, the socket snapped back in place.
Parts Used:
Light Socket Kit
  • martin l. from JACKSONVILLE,, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Didn't know if I needed Left or Right.
The item is listed as R, meaning right hand side. If you need it for the left hand side, simple turn it over. It is designed to work on both sides of the door.
Parts Used:
Door Shelf End Cap - Left or Right Side
  • Joyce from Kerrville, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water collecting under the vegatable drawers
I replaced the bi-metal thermostat. Very easy fix. It took a couple of days and the water stopped collecting at the bottom.I am very pleased with the web site.
Parts Used:
Heater, Defrost
  • Gary from BILLERICA, MA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The after market 4 yr old motor was making a wierd noise.
Removed back panel and removed the motor put new quick disconnect on and tapped the mounting holes. Removed and cleaned fan blade from old motor and put on the new motor. Mounted motor plugged it in and replaced panel.
Parts Used:
Condenser Fan Motor
  • Marcus from St Petersburg, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
9 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light not working in fridge
It was so easy!

Thanks for the rush to my home on the part.

I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!

Easy!

And I am not Mr. Fix-it!
Parts Used:
Refrigerator Door Switch
  • Michael from East Meadow, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!