Dryer would only heat cycle once
I removed the two screws holding the front panel to expose the lower works and verified the heating cycle failure. After a check of the vent system, checking the sensors for continuity and coils for resistance, I retired to the 'net for support. Accepting the general consensus that the most frequent, common and likely failure to be the coils, I rechecked them with the meter and found the two pronged coil to have significantly more resistance than the three prong coil. That was enough evidence to point to the coils. While I waited for the part to arrive, I replace the vent ducting. When the parts arrived I removed the two Phillips screws holding the coils, removed the old ones, installed the new ones, replaced the bracket, put the front cover back on and in less then ten minutes clothes where drying.
Started out taking the back off, then found online that access is from the front and much easier to get to. Simply pop the hinges in the back of the top panel and then the front of the top is popped off. From there, it is easy to remove the old belt, clean the innards (found 31 cents) and replace the new belt. It was a little disconcerting to see the idler pulley laying loose inside, but the diagram showed exactly how to put it back in place, with the new belt keeping it in place.
The new lint filter fits perfectly,however because the handle is much larger than the original it does not allow the filter to close completely...causing a small amount of lint to acummulate on the dryer top.
I did NOT have to repair the latch on the actual door, just the small metal piece that it hooks on (on the dryer itself) and it took about 10 seconds to.....do it myself. Just used needle nose pliers so squeeze the piece together and fit it in. thanks
The dryer heated up for a few minutes and then cooled down.
1 Unplug power. 2. Remove the front of the unit by removing the two screws at the bottom of the front panel. Front dryer panel will swing out from the bottom and then the clips will release the top of the panel, careful not to disconnect the dryer door switch. ( can be unplugged to remove the front panel out of the way.) 3. Looking inside the unit on the right side you will see the gas value. On top of the gas unit you will see two small coils the coil closest to the burner has two leads on it. Remove the two screws to get to the coils, remove the medal plate, remove the connector then lift off the secondary coil. Replace and test. You can test unit with the front panel off. (be careful). If no heat, check that the Flat Style igniter is glowing. (ohm out both coils) before ordering parts. Intermittent heat problems. I replaced the secondary coil, it did ohm out o:k but it had swollen and was very tight on the shaft.
First I took the front of the dryer off then located the igniter. It only required removing two screws, removing old igniter, replacing with new igniter, and replacing the two screws.. While I was replacing the igniter I took the drum out and throughly cleaned the inside. Lucky me, I found 85 cents on the floor of the dryer. I am 65yrs old, married and mother of two. This was easy to do and sure saved money. I reccommend others try to do repairs for themselves and using PartSelect was less expensive too.
The dryer would start to heat then the heat would stop
I changed out the cycling thermostat and the high limit thermostat. Mainly because that was what my research indicated was the problem. I then found some more information online that indicated the gas solenoid valves were bad. I ordered them from you and replaced them. The problem was fixed.
In order to replace the valves you need to remove the top panel. Two screws at the top of the front door assembly hold it on. Remove the screws, lift up on the front panel door assembly and move it to the side. The drum will rest in place. In the lower left corner, under the drum, you will see the solenoids. Two screws attach a plate that holds down the solenoids. Take the hold down plate off, disconnect the control wires attached to the solenoids and lift out the solenoid/control valves. To assemble everything, work backwards to the start. Good Luck
dryer would get hot for a while, then quit heating
After reading about other people with this same problem I took a chance that this would be what was wrong with my dryer.I took off the front cover of the dryer by removing two screws. I located the faulty coils and simply plugged in the 2 new coils Tah-dah Probably coud have been done without even removing the front panel, but since it was off I vacuumed out the lint ( actually my husband did all of the above, but I tell a better tale than he does and I diagnosed the problem and ordered theparts)
actually i found your site before i even looked at the dryer,thats how i knew to check for the thermal fuse. I ordered the part and it was on my door in 36 hours,pulled the two wires off the old fuse and installed the new,put the back cover on and it has been working ever since,thanks ( your in my bookmarks)
After looking at the schematic to see what was in line with the motor, I found the fuse as the first item. I pulled the fuse out and used a multimeter to ohm out the fuse. Upon using the meter I found that the fuse was bad. I typed into Google my part number that was on the fuse and the PartSelect Website came up as one of the choices to pick from. When the part arrived approx. two days later I installed the fuse by first unplugging the dryer and then removing the bottom panel and removing the fuse from the exhaust by using a small 1/4 inch wrench and pulling out the old fuse. I installed the wires on the new fuse and re-installed and put the 1/4 inch screw back in. I started the dryer after plugging it back in and it worked like it should have. Thank you for the part and I have recommended your website to other people already.
Intermittent or no gas ignition, HSI ignightor working
Removed front of gas dryer and cleaned all lint out. Checked HSI, and cleaned flame sensor. Split (3 terminal) gas coil terminals were intermittent. Read about 700 ohms across outer two terminals, but center terminal to either outer terminal was open (Infiniti on meter) 2 terminal coil measured about 550 ohms. 3 terminal coil should read about 700 ohms across outer terminals, and about 1.5K ohms center to outer terminals. Unscrewed index cover plate and replaced coil, 2 terminal coil was okay. Reassembled and finished 12 loads of laundry no problems at all.
My 14 year old son did it as I supervised! Pulled the dryer out on a dolly, unpluged the dyer, removed 9 hex head screws to remove the back cover, removed and replaced the thermal fuse, located next to the exhust outlet, set the cover back on, moved the dryer back in with the dolly. I had the thermal fuse over nighted to me for a total price of $35, figured I saved at least $150 on a service call by Whirpool.
First it was a process of alimination to find out why it was dropping out. After the problem was found it was just a matter of replacing the holding coil on the gas valve. Thank you fred kenney sr
(I knew the gas coils were bad, since the gas ignitor would glow brightly as the burner attempted to ignite. So I knew everything except the gas valve was operating normally.)
Unplug the electrical cord to the dryer. Remove the front access panel. Remove the retainer clip for the gas coils (2 screws). Remove the coils and unplug the electrical connections. Connect the new coils to their respective electricl connections. Slide the nes coils back onto their respective posts on the gas valve. Replace the retainer clip, and 2 screws to hold it in place. (I then plugged the dryer back into the wall outlet to visually check the burner operation) Everything worked fine so I then replaced the front panel.