The referigerator is warm, but the freezer is cold.
I noticed the coils very dusty dirty, tried brushing it clean, ended up blowing it clean. I noticed the condenser fan motor was never turning, I had power, so I ordered a new one. I actual received the evaporator motor, so I had to order the correct one. After changing it, and it started blowing right away. But my refrigerator is still warm. I do not know where the evaporator blower motor is located. I cannot make out from the diagram breakdown. HELP
Killed the power to the fridge. Then, used a small, thin screwdriver to depress the clip on the bottom of the switch and wriggled the old switch out. The two wires easily came off the contacts with pliers. Connected the wires to the new switch and snapped it into the hole--clip facing down and contacts facing up. Turned the power back on and checked the switch. Worked perfectly! Easy job.
The refrigerator was working for just 1 minute and breaks, I discovered that the fan was not working , I understood that there wsa something wrong with the condenser fan motor. I just order a new one.
The installation video for condenser fan motor helped a lot to know how to disconnect the old fan motor and connect the new one. So easy just know how to remove and put back the fan gently, observe carefully where is the center and the connector position; 15 min after everything was done and the unit works well to date.
Water line feeding ice maker was not producing ice
Take out the elbow fill tube and check to see if ice build up inside tube. Clean tube of ice build up. Replace tube back in. In my case that corrected my problem.
The hinge pin /axel for the deli lid on the end cap broke off.
I used “ Bruce from KIRKLAND, WA” instructions.
Without it, I may still be struggling to remove it. These are his notes summarized.
Remove both humidifier drawers Remove the glass shelf Remove the deli drawer and lid
To remove the end cap (either side) there is a plastic tab to push down on just over halfway back and then you can slide the front of the end cap up and out.
THE PLASTIC TAB IS THE KEY!! ---^
To install the new end cap, reverse this process.
The trickiest part is then re-inserting the deli drawer and the lid. Getting the lid onto the two axles was a bit of a struggle as the fit is very tight.
One of the light bulbs went out on my Whirlpool refrigerator.
I changed the bulb but it still didn’t work. I ordered a bulb holder and replaced it and it works properly now. It was an easy repair, remove the bulb, gently pry the bulb holder out with a screwdriver and snap the new one in.
It was useful that under the description of the part in the catalog, it showed that this part was often used to repair this issue. The service was great and the delivery was fast.
Ordered left side end cap from Parts Select. They sent me the right side end cap. Had to return the part. They did refund the part price but it cost me shipping both ways. Had to order the part from another vendor. After receiving the correct part it took 19 minutes to remove some shelves, replace the part and replace the shelves, deli drawer and deli cover. Very easy.
Everything went as planned except the cold temperature (freezer door switch located inside freezer) made deflection of the switch locking tab difficult to remove. Letting the switch warm up was not an option.
Refer lights not working, there are two lights and neither worked. Decided the switch was the problem.
The switch fix but did not fix the problem. I assumed the wires go on the same way as on the old switch. Is it possible if one light Burns out, the other will not work either?