refrigerator and freezer not cold enough
I don't know anything about repairing a refrigerator - I'm a computer tech. I noticed that the outside of the fridge was warm to the touch and the inside was not getting as cold as it should. I took the lower back panel behind the fridge off and noticed that the fan was not spinning. The local parts dealers did not have the condenser fan motor that was needed but they did say that they do go bad. I decided to order one from PartSelect.com and do it myself. Using a 1/4 inch nut driver and a flat head screw driver to pry the old motor out of the casing, I got the job done in about an hour or so. It's a relativly easy job. Besides the ouside panel screws, there's 3 screws on the inside near the fan blades you have to reach in to get. Pop out the whole assembly, unscrew the nut that holds the blades on and pry out the old motor and replace.. Try it yourself and save a couple hundred bucks!
Icecubes came out half-way, and refrooze. I figured out, that the melter does not work (HEATER in the icemaker) Voltage measured 105V no load. Studied the Internet, and folloved an advice: shorted the back wire and the blackwire with white stripes.these go to relay contacts. It seems, that the relay contacts are no good on Infrared receiver boaed. I turn off manually the icemaker, when needed
The plastic ring that is the connection between the drive motor at the back of the freezer compartment to the auger in the ice bin shattered when my wife was dispensing crushed ice.
Part selects cataglog for parts selection was very easy to use and the online service and delivery was great. When I got the part, it was not apparent on how to remove the auger so that I could insert the new connector. There were about about 8 visible screws, with star drive heads that I fortunately had a screwdriver that fit, and I could not tell if I had to remove all of them or only a couple. I ended up removing all, but still could not separate the dispenser portion which held the front of the auger from the back of the ice bin. I finally figured out that the dispenser door trip lever had to be disconnected and I almost lost it when I removed the metal clip that attached it to the outside of the ice bin when the spring loaded lever tried to unwind. I managed to hold it in place, separate the dispenser holding the auger from the rest of the ice bin and replace the connector. I them got the pieces back in place and was able to refasten the spring loaded lever and then replace the screws. If the spring loaded lever had unloaded, it would have been tricky to try to replicate the amount of turns (load) on the spring tension.
Water dispenser not flowing properly and ice cubes were hollow.
I removed the water filter located in the refrigerator and replaced it with the bypass plug. The ice cubes and the water dispenser work properly . I am pleased with the outcome especially the price was only $15 and less than 5 minutes of my time. Maytag recommends replacing the water filter every six months at $40 a filter. One can see how this will add up in time. Eventually I am installing an after market water filter in line prior to the refrigerator.
First I rolled the fridge out and unplugged the power cord. I then removed the ice bin. There was one screw to the left under the ice bin rack holding it in. After removing that screw, I could pull the rack out far enough to disconnect the electrical connector. You have to squeeze the wings b-4 you can pull the connector loose. I put the rack on the countertop, removed two screws and the solenoid with plunger came out. I replaced the old solenoid, put everything back together, and realized I probably just saved myself $300. My Wife thinks I'm a Hero again. It works fine now.
freezing of evaporator and no cold airflow to fridge side from freezer.
First i unplugged the appliance!!! Then I removed the three screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires. installed fan. Removed inside panels from back of freezer and de-frosted coils with hair dryer (20mins). CAUTION! "Mop up and dry area of exsess water before pluging appliance back in! Re- assemble panels and plug in.
The Shaft of the Auger Drive Motor Became Stripped
I removed the one nut screw holding the Ice bucket shelf then removed the Ice Auger Container. Then I lifed the Part containing the Drive Motor. I removed the electrical connection which just plugs into the fridge. Once the Drive motor and container was out of the fridge I removed 4 screws and the Drive motor was out. I disconnected 3 electrical connectors and connected them to the new drive motor. Then replaced the motor and connected the 4 screws. I then installed the yolk on the drive shaft and then put the drive motor container back in the fridge and reconnected the electrical. Installed the nut screw and I was done.
unpluged frig, removed rear cover removed 120v supply connector, removed three fan support screws.Changed fan blades to new motor unit installed fan support screws,installed 120v connector plug frig in, test fan installed rear cover .....
The Ice maker unit had to be removed and the shaft had to also be removed, which required dis-assembling the motor drive. The thickness of the shaft and the bearing fill cup prevents it from simply pushing it in place. Other than that I have Ice.
Old plastic ring was damaged due to leaking icemaker causing door to open when ice dispensed.
No tool required! Pulled out tray, emptied ice into large bowl for reuse. Pushed in and pulled from inside the coil springed auger until could get old plastic ring off and put new one on. Useing care not to apply too much pressure to ice dispensing end so as not to break housing. Have to turn auger assembly at an angle to compress enough and get old ring off. Needs a little physical strenth & care not to force plastic housing to breaking point. Worked great reused saved ice. Took less than 10 minutes