unit would not freeze
I removed all covers then removed screws from element and disconnected wires and removed it. when installing the new heater I payed close attention to the routing of thw wires to insure that the terminals were connected properly. I then replaced all covers and turned the frig on and in a couple of hour it was working great again
I removed the nuts that held the motor mount, then removed fan blade, cut the wires, and slid the motor pass the mounts and the coil shroud, Installed motor in reverse order. worked out ok.
removed lower back cover. diconnected fan ass'y electrical connection, removed fan housing (3 screws). removed fan motor from housing. cut old connector from fan and installed on new fan with wire nuts included. re-installed new fan to housing and re-installed housing to frame.
Freezer and Frig was not cooling down. The freezer side was all froze up on the coils.
Unplug the Frig and left the freezer side total defrost. Mine was so frozen up, it took about 6 hours with the door open. I had a towel in the botton to catch all the water and ice that fell.
Removed all the shelving units. There are 3 screws that hold the ice maker in place. Loosen the 2 screws above the ice maker about 3 or so turns. Then remove the screw under the ice maker completely. Then lift the ice maker off of the 2 screws that you just loosened. Then with a small flat blade screwdriver, push the plastic clip that holds the connector of wires that plug into the ice maker.
Then remove the screws that hold the back plastic cover that conseals the coil.
Now you should see the coils. There is one heater unit in the middle and one at the botton. There is a screw on each side of the heater unit that you need to take out. They are screwed into a metal bracket that is part of the coil system. Once the screws are removed, you simply remove the heater units. They are plugged in at the top of the coil system on a circuit board. Unplug them from there, (one of the spades connector was slightly bigger then the other, so I new where to plug them back in). Fish all the wire and heater untis out and you are ready to re-oinstall the new units.
Getting the wires back up through the coils was tricky, but I was able to do it.
The hardest thing was working inside the freezer unit. It is not very wide and was sometimes hard to get both hand inside to work.
The hardest part was taking out original light bulb because screws on shield where hard to unscrew after all this years . The old bulb vent out leaving neck in socket. It took narrow electrical pliers to get neck out .The generic appliance bulb did not fit and had aluminum neck ,not recommended for brass sockets in ovens.Putting new light bulb in was not the problem.
The old water valve leak required me to purchase this new complete part. After shutting off the water supply, disconnect the supply line, take out the old water valve by disconnecting the "plug" from the refrigerator, and disconnect the plastic water line going into the ice maker. Then just reconnect the new water valve by plugging it into the 2 pronged receptacle, note to be sure to write down which wire goes into which input when disconnecting the old valve. Then hand tighten the plastic tube into the valve. Next attach your water supply line into the new water valve, tighten this supply line as you would any plumbing supply line with a couple of adjustable wrenches and some teflon tape at the connection. I would also recommend at this point, if the compression fitting on your supply line was like mine a bit old, to spend a couple bucks on a new fitting and put that on the supply line, since you don't want to worry about it being a good seal at the supply line point, once the repair is done. After checking for "no leaks" reattach everything to the rear of the refrigerator (make a note of the attachment before taking out the old valve) and see if your ice maker starts to make some ice. You will hear the valve feeding the water to the icemaker if all is properly setup.
Pliers, Screw drivers, Socket set, Wrench (Adjustable), Wrench set
3 of 9 peoplefound this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The coating in the ice maker was peeling and ice not ejecting properly. The water would over flow over to the ice tray and freez.
Remove the 3 screws and disconect the plug. The wiring harnes on the new Ice Make did not match so I use the wiring harness from my old unit. I pluged the new one in and screwed in the three screws and it was ready. I did have to wait a full 24 hours before the first 8 pieces of ice eject out.
Removed rear cover to see non-operating fan - removed three mounting screws on the motor that were a challenge to access. Swapped fan from old motor onto new motor - one threaded nut on the motor shaft. Spliced new fan wires into fan wires of the wiring harness and mounted with three self-tapping screws supplied with new fan motor. Replaced rear cover and plugged it in! Now the refrigerator cools like new (1981 model side-by-side Admiral)
The first issue was to determine if the problem was with the ice maker or the water dispenser / pump. I chose to try to repair the dispenser first since there air bubbles in the plastic line. Also, the ice maker seems to have been working. There just wasn't enough water so the ice cubes were hollow.
I unplugged the power cord, , removed the cardboard backing and two bolts that secured the pump to the refrigerator. I vacumned the area so I could see around. I pulled the valve out and disconnected it from the internal power source. I disconnected the copper water intake and the plastic tubbing to the ice maker. I used a pipe cutter to take the old flanged area off. A new flange was included in the package. I used that and reconnected the copper intake and the plastic tubbing. I replaced the power source and secured the valve to the refrigerator makeing sure the plastic tubbing wasn't twisted. When I plugged the refrigator back up, the ice maker started working within five minutes.
Checked the manuals and found the needed part. Having worked with solenoids before gave me an idea that it was the defective part. The valve would open when water was needed and you would hear this gushing sound. Water supplt was okay and the ice making unit was also working. Bought the part from this website, switched the unit and now the ice maker is working perfectly. This could not have been any easier. Make sure to keep your manuals handy!