Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
old valve was not shutting off fully, flooding ice-maker, creating a glacier
Shut off water supply, removed old valve (two screws, 1/4' nut driver), disconnect electrical plug, remove water lines (adjustable wrench). Cut fitting off tube to ice-maker (new unit has a push-to-connect fitting). Replace water lines and electrical connector. Mount valve back on cabinet. Turn water back on.
The Freezer defrosted and everything on the top and the bottom spoiled
i had used your web site before and i read several problems that your readers had. i went to the back of the unit, removed the bottom cover and right there the i found the run capacitor and i chaged it. since i had only ordered this part to save money i went back and ordered the Start Device which when i took it off it was completely burned. the replacement part came labeled with 2 different compressor #, so i picked the one that i had and unpluged each wire. the part may differ from the one that it's in the unit but it worked when i pluged everything back on. it also helps to take a picture of everything before removing the wires in case you have to leave it and come back later. i hope to use this refrigerator another 10 years. thank you all for your help.
Unlug refrig or turn off refrig from its control panel On/OFF switch. For ease of work remove freezer shelve directly below the ice maker. Remove four screws from the bottom of the ice maker assembly, three that secure the ice maker and the other that holds a plastice shroud in place over the ice maker's power plug. The ice maker is now ready to be removed; it will slide forward by pushing up on left and right side of the ice maker's mounting slide rails. Once the ice maker is moved forward it is easier to disconnect its power plug (depress a locking tab on the side of the connector and pull connector apart and remove ice maker assembly. Remove and replace motor module by removing three screws and and replace with new unit. Reverse ice maker removal proceure for installation. Once installation is completed turn on Power to Refrig, Ice making should begin after a few hours.
Ice maker stopped working after less than six months
After checking all connections I determined the ice maker which had been replaced on 01/2007 stopped making ice. I had serviceman from a local company return and check the ice maker. He rinsed the ice maker under warm water, melting the ice build-up and re-installed the ice maker. I watched him do the re-installation, then waited for two days to see if the ice maker was functioning. Since the ice maker wasn't working, I called the serviceman, who in turn informed me that the replacement ice maker had increased in price from $170.00 to $274.00. That is when I contacted your web site, ordered the replacement ice maker. I was totally amazed and pleased by the fast, easy, and efficient way my order was processed and the ice maker was delivered. I followed the instructions included with the ice maker, and installed the replacement ice maker in about 20 minutes. I can't thank you enough for the great service. I only wish I had checked my computer after the first ice maker broke down and found your web site.
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
1.removed 3 nut screws-2 on top &1 on bottom. 2.unplug ref. from outlet. 3.unplug the wires from ice maker to ref. 4.remove ice maker 5.rinse new ice maker 6.plug ice maker to ref. using included wires 7.screw 2 top nut screws first then the bottom. 8.plug ref. back to outlet 9.made first ice in about 2-3 hours
Easy removal. Easy Plug and play install. Didn't even have to use the other wires. After install, put 4 oz of water into ice maker and wait....it didn't start making ice right away, but a couple hours later I heard the wonderful "ice dropping into the bin" sound. Worked great ever since.
The troubleshooting time takes about 20 to 30 minutes. After checking out the solenoid (valve water), the water line, and the electronic board (emitter/receiver) are working fine. The only thing left is the ice module. I called Partselect and talked to a sale rep to make sure I get the right part, and the lady was so helpful by sendind the picture of the part so I can review before ordering it. I received the part in 3 days ( normal shipping) and did the folowings: 1) Unplugged the power cord from refrigerator. 2) Removed the ice module by removed a 1/4" screw from under the right side of the icemaker that retains the icemaker and a “U” plastic clamp and then pull out the whole unit it from the track. 3) Unplugged the cable connected to the ice maker. 4) Using the phillips screw driver to remove the 3 screws. Carefully pulled out the ice module and installed the new ice module. 5) Put the ice maker back to the freezer, plug the cable back to the ice maker and put the clamp and tighten the nut. 6) Plugged the power cable back to the wall.
The first ice I got in an hour and a full bucket of ice in less than 24 hours. I spent less than $80 for the whole thing. Thank you so much Partselect for the great service and the stories posted, it really helped me to get it done.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Followed the video on parts page. I was worried I would brake the cover but learned from the video the right way to remove the front plate. I found the video very informing. Thank you for saving me a service call and the part cost was minimal compared to a new refrigerator .
Our ice maker had been overfilling and causing a big block of ice in the bin for some time, but it finally stopped working completely. In trying to determine the problem, I read the comments on the PartSelect website from other customers and thought I needed either a new valve or a new ice maker. I replaced both because when I took the old ice maker out, it had a lot of mineral deposits in it and looked very unappetizing. The videos on how to replace the valve and ice maker were very helpful. Other customers comments on replacing the valve were also great. The only thing I would add is that after getting the parts installed and the water line and electricity reconnected, it takes an hour or so for the ice maker to to fill. I suppose there is a temperature sensor that won't fill it until gets down to a certain point. I am very pleased with the outcome of this project on our 28 year old refrigerator.
The refrigerator light in our Kenmore fridge has been flaky for a number of years. The slightest bump would knock it out of the hole it fits into leaving the bulb dangling. Usually since we were used to it, we could avoid bumping it so it was no real problem, but a recent visitor bumped it and it once again was hanging. I decided this time, to take a serious look at it and fix the problem for real. I had options, duct tape, hot glue gun, goop...or a new part! A quick search on the internet, and I found www.PartSelect.com I entered my model # , quickly found the correct part number. The part came 1 1/2 days after I ordered it. The repair was very simple, I unplugged the fridge, removed the wires from the spade connectors on the old light socket, and attached them to the new socket. I then pushed the socket into the hole, and with new spring clips, it snapped snuggly into place. The socket came with extra wire connectors which I didn't need, the socket fits multiple brands of appliances. It also came with a bulb protector, but that wasn't needed for my fridge either. I was very pleased with the speed and ease of the repair. No more dangling light bulbs!
I pulled the refrigerator out from the wali slowly so not to damage the water line to the ice maker. Then with a nut driver I removed all the screws holding the back plate on. Being careful not to kink the water line, I used the adjustable wrench to losen the water line feed nut and the nut that goes to the line to the icemaker. Then I removed the screws holding the valve in place finished unhooking the water lines with my fingers. I then got the new valve and finger tightend the main water supply nut to the inlet side, then I pushed the plastic supply tube going to the icemaker into the valve. The new valve does not use a nut to attach the tubing it is a presure fit very easy.
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced. reassembled the pieces.