Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
The unit cycles but does not achieve proper temperature
Remove power from the unit. With short length #2 Phillips loosen and remove the two(2) screws on the control panel located center top of the refrigeration area. Slide the control panel back about 1/2 inch and allow it to dangle from its wiring harness. Pinch the locking tab on the harness connector with one hand and use the other hand to separate the two sides. A little force is required. Remove the control panel from the refrigerator and shut the refrigerator door. Examine and note the routing of the temperature probe (Silver colored flexible wire) take a picture for later reference. Remove the old and replace with new unit. route temperature probe like the replaced unit. Reverse the steps and reinstall the control panel. It is a good idea to also purchase and replace the defrost timer.
Replace the door gasket on the freezer door of my top-freezer refrigerator
Removed the door by removing the two screws holding it on. Do not try to do this repair with the door attached. Easily removed the old gasket. Getting the new one on the door was EXTREMELY difficult. I couldn't do it. After 90 minutes, I gave up and called my appliance repairman. When he arrived, he and I worked together to get the new gasket on the door. It took 2 sets of hands to do this. It still took us about 40 minutes. My repairman had a few choice words about the design of the system holding the gasket on the door. Ditto for me. So the cost of my repair was doubled because I had to pay the repairman to help me attach the new gasket. I should have just bought a new fridge.
Pulled the door off easily and noticed that the spacer on the Center hinge was ground down to nothing and that a small screw in the bottom plate of the door was half way out. This screw would catch on the cabinet Center hinge bracket and stopped the door from closing. Problem was solved by tightening the screw and putting in a new "spacer" that kept the small screws from contacting the Center hinge bracket. The freezer door now closes like new.
I order the small part and installed it myself, it was very easy with "part select". I will refer them and use them in the future. Thanks parts select.
I found instructions on the web about how to do this repair, so I ordered the part with confidence. But the instructions simply said "pull out the old switchlight". That was actually somewhat difficult as the clip on the side intended to hold the part in was stubborn. I eventually used a utility to slice off the clip. From that point, it was just a matter of plugging in the new switchlight , which was very simple.
The repair only required removing nthe old cover and installing the new one. What I was really surprised about is the time for delevery. I ordered the part on Friday morning around 11 AM and it was delevered by Fed Ex at 8:30 AM on Saturday morning. I am not sure how many locations they have, but this must have been close to Harrisburg, Pa.
The refrigerator would not stop running, resulting in frozen food in the refrigerator compartment.
After reading the trouble shooting section of the owners manual, I determined, without much difficulty, that the temp control was defective. I checked some local outlets and found the prices running from $36.00 and up. The same part from this site was around $20.00. Guess where I bought mine! It arrived in a timely fashion, and I installed it with no problem, in about 10 - 15 minutes. This was a very easy job, just remove and replace three wires snap the unit into place, and screw the cover on. Tip: I always use you tube or another source to get some instruction, just in case I'm not as smart as I think I am!