Enter the code USA15 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on July 1 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
The center slide broke at the connect tab on back
Once the part was received, it was very easy to snap the new part into place, and reinstall the drawers. No tools were required to complete the repair.
The freezer part of fridge was frosting up inside the freezer. Food was starting to thaw.
I went on Parts Select and typed in the problem, and they gave me the parts that might be the problem. So, I ordered the two parts, and put them in. Was really easy, as there are videos on parts select to help you remove the part and put the new one in. So simple. My freezer is working right now, so time will tell.
Empty the contents of the freezer.Take out the one shelf.Remove the plastic pieces covering the fan and evaporator removing 2 screws with the nut driver.Remove the metal back using the nut driver(2 screws)Remove the fan assembly from the back of the freezer.(4 screws)Remove the green ground wire from the fan assembly(1 screw) Take the fan assembly out of the freezer and remove the old fan(2 screws) and reinstall the new fan.Assemble the parts in the reverse order .Very simple and intuitive for anyone who is "handy" at all.
Refrigerator's Freezer section was warm and there was ice accumulating on the inside back panel.
Removed the interior shelves and set screw which holds the light cover in place. Next I removed the four screws that hold the back panel in place. Located the defrost thermostat and removed it from the aluminum tubing by unclipping it, just as it was illustrated in the repair video. Cut the wires and stripped the ends and then connected them to the ends of the new defrost thermostat. Connected them together with an 16-14 gauge crimp style end cap. Taped the entry point into the end cap to reduce moisture penetration. Reassembled the back panel, light cover and shelves.
Slide track on right side of chill tray, where it was held together, on the metal frame, the screw cracked the plastic.
Went to Sears, where I bought the Fridge, they could not locate the part I needed, so I went on line, and found partselect.com, entered the proper information, found the part I needed fast, ordered the part, received it in two days time, I already had the old part off, so it took less than ten minutes to replace it with the new part, works great, the people at partselect.com were great, an if needed, I will gladly order from them again.
Replaced above parts and the noise problem was not resolved. Ordered a new motor, fan blade and another set of grommets from PartSelect. The parts were delivered the next day. Took me about 15 minutes to swap the new parts in. It's been 3 days since the repair and the noise has not returned.
Temp. Sensor was under an egg shaped cover on the left side wall in the refrigerator. Remove the cover, cut the two wires to the old sensor and remove it. Connect the new sensor to the two wires using butt connectors. Replace cover and done.
Replaced top sensor in ref. and top sensor in freezer as well as defrost thermostat - works as advertised - easy fix, saved a bundle thanks to this site! Parts ordered and shipped quickly and without complications!
Refrigerator Running Warm, evaporator is not defrosting.
1. Removed and tested defrost heater, tests good. 2. Reinstalled defrost heater. 3. Removed and tested defrost over-temperature sensor, tests good. 4. Reinstalled over-temperature sensor using soldering iron, dielectric silicone grease, and heat-shrink tubing. 5. Removed the control printed circuit board and checked for blown fuse's, fuse's are all good. 6. Removed the defrost relay from the printed circuit board using soldering iron, bench tested the relay, it is good. 7. Soldered defrost relay back onto the circuit board, and reinstalled control board. 8. Removed and bench tested evaporator thermistor, the resistance is out of specification, ordered new thermister. 9. Installed new thermistor using soldering iron, dielectric silicone grease, and heat-shrink tubing. 10. Re-assembled refrigerator. 11. Installed temperature monitoring and recording instrumentation for 72 hour test. The defrost cycle is running correctly with a defrost termination temperature of around 90 deg-f. The defrost cycle ran twice while running the 72 hour test. 11. Removed test instrumentation and Put the unit back into service, The thermistor was the culprit. I bought the right part on the first shot, nice.
I followed instructions posted by experts and hands-on experienced owners on PARTS SELECT.Very helpful! Repairs was easy!.Defrost thermostat tried first,unsuccessfull then the DEFROST HEATER HARNESS next :BINGO !. Thank you PARTS SELECT ! Thank You every ones who posted their successful experiences that gave me confidence.From now on I know I can count on PARTS SELECT and its sites to solve my future headaches!
first unplug unit then pulled the inside back freezer cover off piled towels around and defrosted the the unit thoroughly. located the defroster unit tested for continuity was good so i replaced the temp sensors they were just nip off the old one and splice in the new one. also replace the defroster thermostat was the same nip and splice. *the parts shop did not find the model #i have but knowing those parts are interchangeable with all G-E models i ordered the parts
extra frost in freezer, not enough cooling in gridge
1.- ordered the thermostat replacement.2.- unplugged unit 3.- empty unit, removed racks too(freezer only) 4.- used a hot hair dryer to melt the ice,kept drying water inside the unit. 5.-used electrical pliers carefully removed damage thermostat.6.- putted on new thermostat, used standard wire connectors to keep wires together and wrapped them with black electrical tape. 7.-gentle replaced thermostat back in contact with the other pieces.8.- returned back racks and all removed pieces,drying all water from melted ice.9.- plugged it,...done