Enter the code USA15 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on July 4 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
The plastic ring that is the connection between the drive motor at the back of the freezer compartment to the auger in the ice bin shattered when my wife was dispensing crushed ice.
Part selects cataglog for parts selection was very easy to use and the online service and delivery was great. When I got the part, it was not apparent on how to remove the auger so that I could insert the new connector. There were about about 8 visible screws, with star drive heads that I fortunately had a screwdriver that fit, and I could not tell if I had to remove all of them or only a couple. I ended up removing all, but still could not separate the dispenser portion which held the front of the auger from the back of the ice bin. I finally figured out that the dispenser door trip lever had to be disconnected and I almost lost it when I removed the metal clip that attached it to the outside of the ice bin when the spring loaded lever tried to unwind. I managed to hold it in place, separate the dispenser holding the auger from the rest of the ice bin and replace the connector. I them got the pieces back in place and was able to refasten the spring loaded lever and then replace the screws. If the spring loaded lever had unloaded, it would have been tricky to try to replicate the amount of turns (load) on the spring tension.
frig got warm, compressor would not turn on, heard clicking noise
googled for answer, deduced relay/switch problem. googled again for parts, found partselect.com, ordered part. 2 days later & $70 lighter, my 8yr old Maytag was working again! Parts were good fit, instructions were decent enough. Not for inexperienced tinkerer though.
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Removed top hinge cover. With nut driver, removed the three screws that held top hinge. Gently lifted door off bottom hinge and laid door across sawhorses. Once I saw what parts were worn on bottom hinge, removed them. Was a little confused from parts diagram online to what I had in my hand and needed to put back on door. After a few minutes realized I had ordered basically a duplicate part, "closer with cup", didn't need it. With a screw driver easily replaced new parts and reassembled the door. Works great.
Automatic ice maker stopped delivering ice through the door dispenser
The driver that turns the screw broke off the ice enclosure. I removed the side panel, removed one screw underneath the enclosure, unclipped the wire harness and removed the entire enclosure.
I did one unnecessary step and removed the magnet from the housing. Better to remove the entire housing, then transfer the motor and magnet to the new housing.
I noticed that others had problems unscrewing the drive unit (which you need to do to transfer it to the new housing.) I simply held the center hub with a pair of pliers, and gave the drive one tap with a hammer. Like the other reviews, note that it unscrews opposite way.
Reassembly was quicker and easier; just undo everything you did to get the housing out of the freezer.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
The actuator rubber pad had hardened over time so that it wouldn't allow the solenoid to retract and stop the flow. To fix: Turn off fuse to fridge. Removed the screws on fountain faceplate. Remove faceplate. Unscrew fountain computer assembly (2 or 3 screws) to access the actuator pad from behind. Unplugged the computer ribbon. Replace black actuator pad.
Removed the four screws around the shaft. Removed the support nut on the underside of the enclosure. Pulled the enclosure out of the freezer. Removed the "blade" from the drive shaft - This was somewhat difficult as others have described. Needle-nose vice grips are almost a requirement or you'll never get it off. (Turn clockwise to remove it, as the threads are reversed). Attached the motor to the new enclosure with the four screws. Replaced the enclosure and screwed in the support nut on the underside. The difficulty in this whole process by far is removing the blade from the shaft. It takes a lot of force. At one point I almost gave up thinking that it was manufactured or pressed on. It finally came loose, and then the reinstall was no problem. My suggestion would be to let the motor and parts heat up to room temperature for a bit. It may help. A little spray of WD-40 may help as well.
This is an easy repair. It took me longer to remove the bins off the inside of the door and clean then up, then the actual repair. Remove the top hinge trim 1 Phillips screw. After the hinge trim is removed you'll see 3 hex screws. Remove the 3 screws. Hold and open the door half way, and lift up on the door. The door is not heavy. Use your kitchen table as a work bench. Place the door flat on the kitchen table . On the bottom of the door you'll see the "CLOSER" One screw removes it. Reverse operations and reassemble. Note: Put a little Vaseline grease on the pivot point. Thats it ... 15 minutes and your done plus you saved a $65.00 service call.
The Ice maker unit had to be removed and the shaft had to also be removed, which required dis-assembling the motor drive. The thickness of the shaft and the bearing fill cup prevents it from simply pushing it in place. Other than that I have Ice.
First I removed the top hinge cover plate. Then removed the three screws in the top hinge. I lifted the door off the lower hinge and laid the door on the kitchen counter. I removed the one screw holding the natural door closer part from the bottom of the door and installed the new part with the same screw. I then replaced the lower hinge pin with the new one. It just sets in place. I then repositioned the door and reinstalled the top hinge. the whole job took about 15 minutes after the refrig door had been emptied. The door works like new.