Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull the connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!
The light rocker switch wasnt working. I found the part on the web site. It was so easy. I used a screw driver to pop out the old one and pop the new one in. It took 5 min. Thanks!!!
Freezer temperature goes down to -20*F before compressor stops but refrigerator side remains normal 38*F and compressor makes a grunting noise while running.
Unplug ref then remove lower(freezer) panel plus trays and thermistor’s cover/holder then remove the evaps cover. I found the evaps all frozen up. Cut and remove old thermistor, strip wires 1/2 inch then cut the new thermistor wires to length and strip 1/2 inch, use the enclosed insulated crimp type connector and put back everything in the reverse order. It works great afterwards.
Popped off the control panel at the top behind the door. Found the thermistor and replaced it, cutting the wires and splicing the new one in. Immediately the warm section of the refrigerator was getting below freezing temperature readings, so the cooling vent was not opening. I put the old one back on and the temperature readings went back to being accurate. So this was not the problem. I believe now that the fan somehow is not blowing enough cold air up. So now I'll probably buy a fan motor and maybe a blade and try that. Otherwise the computer module I priced at $500 so I hope it isn't that. I replace the fan motor a few years ago already.
I initially tested the heating element and defrost thermostat using an ohm meter. the defrost thermostat was incased in ice, so I replaced it first. The refridgerator worked for about a week and then froze up again. I then replaced the thermistor and the unit is working as designed.
Water not draining to pan. It caused an ice build up under the freezer draw
Remove the grate at the back of the refrigerator. Remove the existing drawn tube. Replace the exiting drain tube with the updated drain tube. Check to see if water was draining properly. Replace the grate. Sit back and have a beer.
I followed the video provided by Part Select. I also let the refrigerator stay unplugged overnight with all the doors open. This p-trap kit has fixed the leaks out of the front of the refrigerator. There is no ice build-up in the freezer. Perfect!
Disconnect plug from wall. Insert putty knife between light switch.and trim panel , apply pressure to depress plastic spring holding switch in place. Apply a slight twist too putty knife releasing switch from trim piece. This wil expose plug connected to switch. Disconnect plug from switch. Connect new switch to plug. Insert switch into trim. Plug refrigerator into wall socket.
The door switch was broken so the interior light would not come on.
The instructions in the package were not helpful. They wanted me to cut the wiring harness and described where to cut based on the wire colors. My wires were not the same color! I removed the light mechanism using a combination of a screwdriver, putty knife, and plain old muscle with my fingers! The wiring harness unplugged easily and the new one inserted. It was easy to push the whole assembly back into the door. I spent more time looking for something to cut the wiring harness with (and never did find it) than the whole job actually took without needing to cut anything!
I had a loose fitting old condensor fan blade on my new motor.
I made a temporary repair by drilling the old blade plastic hub and put a small screw in it to hold it on to the shaft until the new blade arrived. The new blade came in within the two days I needed before Thanksgiving. I removed the old and pushed on the new. There were 8 screws on the back guard and two to hold the motor on. It was a snap. Thank you PartSelect.com The wife is very, very happy now, we had 51 coming over for Thanksgiving. :)