Enter the code USA15 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on July 1 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
No water in door or ice in frezzer
Removed the back cardboard cover and then 1 retaining screw from the back of valve. Unhooked all 3 tubes from valve (careful to remember which on went were), removed the 2 electrical connectors attached to the solenoids. replaced all the connectors and water lines onto new valve and tested for leaks then I moved back under the fridge where it was mounted and tightened retaining screw, checked for leaks then Pushed the fridge back in. Works Great!
First I determined the icemaker was the problem when it was no longer calling for water. You can hear that "whistle" for 6-7 seconds when it calls for water. Anyway, replacement was a piece of cake, but did not entirely fix my problem. I also had to flush the lines to the soloniods that allow water to flow through the filter and into the water storage tank because it was cloggged with a little piece of plastic.
Pulled the front Pull-face up off the old drawer...pushed the Pull-face down onto the new drawer--looked it over carefully and snapped it into place. Wish everything in my house were this easy to fix.
1. Turned off the cooling cycle and unplugged the refrigerator. 2. Removed all of the shelving and bottom basket. 3. Removed rear covering in the freezer section. 4. If frosted over, manually defrost coils with hairdryer. 5. Located original thermostat and after marking the wire locations cut the wires and removed the Thermostat. 6. Connected matching wires using a lighter to melt the wires together. Wrapped repaired wires with electricians tape. 7. Unable to install the thermostat in the recommended location (freezer is a tight fit) the new part was installed at the original location. 8. Replaced the rear cover and shelves. 9. Plugged in the refrigerator and set the cycle back to cooling. 10. Monitored freezer coils couple of days/weeks depending on how fast they freeze over (slots at bottom of cover) to validate if problem solved.
My fridge side had warmed up to 70 degrees but the freezer side was still cold. The coils inside had iced up. After thawing with a hair dryer, it froze back after another week. I removed the old defrost thermostat and wired the heater strip directly and turned on the defrost timer. It began melting the ice so that ruled out the heater strip being bad. I couldn't get a reading with my ohm meter on the defrost thermostat so I took a chance and bought the part. Installation was a breeze and it fixed the problem.
Top freezer took off the panel in freezer and melted the ice around coils and found the defrost thermostat and replaced with the new one. Just followed the instructions from your video on line. Freezer works just fine now. Refrigerator is 38 years old.
BOUGHT NEW ICEMAKER TOOK TWO SCREWS OUT, UNPLUGGED THE ELECTRICAL CONNECTION. REMOVED OLD ICEMAKER, PUT TWO SCREWS BACK INTO REFRIGERATOR(DON'T SCREW ALL THE WAY IN AS THE NEW ICE MAKER WILL FIT ON. HOOK ELECTRICAL CONNECTION AND ADAPTER (THAT COMES WITH IT). PUT THE DRAIN TUBE IN ITS SPOT, HOOK ICE MAKER ONTO THE TWO SCREWS TIGHTEN EM DOWN. I DID THIS RIGHT BEFORE I WENT TO A BIRTHDAY DINNER WITH MY HUSBAND, WAS ALREADY DRESSED AND READY TO GO AND I TOLD HIM ILL PUT IT IN SO WE CAN HAVE ICE WHEN WE RETURN. ENDED UP BEING A SURPRISE PARTY FOR ME AND WHEN WE RETURNED WE HAD ICE. IT WAS SO EASY EVEN A GIRL CAN DO IT!!
I was able to replace the housing by only removing the front cover, the e-ring and washer and the 3 hex-head screws. I was able to work the old housing around to get the actuator arm off and then get it properly inserted into the new housing. Attach the new housing, IMPORTANT: make sure you get the fixed-blades and spacer assembly in the slot of the housing that holds them in place, replace the e-ring and washer, check that the actuator arm operates the door properly and replace the front cover. The videos can be helpful but these shortcuts will save some time.
Remove ice drawer ,Removed front of drawer 4 screws ,Removed broken crusher 3 screws Ordered new parts reassembled replaced fix blade spacer that was broken and blade cover housing reattached front of drawer !