Frost in freezer, fridge not cold
From most posts I've read, the defrost timer was the culprit so I blindly ordered one. Easy install but did not fix the problem so I broke out the ohm meter. The only other 2 items it could be all tested good with my meter so I bypassed the defrost thermostat (per forum help...actually quite easy)and it defrosted fine, which told me I needed a new defrost thermostat. Installed fairly easy and problem gone.
Based on the website I decided it was most probably the defrost timer, and that was correct. I ordered it, watched the video, and two days later the part was at my door. Took the nut driver, removed 4 screws, then removed the old defrost timer, installed the new one, re-installed the whole plastic assembly with the four screws, and done!!! Couldn't have been easier.
Ice maker quit making cubes, instead it made a large block of ice.
Unplugged the fridge. Removed water inlet valve from fridge. Used voltmeter to test for resistance (between 50 and 150 ohms). Didn't pass the test. My original part was 218720400. I ordered part PS468507 from partselect.com. My original part had a "garden hose" coupling so PS468507 fit the bill. This part's electrical connection wasn't angled the same way as the original so we had to finagle it. Hooked the plastic refridgerator supply hose up first. Then screwed on the copper "garden hose" connection to the valve using channel lock pliers. Was careful not to over tighten. Then the fun started. The electrical connector wires were a tight fit between the copper tubing and the refridgerator frame. Did I mention that the electrical connetion wasn't angled the same as the original? My daughter got her smaller hands in there and was able to make the connection. NOTE: Because of the angling issue I was unable to screw the anchor plate to the fridge. I made sure that the valve did not interfere with the fan. Turned on the water and checked for leaks. Plugged the fridge back in and in a couple of hours we had ice cubes. Works like a charm!
Made sure water was going into valve, shut off water to valve, removed it. removed two connections, replaced with new valve, Walla, off & running. Incidentally, rec'd new valve much quicker than I ever expected.
Unplugged fridge, opened the door, used flat head screwdriver to pop off old switch, unplugged wires, plugged in new switch, popped it back in, and plugged the fridge back in. 2 minute fix.
No freezing or cold in either freezer or refridgerator - compressor did not run.
Traced issue to defrost timer ( burned compressor & element contacts). This unit is mounted next to the temperature adjustment control in the refridgerator area - right in front. Removal of plastic cover provided easy access to the timer. Unit unscrews from the mounting then unplugs. Installation is reverse of removal.
Snapped the end caps onto the existing shelf, and eased the assembly into the door slots. Light tapping with a hammer was required to fully seat the assembly into the door. All in all, a straightforward and simple repair.
Refer iced up and would not keep the bottom cool. It was 70 Farenheit inside.
I simply removed 4 screws holding the casing and then 2 more holding the timer. It was very easy. I then replaced the timer by unplugging and plugged the new one in. I replaced all the screws and the job was done. Less than 30 minutes. I was very impressed with the shipping time. When I ordered the part, I had it the next day.