Ice maker not making Ice
Unscrewed (loosen) screws lifted unit out unplugged electrical connection. plugged in unit hung on screws tightened screws and had ice in less then 1 hour. Rick
During cross country move, water valve froze and broke.
Straight forward repair. Remove the four screws holding cardboard back. Remove the 2 screws holding the valve. Unscrew the water lines and unplug the electrical connections. I would caution that it would be wise to either take a couple photos or write down the order of connection. Even though it is somewhat color coded and the water lines are different sizes, a photo removes any confusion. My old valve had threaded connections using brass nuts and ferrules. The new valve has push in connections so you need to cut the ferrules off.. When cutting off the tubing, be sure to cut square. An angled or "squished" cut will leak when pushed into the fitting. Attach the valve to the refrigerator with 2 screws and replace the cardboard back and you're finished. While you have the back off is a good time to clean the coils. I left my fridge out and back off for a couple of ice making cycles so I could check for leaks (how I know the tubing needs to be cut very square). All in all, a very easy fix.
Removed and replace solenoid manifold valve in rear of appliance using inadequate You Tube video. Removed and replaced augur motor after dismantling various housings using a seriously mistaken You Tube video. The latter video informed us that the yoke that screwed on the motor's shaft was a reversed Left Hand thread. It wasn't at all, and we struggled to figure that out. The people that make these videos leave out steps that they thunk are obvious, but aren't at all.
Refridgerator too cold...freezing food,could not turn down
First,read "how to" on the internet because the thermostat comes with no instructions and unplug refer. Second, remove food and lower rear panel. Third, pull off thermostat from tube it clips to, unhook wire harness,and cut wires.Fourth,add heat shrink tubing from store(that supplied is way too big) and connect wires with automotive connectors;shrink-seal tubing with flame.Fifth, re-install everything, and replace food.Sixth,use a thermometer to check temp and adjust controls as needed.
We love our ice here. I seem to replace the ice makers one to two times a year. Generally the ice cycle gets off for some reason and it starts making loud popping/clicking noises (gear grinding). Its easy to replace. Simply loosen two screws holding the unit to inside of freezer and disconnecting the wiring harness. Unit slide up and out. Replacement is super easy (5 mins or less). Bam! Ice!
Freezer was cooling, but refrigerator was not cooling all the time. Evaporator fan was running, so decided to try new thermostat.
Followed install instructions on utube. Once freezer was empty, back panel was easily removed, and defrost thermostat was in plain sight, and easy to replace. Hope that solved my problem. Refrigerator has been plugged in for four days now, and is cooling properly so far.
Unplug refrigerator , loosing two screws. Lift ice maker up to remove from position. Disconnect electrical connection. Reverse procedure to install new ice maker.
removed ice maker storage holder and then remove two philip screws and unplugged four pin connector. removed ice maker and installed new one . very easy to do
I followed the YTube video. The ice maker doesnot crush ice. The auger moves the ice to the dispenser. Is there a position for metal blades when assembling auger?