burned out Evaporator Fan Motor
simply removed wires from the old motor and gently lifted it out by by the metal clips - put the old bracket on the new motor, snapped on the new fan, replaced the wires, reinstalled the shield. All done in about 15 min.
Took off door to ice maker. Unscrewed 1 nut. Slid out unit. Unplugged electrical connector. Unsrewed 3 nuts from bottom of old unit & attached mounting bracket to new unit. Reconnected electric connector. Slid back in. Put screw back in. Put icemaker door back on. Turned icemaker on. Ice in 20 minutes!
ridiculous how a tiny plastic broken part required a full motor assembly replacement. that being said, i went online, found this website and easily identified the part i needed to order. i was impressed when it arrived within a couple of days. removing the old motor and replacing the new was a piece of cake...and i am NOT mechanically inclined,
The refrigerator door made a terrible bang every time it was opened.
The hardest part was unloading all the food from the refridgerator door! Once done, pry shroud off top door hinge, remove 3 screws and hinge plate. Lift door off bottom hinge. Remove one screw from bottom of door, remove and discard old lifter cam and spacer. Clean up a bit. Install new spacer and lifter cam. Tighten new screw firmly. Replace the lifter cam and spacer on bottom hinge pin (affixed to refridgerator body) using the same method. Replacing the door is easiest if 2 people do it. One person to lift and steady the door, the other has to lie on the floor and guide the door onto the hinge pin. Replace top hinge plate and screws. Snap shroud back over top hinge plate. Replace food in refridgerator. Close door. Done!
I took the cover off the control settings and found the timer. Removed two screws and replaced the defective one with the new one. Had to pay attention to directions since the timer is used in different ways and to make sure the loose wire was installed correctly (not the same way as the original ground was connected).
I called the local Amana repair man, wanted $150 for a new ice maker because they could not get the part I needed. Found Partsselect.com and the part cost $17 with shipping. They saved me over $100. The repair was very easy too, just removed a couple of screws.
Pulled close out panel exposing valve kit. Removed water lines, removed retaining screw, removed both electrical connections. Installed electrical connections on new valve, installed assembly, connected water lines. Replaced ice maker by removing three screws, unplugged connection. Installed connector on new unit , installed screws and plugged in unit. Everything worked just fine.
Cut off old nozzle. Tried electricians tape to join the old and new tubing for fishing, but tube with tape on it, wouldn't fit through hole in hinge at bottom of door. Fished nylon twine through new tube then old tube from dispenser end and was able to feed old tube out and new tube in. Fast and easy. Took more time to clean all the dust and dirt I found down under, than to make the repair.
Removed 2 control panel knobs and face plate that is snaped in place using a knife to prey it causing to snape lose. Removed 4 cover screws that gave me acess to Defrost Timer. Remove two fastining screws on timer unit. Remove electrical color coded 4 prong connector plug. Have to make sure black jumper wire on the new timer kit is connected to the correct one of the 4 prongs as to instruction sheet for my model refrigerator. Reassemble in reverse order. Bingo! Fixed.
We rolled the refrigerator out away from the wall and it was obvious where the break was located. We took out the old water spout for the ice maker and replaced the tube and the tubing from the solenoid. We turned it on and soon we had water dripping everywhere. We unloaded and defrosted the freezer which got all of the remaining ice that was stuck in there. We put everything back together. I read in some instructions in the manual that it might take 24 hours for the ice maker to reprogram itself and start producing ice. I was only about 12 hours and we had ice again and everything worked well. You really do not have to disconnect the water from the main line, the solinoid controls that part of operation and turns the water off until the ice trays are free and clear.
remove shelves in freezer compartment incl.holders(slide up to remove) Remove lamp/shield Remove panel (six phillips screws) disconnect motor pull off fan blade squeeze bracket holding motor to remove remove motor. Re-assemble (in reverse)
The part received was a straight replacement part - no modification required, just a simple remove and replace. This made the job really easy. Used the socket set to lower the front wheels to move the refrigerator, the nutdriver to remove the back cover and the valve, and the adjustable wrench to remove the water line. I had to cut the supply line tubing because the ferrule was too far up the line to make a good seal (minor leak quickly corrected with parts available in the kit - nice touch!) What took the most time was cleaning the coils and lint, etc. - hey I hadn't moved the unit in years! - but I did not include the 45-60 minutes this took in the repair time. Directions supplied were clear and easy to follow - but in my case I could have done the job without them - easy to see what needed to be done, but the stated precautions were nice.
The replacement valve was identical to the old one, so I didn't have to use any of the adapter parts sent with the new valve. This made the installation rather simple. After removing the back cover on the lower part of the refrigerator, I turned off the water and electrical supplies, and removed the water supply line to the valve. Then I removed the two screws securing the valve to the refrigerator. Next, I removed the two electrical connections from the valve, and unscrewed the plastic nuts holding the tubing to the valve. I didn't have to use a wrench to do this as they were hand tight, so when I attached the tubing to the new valve I tightened the nuts hand tight. This seemed to be sufficient and avoided the possibility of stripping the nuts. After checking for leaks, I attached the electrical connections and secured the new valve to the refrigerator. Then I attached the water supply line, but before replacing the back cover, I turned on the refrigerator, and let it cycle through it's first load of ice.