Enter the code USA15 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on July 1 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Ice Crusher Houseing cracked broke into pieces
Remove ice drawer ,Removed front of drawer 4 screws ,Removed broken crusher 3 screws Ordered new parts reassembled replaced fix blade spacer that was broken and blade cover housing reattached front of drawer !
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker. 2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,. 3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket. 4.Now take out 8 screws that hold the back panel in place and remove the back panel. 5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Removed the previous water filter. Installed the new water filter. I then filled a large glass full of water from the water dispenser several times to clear the air from the filter and lines.
Broken hinge bearing, refrigerator door, top bearing
1. Using Philips head screwdriver, remove plastic hinge cover on top of refrigerator door. 2. Remove bolts using socket wrench. 3. Lift door from bottom hinge. 4. With Philips head screwdriver remove screw holding bearing in place on bottom of door. 5. Remove old bearing. 6. Install new bearing. 7. Replace fridge door using reverse steps. 8. Enjoy your handi-work.
Ice auger not working to push the ice to the ice dispenser
Easy to remove the auger Motor and Solenoid, however, it didn't fix the problem. $300.00 into it I now have to purchase a circuit board for $382.00. Not a happy camper.
Fridge started making a loud racket. Condenser Fan Blade then disintegrated to dust and pieces. The plastic had degraded significantly.
The repair itself total time was quick and easy. Since the original fan blade blew apart, it was only a matter of putting the new one on in it's place. This can be done by feeding the blade between the cowling and Condenser coil and applying pressure to get it on the shaft.
If your fan is still on the shaft, simply push it off and extract it the same way. Then place the new one on the shaft.
In my case, since the part would take a couple days to get, and I had food both in the fridge and the freezer, I removed and unplugged the Condenser Fan Motor and the cowling frame and temporarily spliced a small fan I had into the line for the condenser motor. This kept the fridge working long enough to get the replacement part.
Side note. Direction of airflow is towards the Compressor, and draws air across the Condenser coils.
Did not repair, sensor was not located where you said, wrong sensor was sent to me, can't return oe exchange it COSTERMER SERVICE WILL NOT ANSWER MY EMAILS.
Removed ice bucket from freezer. Remove ice. Remove 2 phillips head screws from the inside front of ice bucket, and 2 fromt the bottom front to remove the front cover. Remove the E clip and washer from ice crusher shaft. Remove 4, 1/4” head screws from ice crusher housing. Unclip the selector shaft from crusher door paying attention to position.Slide housing off of shaft and discard. Install new housing over shaft and install the 4 screws. Install selector shaft into door. Install the E clip and washer onto shaft. Install front housing with the 4 screws previously removed. Refill bucket with ice and install bucket back into freezing taking care to orient the ice screw shaft into the cog in the back of the freezer as well as the door selection shaft. Test operation.