Enter the code USA15 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on July 1 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
The door activated light switch was missing.
Pulled the two wires out from the access hole in the lower part of the refrigerator. Put them in the spade connectors on the new switch, and pushed the switch into place.
Exposed evap defrosted with heat gun exposed defrost element defrost termination switch ok therminster didn’t check out the thermistor sends the signal to logic panel then run the the freezer ice machine and refer temps it took 24 hours before the system starting to show results freezer compartment 10 below ice compartment 0 degrees refer temp 37 degrees one refrigerant three different temps system is running at optimum performance 450.00 $ service call the thing with GE appliances there is no wiring diagram .thankyou parts select .ill use you on all domestic service calls.
Bad switch for door prevented interior light from coming on
Just as your video described, although due to the age of the fridge, it took a bit longer to remove the defective switch. Your video made this so simple, I can't imagine why we lived with a dark fridge for so long! I was ready to buy a whole new fridge, as repairmen are often nonexistent for small repairs. I am the biggest fan of your company & it's repair video. THANK YOU SO MUCH
Using plyers Pulled old switch down and out. Put new one in and pushed new switch up into position. The switch plugs into the contacts, no wiring needed. Worked like a charm. You saved me 200 dollars GE repair bill. Thanks
Temp. Sensor was under an egg shaped cover on the left side wall in the refrigerator. Remove the cover, cut the two wires to the old sensor and remove it. Connect the new sensor to the two wires using butt connectors. Replace cover and done.
coils were icing up and refrigerator section was warm freezer was cold
Unplugged unit and removed vented cover over compressor section. The run capacitor is a simple fix 1 Phillips head screw and 2 spade wire connectors. For the temperature sensor I had to remove all drawers and the ice maker to remove the back cover to expose the condenser. Put a bowl at the drain stem in the rear of the unit and used a heat gun to defrost the coils on the condenser. Cut the wire about 3" from the sensor end . cut about the same off the new sensor stripped the wires put shrink wrap on each wire, attached butt connecors . heat gun for the shrink wrap and reassembled everything. Simple job that took about a half hour to do both. I will monitor the fridge for a couple of weeks to see if I need to change the control board.
What an awesome site! After putting in my model number and finding the problem I was having, I simply picked the 2 parts that were most likely to solve the problem. I bought a defrost thermostat, and defrost heater. To a high certainty, they would solve my problem. They didn't however! I ended up having to buy a temperature sensor on another order a few weeks later when the problem resurfaced! My own fault. I should have bought it the first time. As others have written: the longest part of the job is defrosting the ice from the coil. One thing I did that I didn't see suggested: plug the drain hole below the coil. I put a couple towels in the bottom of the freezer and ran the hair dryer. Didn't take long. I read that the amount of water created will overflow the pan under the refrigerator, so I plugged the drain hole. Once you clean that mess up, the repair is pretty straight forward. Great site. Even through I had to make two separate purchases, I still saved a lot of money. Thanks!
Refrigerator Running Warm, evaporator is not defrosting.
1. Removed and tested defrost heater, tests good. 2. Reinstalled defrost heater. 3. Removed and tested defrost over-temperature sensor, tests good. 4. Reinstalled over-temperature sensor using soldering iron, dielectric silicone grease, and heat-shrink tubing. 5. Removed the control printed circuit board and checked for blown fuse's, fuse's are all good. 6. Removed the defrost relay from the printed circuit board using soldering iron, bench tested the relay, it is good. 7. Soldered defrost relay back onto the circuit board, and reinstalled control board. 8. Removed and bench tested evaporator thermistor, the resistance is out of specification, ordered new thermister. 9. Installed new thermistor using soldering iron, dielectric silicone grease, and heat-shrink tubing. 10. Re-assembled refrigerator. 11. Installed temperature monitoring and recording instrumentation for 72 hour test. The defrost cycle is running correctly with a defrost termination temperature of around 90 deg-f. The defrost cycle ran twice while running the 72 hour test. 11. Removed test instrumentation and Put the unit back into service, The thermistor was the culprit. I bought the right part on the first shot, nice.
compressor running and hot, refer and fridge room temp.
Watched a youtube on capacitors- though on a motor with a pulley, the symptoms were the same, motor running and pulley not turning-bad capacitor. Took a chance for a 17+ dollar part vs a new compressor. It worked.