Enter the code USA15 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on July 4 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Latch for ice box door broke off
Received replacement part. There is a cover over the ice box latch. Pried it off with a screwdriver head. Took the broken latch off replaced new latch to cover and replaced on the door.
Crisper Pan Glass accidentally dropped and crashed!!!
Search online and came across PARTSELECT website!!! this is amazing when I opened the website and see a labeled drawing, so I know what part number to order, it arrived on time and when I install it fits very well, one lesson I've learned is whenever you removed this glass in the chiller box you have to reinstall the glass properly by inserting one of the side to the insert slide of the chiller so it will not move! I'M VERY HAPPY!!!! THANKS!!!
Instructions say run capacitor is by motor, but on this frige its in the refrigerator compartment. The capacitors looks different, one square and the other long
Fridge keeps cycling on and off and a clicking sound happens every time compressor cycles.
I opened the back panel of the fridge and exposed the compressor. Unplugged existing run capacitor and installed new one with the addition of the sleeve that is stated must be installed around the run capacitor. Everything I read and on this web site says that based on these symptoms, that the problem is the run capacitor. I searched and search for a part called a start relay which plugs in to the compressor. This run capacitor plugs in to this other part which I take as the start relay.
Installing this run capacitor did not solve the problem. The fridge compressor keeps cycling on and off. Freezer doesn't keep as cold as it should.
Ice button no longer worked on our 3 year old fridge
Our local appliance company was 4 weeks out for a service call and so I Rea searched this myself with help from Parts Select. Our best guess was the control module which they shipped and had in hand within 3 days time. Turn off the breaker or unplug your fridge. There are two screws to remove under the bottom front of the touchpad/control panel, toward the outside edges. Remove screws, give it a gentle tap on top and it releases. Slide it down an inch or so and the side tabs release. Unplug the two connections for the lights and then you have two or three other connection, also easy to unplug. The control panel is attached to the rear of the touchpad by 4- star screws. Replace the old control panel with the new one and then reverse the process above to re-install and your refrigerator is ready to power up. Thanks again to Parts Select on their help confirming my diagnostics!
We broke the glass shelf above the vegetable bins, when we took it out to clean it.
I went on line, found PartSelect, located the diagram for our model, selected the part and ordered it. The part arrived in about 5 days, well packaged. We removed it from the packaging, and installed the new shelf. Extremely easy process. The exploded diagram on the web site allowed me to make sure I was ordering the right part.
The lights were on inside however the the water/ice dispenser did not work and the fridge and freezer side was not cooling
Simply take off the back panel. Remove the old run capacitor which is attached to the compressor by a white part. It pulls right off. You will have to unplug two wires. I took a pic to ensure I plugged the wires back up the correct way. Then I attached the new capacitor to the white part and put on the sleeve that was included, plugged it back into the compressor and zip tied the excess part of the sleeve. Once done plug fridge back up (always unplug electric devices when doing maintenance) to check before replacing back panel. It may take a few minutes before it kicks on.
Literally turned off the water to the refrigerator, disconnected the lines from the back and took one screw loose from the inside of the unit. Slid out old filter connection and slid in the new one and did reverse process.
1. Turned power off. 2. Removed 2 screws holding plastid plate which connected electrical wire from mullion to door (requires Torq-tip screwdriver). 3. Unplugged wire plug behind the plate. 4. Lifted up old mullion from 2 slots holding it in place to remove it from door. 5. Inserted new mullion into slots on door. 6. Connected electrical wire to plug inside door. 7. Screwed 2 screws to reattached plastic plate to door. 8. Turned power back on.
This model of refrigerator has a dual cooling system and it was the refer condenser fan that was making noise
You have to remove the shelves and drawer's along with the drawer mount. there is a wiring harness you need to unclip to remove the crisper electrical panel
There are six nuts to remove the lower panel at the back of the compartment where the lower drawer normally is. no need to completely remove the panel, you only need to get wiggle room to remove the fan at the base of the center panel.
There is a small triangular cover used to conceal the fan wiring harness on the right side of the center panel that you can use the putty knife to slip in on the center panel side to unclip and remove
Use the putty knife and slide it down both sides of the center panel that runs vertically to unclip it - at the base of this panel is where you'll find the condenser fan, you should be able to wiggle it out - there is a built in clip on the lower right side of the center panel that you can slip the wiring harness out of - for me this was the hardest part of the replacement as it was just awkward.
After it's removed slip in the new fan and seal and reassemble. I think the whole operation took maybe a half hour - 40 minutes. It's pretty easy all said and done.
Pulled out bottom crisper drawers. Removed drawer slides. Removed side plastic panels, then removed back panel which exposed the fan. Removed fan and replaced with new fan. Had to use the heat gun because there was ice buildup on left corner of rear panel. Reassembled in reverse order. There is several excellent videos on You Tube.
Turn off the electrical breaker for the refrigerator. On my unit the ice-maker was inside the left door. On the inside of that door is a plastic door where the ice bin is located. Open both doors and remove the ice bin. Behind the ice bin is the ice-maker. Beneath the ice-maker is a screw holding a plastic cover. Remove the screw and unhook the electrical connections. Next remove the screw for the ice-maker. Remove the ice-maker. Replacement is the exact opposite of removal. Couldn't be easier. Always be careful when putting the screws back. They were two different lengths and head sizes. Turn backward at first to line up the threads. If you strip out the plastic, game over. Good luck
I replaced the three sensors, 2 in the freezer 1 in the refrigerator. This was rated as the most common problem. Did not fix the problem. I then checked the ohms on the new sensors then the old sensors they were all within .5 of each other. So I got smart and went down the list of causes on their list. I emailed partselect and asked what the parts should read. They replied with that information and it turned out to be the voltage converter on the compressor. I ordered the part on friday payed for overnight delivery and it arrived tuesday. This as you can imagine makes me angry. But the part was easy to install and my refrigerator started working right away. I would advise anyone with this problem to start at the top of the problem list use a multi meter check everything on the list and only replace part or parts that don't come up to standards. This will save time and money and hopefully fix the problem the first time as you are not switching out parts and hoping that it solves the problem.