Refrigerator would begin to lose it's cool and we saw ice caking on the bacjk panel of the freezer section.
We had to empty the freezing section, remove the 4 screws that held the back panel and defrost the coils. Then with the diagram we got from the internet, we removed the defroster and easily installed the new one and put the back panel back on. We did find later that it was still icing over so I ordered the thermostat and we installed it today. It too was easy to install. We spliced the wires and hooked the new thermostat to the old wires and reinstalled the back panel. Hopefully this will solve the problem for us now.
Cams on Hinge assembly broken, door didn't close properly
I supported door with 2* 6 scrap wood. I used cedar shingles to raise door to correct height. Using a socket wrench, I removed the hinge from the fridge and the cam assembly from the door. I installed the new hinge and cam using the shims thatwere behind the original parts. I removed the 2*6 supports and the door now works perfectly.
Unplugged frige, removed top shelf, pulled broken fan blade off. Replaced with fan blade just purchased from PartSelect. Very simple repair. Orderd and recieved the right part.
Was able to pull the door up to the normal position, then blocked in place with 2 2x4's. Easily removed the hinge assemble and the door closing cam, which had broken in two. bolted on the replacement parts in 10 mionutes and the door was a good as new: peice of cake!!!
Lets start with the hard part: Convince wife to get a couple of her girl friends to go to a movie and see the Reader,after that visit a cafe or pub (remembered years ago the English Patient). Drove to get a six pack,removed the back panel-2 min, set a hair drier to position, had a couple beers , removed the defrost heater unit 1 min. replaced it 1 min. back panel1 min,enjoyed the rest of the afternoon,finished the beer Killed two birds with one stone Zoltan L Petho
When it was discovered there was a cooling problem in the refrigerator, I went to parts select web site and went through the troubleshooting section. Then I tested the defrost timer and the defrost element as directed by the web site. I then found out doing this, that is was the defrost timer. I ordered the part online and it was delivered THE NEXT DAY! I removed the bottom panel of the fridge, removed the screw holding the old timer, removed the wires, and reversed the procedure to install the new one. It has been 1 week, and everything is working great. Thank you PartSelect. I have since then recommended you to a relative who was having the same problem. Thanks again.
Removing gasket by pulling it back to expose 1/4" screws and replacing with the new one was easy. What was a HORROR- was that the new gasket doesn't seal against the door properly, and door doesn't want to close at all. to remedy this we had to put packing tape along the outer portion of the gasket all along the door to hold it donw, in order for the door to close. This is "possibly" becuase I overtightended the screws that hold the metal brace that holds down the gasket. Don't make this mistake and if you do, packing tape is the answer.
Refridgerator quit cooling because the defrost element had burned out and the refridgerator coils were totally covered with ice.
I defrosted freezer. Removed cover from back of freezer. Removed screws from element disconected wires. I connected wires to new element installed screws and reinstalled cover.
Removed the cover for the evaporater coils and let them defrost. Then took the old heating element out by removing two screws on the bottom element and two screws on the top element. Unplugged it and removed it from the unit. Then repeated the reverse of the procedure, installing the new unit, no wires to splice only one plug and four screws.
Pretty much self explanatory.Removed drawer and anything on top of glass shelf.Remove two screws holding on slide.Replace with new slide.Repeat on other side.Replace shelf and drawer.
Fresh Food section door made a click noise on closing
Since the cam riser was obviously broken I obtained a replacement. It also broke. The door hinge cam needed to be replaced also. To repair Remove the hinge cover using a #2 phillips driver. Than remove the Hinge using an 8mm socket. Turn the door upside down and, using an 8mm socket remoge the cam riser and the door hinge cam. Replace in reverse order. Be sure to inspect all parts and order all required.
First I propped up the door. Then I removed the 2 screws that hold the hinge on. AT this point you do need someone else because the door swings loose. I attached the new bracket and lowered the door. It went verey smooth. I ordered the new bracket after reading the installation stories from others who just repaced the plastic pieces. Its worth the extra money to just put on a new bracket
repair was simple removed glass shelf and removed the two screws holding rail in place. I was really amazed at the quick service that I had receiced, I ordered two of the same part and they had the instructions to send back the additional part in my email the next day. Thanks for your help.
rerfrigator side not cooling After determinating that the defrost timer was running I turned it to defrost and watched tosee if frost started to melt. When it didn't I checked the heater with ohmeter, checked OK, so the only other component in the defrost system is the thermostat. Then just a matter of cutting and splicing wires and snapping the new thermost in place