Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Old part was replaced by mfg’r. Wiring different. No drawings or any info was included to show wiring.
I was forced to call in a pro repairman. Will cost me at least $150 for part and repairman. I could have done job if instructions on how to rewire had been included.
The bulb has a plastic clear cover. That cover can just be carefully removed using a screwdriver. It's held in by a metal bracket. After you remove the cover. You'll just need to replace the bulb and then re-install the cover and bracket.
oven temp was not heating up to desired temp and using an oven thermometer to confirm
moved the range out to access back removed 5 screws from back panel removed 1 screw from thermostat installed new one replaced screws, done in 20 minutes problem solved
I changed the temperature sensor and tried again. The stove again went on temp runaway and it was suggested to replace control board which is out of stock. I will have to toss out this stove and buy new as you and no else has this part.
Stove was dropped and had broken, bent frame and adjuster feet
New ones fit perfectly. Take a minute to bend the frame straight. Then and I used oversize screws on the replacement parts as the drop had stripped out the screw holes of the frame.
The original instructions were to replace burner and plug wires back in the same plug they came from. The problem is that the plug order had changed between parts. Use a pencil to highligt the plug numbers on both new and old plugset, to fint the new plug positions. And need to reorient one of the burners to allow existing wires to reach.
I had to replace the switch on one of the large elements. It could and should have been a quicker repair if there would have been some installation/wiring instructions included with the part. Other than that the repair went well.
Surface element would stay on high no matter the position of selector knob
First, make sure power is off to range. Removed backing cover, pulled one wire off infinite switch at a time to put in right place on new switch. Easy fix.
Electric element would intermitantly go on high, even on low settings.
Slid stove out, disconnect power plug, removed top control panel with 4 screws. Unplugged two electrical connectors. removed knob and nut removing switch. Re-assembled in reverse order and test all functions.