Enter the code USA15 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on July 1 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Thawed out freezer, I recommend laying a couple old towels in freezer to soak up melted ice. Replaced old thermostat with new part. Removed 2 screws, removed back plate, unplugged 2 connectors and cut 2 wires. Crimped in new thermostat and repositioned to original part location. Reconnected plugs as I reinstalled back plate. Installed 2 screws and connected power. Works like new! Trouble shooting and part installation video is very helpful, great site!
The service manual diagram shows the 149 complete fan shroud in a vertical (upright) position. Misleading! Of course. The actual mounting of the lay in fan shroud fully assembled is in the horizontal position laying in a tray area just above the evaporator coil cage assembly. The entire shroud assembly can be installed incorrectly by the diagram and will still fit. BUT... no cold air will flow or be forced into the ice maker vent nor the refrigerator vent. I found this out the hard way by trial & error. If the drawing had shown it in the horizontal position for both removal and reinstallation... it would have saved a lot of time and headaches. Also, the diagram does not show the (2) plastic angle supports on the shroud, another scratch your head event. Parts included on drawing... 149, 5, 8, 9, 13, 14 on CTFFHS2611PF4 diagram page of service manual. ALSO, the (4) lower cabinet plate screws have to be removed, and the first left hand screw counting up to allow the next upper panel to swing out enough to lay the shroud in correctly (horizontal) on top of the evaporator coil cage. BOTTOM LINE... THE AIR FLOW HAS TO BE UP IN ORDER TO WORK PROPERLY.
Remove items on shelf, in crisper drawers and clean all items including the refrigerator bottom before replacing with new part! Looks like a new refrigerator inside now ????
The evaporator coil is behind the freezer. Remove the rack that makes the shelf and remove two 1/4” hex head screws I the back of the freezer to access the coil. I used a hair dryer to melt the ice off the coil. The thermostat clips on the refrigeration pipe to the coil. Remove the old thermostat and cut the wires at least a few inches from the thermostat. Clip the new thermostat on the pipe and strip about a 1/4” of the wire ends. The electrical connectors (provided with the new part) must be crimped to connect the wires.
Lifted old shelf out and snapped new shelf in. Took less than one minute to install. Identifying and ordering the correct part online was extremely easy due to the excellent presentation of the refrigerator and its parts. Ordered online one day and received the part the next day!