Broke light switch while cleaning
use kitchen knife to pry out. replaced switch assemble and pressed back into place. Could not have done this with out help from previous customers. Thanks
Loosen the screws on the sidewall (don't take them all the way out and drop them on the floor as I did) and remove the screw from the bottom bracket. Change out the electrical wires and the wire level sensor that does not come with the new unit. Put the new one in place and give it some time to cool down and make ice ( don't be impatient like I was and think the new unit was bad or that you replaced the wrong part)
I pulled the drive ring off of the icemaker and replaced it with the new part. Saved a $150 service call plus cost of part. It cost me a little over $11.00 and a repairman probably would have charged $30.
First I removed all the screws from the back cover. 2nd removed fan nut and fan blade 3rd removed fan bracket 4th I traced wire to the condenser and disconnected wires from wire nuts. Installed existing fan brackets to new motor kit then reconnected wire nuts to new motor cord Reinstalled fan nut and blade, reinstalled cover, plugged it in and BAM .WORKS PERF!
The freezer was making ice on the food. The Ref.'s gasket was ripped.
Emptied the freezer and removed the door. Removed the screws from the gasket and replaced the new gasket and lined up the new gasket put the door back on then the door would not close right. Fixed the problem. Now the Referator removed all the food off the door and removed the door. Did the same as freezer and the door was having trouble closing. And the gaskets were not fitting right by not fitting tight. So we have to use a heat gun to make the gaskets fit tighter on both freezer and refrigerator. It also took the two of us to handle the job.
had to saw off the shaft to get the yoke off and tap the holes for the 8/32 screws. all holes should have been tapped by the factory. Other than these problems, everything else went pretty good.
changed the light bulb still would not work so I figured it was the switch sure enough.
I took a chance and ordered a switch that is next to the top of the door. looked for how to remove it easily done in ten minutes works fine last long time.
Old ice maker leaking water and produced ice cubes with black inclusions. First, I removed old ice maker per video instructions. Transferred electrical cable, cover, and bail to new ice maker. First installation failed because I failed to make sure water tube correctly enter back of ice maker. No ice. Initially thought electrical cable wasn't firmly in place. Then I noticed frozen water dripping down back of freezer. A clue! Removed ice maker and reinstalled making sure water tube went through the hole in back of ice maker. Now the new ice maker works beautifully!
****Make are you order Capacitor & Starter relay too (we ordered separtely so had to pay shipping twice)**** Super easy just open access panel on back near compressor and remove retention clip with fingers, remove & replace both capacitor & starter, put clip and access panel back on, plug in and allow 8 hours to cool! Works like new again! Hope it goes another 10 years
freezer and refrigerator compartments not cold enough
Used the suggested problem list here to narrow down that the repair was most likely the run capacitor. Poped the new one in and I now have better control of my compartment ranges. I have a temperature gauge in each compartment. Check them every opening of the doors.
Removed the access panel on back of unit located the Run Capacitor on the compressor and removed the bad one and put the new one on and pugged refrigerator back in and it started up and works fine now