Enter the code USA15 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on July 1 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Terminal block arc'ed because a wire had become loose.
Ordered and received the terminal block. Installed it along with a new 220V power cord and the appropriate insulator . Ensured the terminals were tight with a nut driver. Reinstalled cover. Then, using the control panel, I did a function check on all the heating elements, clock, oven light, to satisfy all operational requirements. All checked good! And, I was relieved that the control panel had not been shorted out as the terminal block was due to a loose connection. Easy fix.
I pulled down the wire around the glass cover. . . Released on end of the wire from its holder being careful to not let the glass cover drop. Unscrewed the bulb and replaced with replacement. Easy, easy.
Read instuctions first Turn breaker off to stove or unplug to be sure. Remove burner and drip pans. Remove scews holding socket in place if you are doing more than one make sure you keep in same location. Raise cook top untill supports latch in. Assemble plug it comes with two types holder compare to your plug. cut wire to old plug so you have enough wire to connect back with new. Strip wire back and place shrink tubeover wires wire nut together heat with a lighter or heat gun then do remaining plugges. place back in cover and replace scews. make sure wire are not to long to get under burner when cook top lowered. Lower cook top and clean burner plug ends with a little sandpaper to make sure they make good connection. replace pans and burner. turn on breaker or plug in stove making sure the burners come on when turned on good luck g.d.
Cut the two wires approx 1 inch behind old connector and removed one screws to remove old connector, stripped approx 3/4 inch off the wires and connected them to the new wires on the new connector with wire caps and shrink wraps which came with the new connector. Replaced the old screw with the new screw and the job was completed. Be sure and disconnect power before starting!!
I just installed the new burners into the proper place and they fit This was very easy to order. Just had to find the model number which the web site told me where to find this. I am very satisfied with the service Thank You
removed back plate screw, removed two broiler screws. Disconnected wires in back plate by sliding them off of connectors. removed broiler coil and assembly. Using pliers, bent retaining hooks off of old coil, removed it and replaced it with the new coil. Reversed process.
I removed the entire burner assembly to avoid having to turn things off at the breaker - the whole assembly can be removed completely from the stove I had. Once it was out and disassembled, the toughest part was putting the new wires into the new block correctly. Once that was done, I had to select the right mounting bracket - there were 2 in the kit. Easy, just attention to detail. The rest of the instructions were easy to follow, re-doing the wires. The re-assembly was trivial, and it worked first time!
After carefully inspecting existing burner receptacles, I unscrewed them, raised and propped stove top. Determined which bracket to use from new kit and proceeded to cut and strip wires, twist ends together with supplied ceramic caps and heated shrink wrap on that junction. Works great. BTW got parts in 2 days in great shape and good directions.
I had a power serge and it burned the Plug at the termial block and melted a few wire.
After we got the part in the mail my husband put it on and shortened the wires and put new plugs on the ends of the wires and we had to get a new plug put it on and it was fixed.