Removed panel to access the interlock switches. There were two. The button on one switch was fine and the button on the other would not depress. Ran a continuity test and it failed. The switch also had a burnt smell
Remove Base Access Panel; Removed Valve Mounting Bracket & Valve; Disconnected Wire Connector; Disconnected Supply Line & distribution Hose; Reversed the Process. Piece of Cake; Part was O.E.M.Component Exact Fit; Took Longer to Write this than it took for Fix. Thanks I Will Be Back for other Parts.!
Removed door panel. Removed old door seal and cleaned seal recess. Installed new seal. Replaced door panel on door and ran a cycle to check for leaks. Readjusted door latch to correct small leak. Ran another leak test. Job complete and wife is happy!
Upper rack kept dropping from the wheels when we pulled it out
We knew roughly how we needed to put the cap on the rail, but our technique of simply forcing it in the end of the rail wasn't working. The trick is to bend the moveable part of the plastic cap inward while you're sliding it in, and it clicks right into place.
The location of the cap we were replacing was the upper back left, which made it a little tricky to reach back there and insert it, especially for a bigger guy like myself. We took the bottom rack out and my smaller wife was more easily able to lean in the dishwasher and reach back there to insert it.
Plumber had suggested trying a new gasket rather than replace the dishwasher. Ordered one and installed it. Cleaned door and installed gasket in about 30 minutes. So far it works great .... and ... cheaper than new dishwasher.
The part came in as ordered. After removing the dish rack, I loosened three 1/4" screws (two on the strainer basket and one at the base of the spray arm. I had to slide the rubber hose down and back to disconnect the base which I did by turning counter clockwise. The new one went in by reversing what I just described. Other than two of the screws being difficult to reach, everything worked fine.Thanks for your site.