Enter the code USA15 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on July 1 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Frost in the freezer. Icemaker frozen.
I called LG and followed the instructions given over the phone. The instructions couldn't have been simpler. Disconnect the appliance for several hours and then connect again. I disconnected the appliance overnight, cleaned out the freezer, and reconnected it. Problem solved. Did not need to call a repairman and did not use the clips.
Refrigerator light had a short in it and would randomly work
Unplugged the fridge. Used a screwdriver to loosen the switch. Easy to disconnect from fridge and just plugged the new switch in. Popped right back into the side of the fridge and worked perfectly.
I screwed the old one out and replaced it with the new one. A no-brainer. The thing that was so amazing was that I ordered the filter on the intrnet and it arrived the very next day!!! I was very surprised and pleased with the very quick shipping!!!
I found a crack in the pex line from the valve up the back of the refrigerator to the water filter. I could not find the correct 5/16" size line locally to replace it. A guy in plumbing at Home Depot said he always repaired them by cutting out the crack and finding a piece of clear vinyl line that would fit tightly over the cracked pex to splice in a fix with hose clamps. I did that and it was a really bad idea. The line was obviously fatigued and failing because it just cracked further up and leaked again. I then looked up and ordered the correct line (actually both the supply and return since they were available). Installing the new lines was a breeze. The pex connectors are simple to disconnect and reconnect. Wish I had done that to start with. I looked for a youtube video for the proper replacement steps but all I found was a video of a guy who cut out a crack and stuck a pex connector in to replace the cracked section. By doing that he pulled slack from the valve end of the line which didn't exist and cracked the line again. I don't know why anyone would mess with patching one of these lines. The correct parts are available, cut to the right length, and removing and replacing them at the valve and the filter is dead simple.
Uncoupled the old connector, replaced with new connector and attached supply line. Repair easy with right part, prior to ordering the right part I had tried a compression fitting and it still leaked. U-tube and others demonstrating repair assured me I was on the right path.
Tape off the light button so door alarm does not go off. Take off the clear light shield and remove the light bulbs. Be careful, bulbs may still be HOT!! With Phillips head screw driver unscrew the light plate assy. Drop it down in a comfortable position. Disconnect the connector, unscrew the thermal sensor and remove light assy. Install new light assy into light plate assy. There is no thermal senor in the new assy. Snap light plate assy back into place and install the two screws previously taken out. Install bulbs and clear cover. Remove tape from light door switches and you are done. Lights should go on and off when door buttons are pushed in and out.
Each time we've had to move we have to remove the doors from the fridge to get it thru the front door.since water and ice run thru the freezer door there are 2 tubes that connect at the bottom of the freezer door that aren't meant to be separated very often if ever.it's easier to cut the tubing on b
With alot of elbow grease and a pair of pliars we managed to get the old connector off wo cuttig the tubing as the tubing was getting to short from being cut once to many times & there was no more play in the length.Original connector was a different color and shapped slightly different than the new one so was a bit concerned that I had ordered the wrong part but it went one very easily & did not leak. We even managed to remove it again just to see if it was possible wo cutting again. it came off with no trouble.I would say the replacement part was a better fit than the original simply because we could remove it easily wo having to cut the tube!
I removed the old lamp cover and case. Discovered that the last repair person had not re installed it correctly so the case had melted from the bulbs. I Removed the screws that was supposed to hold it up, assembled the case and cover, inserted the screws and anchored them in where they belong. Problem solved!