Enter the code USA15 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on July 1 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Ice Maker broke at the begining of summer !!!!!!
The new Ice Maker Assembly arived in less than 24 hours. I was amazed that it came so fast.
I had already removed the old ice maker in order to get the modle number.
I just took two parts off of the old ice maker and quickly snapped them into place on the new ice maker. Then attached it to the refrigerator in less than 10 minutes. With in a few hours I had ice again !!!!!
It's good to note, first, that the dual water valve on Amana fridges are notorious for cracking and leaking, either due to the fridge being left in the cold (the water inside the valve freezes and expands, cracking the water valve) or from issues related to shipping. Read the reviews, here - it's a common issue, but easy and cheap to fix yourself. Here's my steps. I first turned off the water source to fridge by closing the correct valve. Next, I unplugged the fridge from electrical and from the water source line. When looking at the back of the fridge, I unscrewed the bottom left cover plate from the fridge body. After unscrewing and removing the plate, I made sure to note which lines came from which areas of the fridge and where the lines ended up at the dual water valve, and how they were routed through the plate and into the valve. The way this fridge is setup, the water source line screws into a main line that heads to the top of the fridge where the water filter is (like a "line in"). There's another line that heads back down to the bottom of the fridge (line out). The "line out" inserts into the outside plug of the dual water valve. The two lines coming out of the dual water valve are different sizes. Make sure to note which line goes to the icemaker and which line goes to the water dispenser inside the fridge. Once I knew which lines needed to go where, I grabbed my empty bucket, pulled the water lines out of the dual water valve with some pliers, and emptied the water into the bucket. After cleaning up any water splatter with my dry towels, I unscrewed the dual water valve from the plate. Once the old dual water valve was removed, I replaced it with the new valve and screwed it back into the plate. I cut off just a bit of the water line ends that were damaged due to pulling with the pliers, and then inserted them back into the correct spots on the dual water valve. I screwed the plate back into the fridge, reconnected the water source line (make sure to use some kind of water sealer tape or putty), plugged the fridge back into the electrical socket, turned the water source valve back on, and waited for leaks. No leaks! Once I was convinced there weren't any leaks, I had to bleed the water lines for about 20-30 minutes (it takes FOREVER...) by putting my bucket under the water dispenser inside the fridge and holding the water button for what seemed like an eternity - until the water was streaming steadily out of the dispenser. Voila! Good as new! Keep in mind that I didn't go through ALL the minute parts of each step - that would take too long. I'm believing that you'll be perceptive enough to catch the small things like looking at how the lines are routed into the dual water valve and where things are screwed into. Use your BRAIN, and you'll be fine. :-)
Begin by turning off the water source from the wall, next using a line wrench, remove the brass water line fitting nut from the copper water line from the wall. Next remove the second water line from the plastic push fitting by depressing the fitting to release the water line. Remove the Styrofoam insulation piece that resides between the water lines that run into the refrigerator, then pull the old filter head out. Reverse steps for installation.
The end cap is a very easy job to remove. Removed the three screws that hold the end cap in place using a 1/4 drive socket. Removed sliding rail which is affix to end cap to be reused with new end cap. Installed new end cap with the three screws and your done very easy. What made the job possible was the ability to identify the part from the PartsSelect.com web site which has excellent parts identification catalog.
Door was not closing with any positive feel and would often pop open when left door was shut.
Popped out old gasket and popped in nwe one. This is where things get interersting, the new gasket Does work as well as the one I replaced. I think the maganet is not strong enough. If anyone has had the same problem please let me know. This model ( Maytag- French door ) has been a lemon.
Lifted out the glass shelf and then removed two screws to get the right side end cap off. This side has a mechanical slide to adjust the amount of cold air into the Deli area.
You will need to carefully remove the plastic slide linkage from it's guides so that you can turn it sideways and it will then come off the end cap.
If it wasn't for that minor slowdown it would be a five minute job.
Thanks to this web site for QUICKLY getting me the part and providing info on how to do the job.
broke tab that holds pantry lid; something fell on the pantry lid and cracked the clear section of lid
The parts arrived VERY quickly.Replacement was extremely easy even though the right side end cap has the temperature adjustment it only took 15-20 minutes.
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok
Our refrigerator was too cold as the thermistor seems to have gone
It was great. We replaced the thermistor A little difficult to get to the thermistor but once we found it five minutes. My refrigerator seems happy but we will monitor it and see.
Refrigerator was stored for about 2 years and we picked it up when the owner decided to move into an apartment and no longer needed to unit (lost home to foreclosure). Brought the unit home and it worked great for about 3 days. On the third day my wife noticed a slight electrical burning smell. I did also and quickly emptied the unit and hoped for the best. The unit did indeed stop working. I fancy myself a do it myselfer but I would normally not go near electricity but thought what the heck it was free if i ruin it I would give it away. After a little research i found Partselect and they had a great design and a few stories that sounded similar so i pulled the relay capacitor for the compressor and sure enough the unit showed burn marks where the unit had shorted out. Maybe a bug got in there or water, dirt but I ordered the part. I arrived in two days which was great. I installed the part and plug the unit in and crossed my fingers. Very happily the unit clicked on and has been running great ever since. thanks Partselect, while I may not be one of your big customers I will refer anyone with appliance issues to your site first.
Removed the filter from inside the ref then disconneted the water line to filter and to ice maker on blue line just push line down then up to remove. Then pull whole assb. thru refreg. and install new one. very easy 2nd time mine went bad 1st time it coast almost $300.00 this time less than $50.00. Take your time and its fool proof.